Brand:

Bürkert 126419 Type 6106 3/2-Way Normally Open Rocker Valve 1.2 mm

Description

Overview

The Bürkert 126419 sits at the top of the Bürkert sub-base group of Type 6106, combining the normally open circuit function with the larger 1.2 mm orifice. It is a direct-acting 3/2-way rocker solenoid valve with a 24 V DC, 2 W coil, a 16 mm wide polyamide body and FKM seals. In its de-energised state, air flows from the pressure port to the working port; energising the coil blocks the supply and vents the working port. Seven Star LLC is an independent supplier serving Oman and the GCC.

Reading this particular number

Four things define the code: circuit function D (normally open), a 1.2 mm orifice, 24 V DC at 2 W and the Bürkert sub-base interface of 16 by 27 mm. The CNOMO lateral version of the same valve is listed as 126420. All of them come with side plug contacts for form C plugs, manual override, sub-base seals and mounting screws, but without any connector, which is ordered as an accessory. The chart puts the standard nominal flows at 40 l/min from port 1 to port 2 and 47 l/min from port 2 to port 3 when measured at 6 bar and 1 bar differential pressure.

Facts at a glance for Bürkert 126419

Item Value
Article number Bürkert 126419
Circuit function D, 3/2-way, normally open
Port connection Bürkert sub-base 16 x 27 mm
Orifice DN 1.2
Nominal power 2 W
Flow QNn, 1 to 2 40 l/min
Flow QNn, 2 to 3 47 l/min
Pressure range vacuum to 10 bar
Valve body / seal polyamide / FKM
Operating voltage 24 V DC, tolerance plus/minus 10 percent
Duty cycle 100 percent continuous operation
Medium neutral gases, 5 micrometre filtering
Medium and ambient temperature minus 10 to plus 55 degrees C
Switching frequency approx. 16 Hz
Electrical connection plug contacts to DIN EN 175301-803 form C, cable plug Type 2516 or rectangular plug Type 2505 (ordered separately)
Degree of protection IP65 with cable plug Type 2516; IP30 with rectangular plug Type 2505
Width 16 mm
Optional approval ATEX / IECEx Ex ia IIC T5, T6 Gb on request (explosion-proof variant draws 0.5 W)

How Bürkert 126419 differs from other Type 6106 variants

Against the small normally open valve 126421, this one passes about 80 percent more air on the supply path and about 90 percent more on the exhaust path, and raises the pressure limit from 8 to 10 bar, at the cost of doubling the electrical power from 1 to 2 W. Against the normally closed 126411, which has identical flow and power data, the only change is the failsafe direction. This makes Bürkert 126419 the sensible choice when a larger actuator must remain pressurised after a power failure.

Practical uses

Think of clamping cylinders that must keep their grip, spring-return actuators on small valves that must stay supplied, and vacuum or purge lines that must remain active unless the controller intervenes. Many machine builders also use it as a pilot valve driving a larger air valve whose default position needs to be the pressurised one. The range from vacuum to 10 bar makes it flexible for both suction and pressure applications.

Installation

Check the sub-base for flatness and clean grooves. Place the seals, mount the valve with the two screws and connect a form C cable plug Type 2516, or a rectangular plug Type 2505 where the cabinet protects the connection. Remember the 100 percent duty cycle: in this valve, the coil is the part that will usually be powered, since the normal state of the machine will often be the valve closed. Check the local temperature around the manifold, which should not exceed 55 degrees C.

Use filtered neutral gas with 5 micrometre filtering. If air comes from a compressor with an oil-lubricated stage, add a coalescing filter ahead of the manifold.

Inspection and replacement

Valves of this kind are replaced as complete units. At intervals check that the manual override moves smoothly, that the plug and gasket are intact and that there are no signs of overheating on the polyamide body. Because it has a 2 W coil, the temperature rise is greater than on the 1 W version, and manifolds filled with such valves benefit from ventilation.

Comparing it with alternatives

If the cylinder is bigger than this valve can drive directly, the standard solution is to use the rocker valve as a pilot for a larger pneumatic spool valve. If the pressure exceeds 10 bar, other Bürkert types with higher ratings should be considered. For explosion-hazard areas, the data sheet describes an intrinsically safe variant approved to ATEX and IECEx Ex ia IIC T5, T6 Gb, with 0.5 W power, which is a separate build and must be requested explicitly together with the approval details required.

Electrical supply checks

A solenoid coil only performs as specified when the voltage at its terminals is inside the stated tolerance. Long cable runs, shared supplies and ageing power units can pull the voltage below the limit, causing slow opening, humming or failure to move at all. Measure the voltage at the plug with the valve energised, not at the power supply output. Check the polarity marking on DC coils, verify that protective earth is connected where the plug provides a terminal and look at the cable gland for ageing. A coil that runs hot is not always faulty, but one that smells of varnish or shows a darkened housing should be replaced together with the plug, because the insulation may have been damaged already.

