Brand: Bürkert
Bürkert 177455 Type 8611 Universal Flow Controller Fitting Variant
Description
Overview
A process controller that reads a flow sensor, compares it with the set-point and drives a proportional valve is a classic building block in water treatment and dosing, and the Bürkert 177455 is Bürkert’s compact version of it. It is the Type 8611 universal electronic controller in the fitting-installation variant: the electronic module snaps onto an inline sensor fitting Type S030, evaluates its Hall paddle-wheel signal, and closes the loop through a PWM or PTM output. Seven Star LLC is an independent supplier serving Oman and the GCC.
The fitting is ordered separately, as is the proportional valve. The module itself provides the display, keys, inputs and outputs, and runs a PI controller that can also work as a two-point or three-point controller.
What the article number selects
Type 8611 is sold in many forms, each with its own number, and the chart in the datasheet crosses installation variant against sensor input. The Bürkert 177455 is the fitting installation with flow rate input from the Type S030 sensor fitting, controller outputs of 1 x PWM or 2 x PTM, 24 V DC operating voltage, 4 to 20 mA or 0 to 10 V set-point and process value signals and one binary input and output. Variants with an additional temperature input are 177458 (Pt100) and 177463 (ratio or temperature with a standard signal).
Specification table for Bürkert 177455
| Item | Value |
|---|---|
| Article number | Bürkert 177455 |
| Display | dual-line 8-digit backlit LCD |
| Operating voltage | 24 V DC, plus/minus 10 percent, filtered and regulated |
| Power consumption | approx. 2 W without valve and sensor |
| Controller modes | PI control, 2-point and 3-point, cascaded up to 2 binary outputs |
| Actuator outputs | 1 x PWM or 2 x PTM, 4 to 20 mA, 0 to 10 V |
| Set-point input | 4 to 20 mA or 0 to 10 V |
| Binary I/O | 1 binary input, 1 binary output (PNP, 1.5 A) |
| Sensor supply | 24 V DC, maximum 1 A; total outputs maximum 1.5 A |
| Frequency input | 0.25 Hz to 1 kHz |
| Pt100 range (where fitted) | 0 to plus 200 degrees C, error below 0.5 degrees C |
| Power supply cable | 0.5 mm2 maximum cross section, shielded, up to 100 m |
| Variant | fitting installation, flow rate input via Type S030 fitting |
Loop control in practice
The controller offers PI control with the process value from the flow fitting. The set-point may come from the keypad, the 4 to 20 mA or 0 to 10 V input or the binary input, and the output drives the valve. Cascaded binary outputs with windows and hysteresis allow limit alarms and on-off switching. This means that a single module can maintain a flow, signal when it deviates and report it to a PLC through the continuous output, which saves separate controller hardware.
How Bürkert 177455 differs from other Type 8611 variants
The chart lists fitting, wall, standard-rail and control-cabinet installation, and different sensor inputs. Against the wall variant 177454, which reads an external frequency flow signal, this one uses the internal Hall input and the matching fitting. Against 177458 it lacks the Pt100 temperature input. Against 567181 it provides the PWM outputs for valve control. This is the code to pick when the sensor is the Bürkert fitting and the valve is proportional.
Typical uses
Flow control and dosing in water treatment, filling and batching systems, cooling circuits and chemical feed lines. In the Gulf, desalination and wastewater plants use similar loops for chemical dosing and flow-proportional control. The two-line display shows set-point and measured value locally.
Installation
Snap the module on the S030 fitting, connect the multi-pin plug and the valve, and apply 24 V DC. Use shielded cables up to 100 m. Select the sensor type and flow units, enter the K factor of the fitting and run the controller in manual mode first to confirm the response direction. Then enable PI control and tune the gain and integral time while watching the process value.
Make sure the fitting is mounted with enough straight pipe upstream and downstream for stable readings, as given in the fitting datasheet.
Care
Check that the display seal and plug are intact, that cables are not loose and that the sensor is free of deposits. Record the tuning parameters in the documentation.
Cleanliness during assembly
New piping systems hold more contamination than any operating system will ever see: cutting swarf, weld spatter, thread tape fragments, paint and dust. A small valve with a narrow orifice is the first component to be blocked by it. Blow through or flush all pipes before connecting the valve, fit a temporary strainer during start-up and remove it only after the system has run for several hours. Take care not to push sealant tape into the port when wrapping threads, and wrap the tape in the direction opposite to the tightening. A clean assembly is the cheapest way to extend the life of every valve in the system.