Spare-part planning

Spare-part planning for valves works best when the plant keeps a list of installed article numbers and not just a list of types. Two valves of the same type may differ in orifice, seal material, voltage or port thread, and these differences are encoded in the number printed on the nameplate. During a shutdown walk-down, photograph each nameplate, record the number and the tag of the machine, and compare the list against the stock room. Criticality should drive stock levels: a valve whose failure stops a production line deserves a shelf spare, while a valve on a redundant branch may be ordered when needed. A short lead-time discussion with your supplier before the shutdown starts is almost always cheaper than expediting after a failure.

Related items you may also need: Bürkert Type 8681 Control Head for Hygienic Process Valves | Bürkert Type 6026 Direct-Acting 2/2-Way Plunger Solenoid Valve | DUNGS VPS 504 S04 Valve Proving System 230 V (219881) | All Bürkert products.

Before you order the Bürkert 126419

  • To avoid a wrong delivery, compare the code on the nameplate of the installed unit with the Bürkert 126419 code on this page.
  • The quotation for the Bürkert 126419 states the confirmed code and the lead time to site.
  • The attached manufacturer datasheet covers the Bürkert 126419 ratings, dimensions and installation details.
  • Delivery of the Bürkert 126419 is arranged to project sites in Oman and across the GCC, alongside the rest of our solenoid valves range.
  • A spare Bürkert 126419 on the shelf is a simple way to protect critical service from long lead times.

Documents and quotation

The Type 6106 datasheet is attached, including the ordering chart for this article number. Send your RFQ with Bürkert 126419, the quantity and the delivery place in Oman or the GCC.

Other Models in the 6106 Range

Seven Star LLC supplies models from the 6106 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Bürkert 126417 Type 6106 3/2-Way Rocker Solenoid Valve 24 V DCSolenoid ValvesView details
Bürkert 126411 Type 6106 3/2-Way Rocker Solenoid Valve 1.2 mm 24 V DCSolenoid ValvesView details
Bürkert 126421 Type 6106 3/2-Way Normally Open Rocker Valve 24 V DCSolenoid ValvesView details
Bürkert 126419 Type 6106 3/2-Way Normally Open Rocker Valve 1.2 mmSolenoid ValvesYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Bürkert 126419 Type 6106 3/2-Way Normally Open Rocker Valve 1.2 mm Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Bürkert is a German family-owned maker of fluid control systems, headquartered in Ingelfingen, Baden-Württemberg. Christian Bürkert founded the company in 1946, and it is known for solenoid valves, process and control valves, flow and analytical sensors, and mass flow controllers. Its products serve water treatment, hygienic processing, gas handling and laboratory applications.

Seven Star LLC lists Bürkert valves and valve automation devices and supplies Bürkert solenoid valves and spare parts to plants in Oman as an independent supplier.

Bürkert company profile

Founded 1946, by Christian Bürkert
Headquarters Ingelfingen, Germany
Ownership Family-owned
Product families Solenoid valves, angle seat process valves, positioners, flow meters, mass flow controllers

Bürkert types listed on this page

Two types are listed. Type 6026 is a direct-acting 2/2-way plunger solenoid valve, with a stainless steel bellows that separates the medium from the coil, and as a direct-acting valve it switches without needing a pressure difference. Type 8681 is the Bürkert control head that mounts on top of hygienic process valves to pilot the actuator and report valve position to the control system. Control heads of this kind are common in food, beverage and pharmaceutical plants in the GCC.

Ordering Bürkert valves: what we need

The type number alone is not enough. Send the identification number from the label, or else the type with orifice, port connection, body and seal material, coil voltage and frequency, circuit function and pressure range. For a Type 8681 control head add the communication variant and the make and model of the process valve it sits on.

Facts checked against Bürkert's published company history, October 2026.

FAQ

Questions about the Bürkert 126419 Type 6106 3/2-Way Normally Open

Answers from our engineering team on installation, compatibility and integration.

01What is the circuit function of the Bürkert 126419?
Circuit function D: a direct-acting 3/2-way valve that is normally open, with ports 1 (P), 2 (B) and 3 (R).
02How much air does the Bürkert 126419 pass?
With the 1.2 mm orifice the standard nominal flow is 40 l/min from 1 to 2 and 47 l/min from 2 to 3 at 6 bar.
03What is the maximum pressure of the Bürkert 126419?
The pressure range is vacuum to 10 bar, overpressure to atmosphere.
04Which sub-base interface does the 126419 use?
It uses the Bürkert sub-base; the CNOMO lateral variant is 126420.
05What coil does the Bürkert 126419 have?
A 24 V DC, 2 W coil with plus/minus 10 percent tolerance and a 100 percent duty cycle.