Training and handover
When a new valve type is introduced to a plant, a short briefing for the maintenance team prevents mistakes later. Cover the article number system, how to read the nameplate, where the datasheet is stored, how to isolate and depressurise safely and what the typical failure signs look like. Provide a laminated sheet at the panel with the valve number, supply voltage and the expected behaviour on power loss. A plant that keeps this knowledge in the heads of a few engineers is vulnerable to staff changes, whereas written records and a small amount of training keep service quality constant across shifts.
Filtration guidance
A rule of thumb for small-seat valves is to filter the medium to a fineness at least as good as one fifth of the smallest passage in the valve, and often finer. For gas service, a five micrometre filter protects most miniature valves, and a coalescing stage removes oil aerosols from the compressor. For liquid service, a mesh strainer upstream of the valve is the minimum. Replace elements on a time basis and note the pressure drop across them, because a clogged filter starves downstream equipment and can lead engineers to open valves further than intended, which then causes other problems elsewhere.
Related items you may also need: Bürkert Type 6026 Direct-Acting 2/2-Way Plunger Solenoid Valve | Bürkert Type 8681 Control Head for Hygienic Process Valves | Lovato PMIB1A230 Insulation Monitoring Relay for IT Networks | All Bürkert products.
Bürkert 177455 ordering checklist
- When the Bürkert 177455 replaces an installed unit, check the existing nameplate against the code on this page before ordering.
- Every enquiry for the Bürkert 177455 is answered with a written confirmation of the code and expected lead time.
- Use the attached datasheet to check the Bürkert 177455 ratings, dimensions and connection details against your drawings.
- We supply the Bürkert 177455 as part of our controllers & data acquisition range to plants in Oman and the GCC.
- For critical duty, keeping one Bürkert 177455 as a site spare shortens downtime after a failure.
Documents and quotation
The Type 8611 datasheet, including the ordering chart and wiring, is attached. Send your RFQ with Bürkert 177455, the quantity, and also the fitting and valve you need, plus the delivery location in Oman or the GCC.
Datasheets & Documents
- Datasheet Bürkert 177455 Type 8611 Universal Flow Controller Fitting Variant Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Bürkert is a German family-owned maker of fluid control systems, headquartered in Ingelfingen, Baden-Württemberg. Christian Bürkert founded the company in 1946, and it is known for solenoid valves, process and control valves, flow and analytical sensors, and mass flow controllers. Its products serve water treatment, hygienic processing, gas handling and laboratory applications.
Seven Star LLC lists Bürkert valves and valve automation devices and supplies Bürkert solenoid valves and spare parts to plants in Oman as an independent supplier.
Bürkert company profile
| Founded | 1946, by Christian Bürkert |
|---|---|
| Headquarters | Ingelfingen, Germany |
| Ownership | Family-owned |
| Product families | Solenoid valves, angle seat process valves, positioners, flow meters, mass flow controllers |
Bürkert types listed on this page
Two types are listed. Type 6026 is a direct-acting 2/2-way plunger solenoid valve, with a stainless steel bellows that separates the medium from the coil, and as a direct-acting valve it switches without needing a pressure difference. Type 8681 is the Bürkert control head that mounts on top of hygienic process valves to pilot the actuator and report valve position to the control system. Control heads of this kind are common in food, beverage and pharmaceutical plants in the GCC.
Ordering Bürkert valves: what we need
The type number alone is not enough. Send the identification number from the label, or else the type with orifice, port connection, body and seal material, coil voltage and frequency, circuit function and pressure range. For a Type 8681 control head add the communication variant and the make and model of the process valve it sits on.
Facts checked against Bürkert's published company history, October 2026.
Browse Bürkert products by category: Solenoid Valve, Control Valves.
FAQ
Questions about the Bürkert 177455 Type 8611 Universal Flow Controller
Answers from our engineering team on installation, compatibility and integration.
01What is the Bürkert 177455?
A Type 8611 universal controller in the fitting-installation variant, reading a Type S030 flow fitting and controlling a proportional valve by PWM or PTM.
02Which outputs does the Bürkert 177455 have?
One PWM or two PTM outputs, a 4 to 20 mA or 0 to 10 V standard output and one binary input and output.
03What supply does the Bürkert 177455 need?
24 V DC with plus/minus 10 percent tolerance, drawing about 2 W without valve and sensor.
04Does the 177455 include the flow fitting?
No, the S030 inline fitting and the proportional valve must be ordered separately.
05Which variant adds a temperature input?
177458 adds a Pt100 temperature input for the fitting installation.