Brand: Bürkert
Bürkert 126421 Type 6106 3/2-Way Normally Open Rocker Valve 24 V DC
Description
Overview
Some pneumatic circuits must stay pressurised until the controller says otherwise, and for them the Bürkert 126421 is the matching choice. It is the normally open member of the Bürkert Type 6106 family with a 0.9 mm orifice, direct-acting 3/2-way operation and a 24 V DC coil of 1 W. The housing is 16 mm wide and the valve mounts on the Bürkert sub-base. Seven Star LLC is an independent supplier serving Oman and the GCC.
Normally open: what it means on a machine
In circuit function D, port 1 (pressure) is connected to port 2 (the working port) while the coil is off, and the coil closes that path and vents port 2 to exhaust port 3. A normally open valve therefore keeps a clamp, brake or holding cylinder pressurised during a power loss, which is a deliberate fail-safe choice in some machines. Conversely, a normally closed valve such as 126417 would vent the same cylinder when the power fails. Deciding which behaviour is safe for the load is a design responsibility, and it is the main reason for picking this code.
Technical table for Bürkert 126421
| Item | Value |
|---|---|
| Article number | Bürkert 126421 |
| Circuit function | D, 3/2-way, normally open |
| Port connection | Bürkert sub-base 16 x 27 mm |
| Orifice | DN 0.9 |
| Nominal power | 1 W |
| Flow QNn, 1 to 2 | 22 l/min |
| Flow QNn, 2 to 3 | 25 l/min |
| Pressure range | vacuum to 8 bar |
| Valve body / seal | polyamide / FKM |
| Operating voltage | 24 V DC, tolerance plus/minus 10 percent |
| Duty cycle | 100 percent continuous operation |
| Medium | neutral gases, 5 micrometre filtering |
| Medium and ambient temperature | minus 10 to plus 55 degrees C |
| Switching frequency | approx. 16 Hz |
| Electrical connection | plug contacts to DIN EN 175301-803 form C, cable plug Type 2516 or rectangular plug Type 2505 (ordered separately) |
| Degree of protection | IP65 with cable plug Type 2516; IP30 with rectangular plug Type 2505 |
| Width | 16 mm |
| Optional approval | ATEX / IECEx Ex ia IIC T5, T6 Gb on request (explosion-proof variant draws 0.5 W) |
How Bürkert 126421 differs from other Type 6106 variants
The only difference between this valve and the normally closed 126417 is the circuit function: both have the 0.9 mm orifice, 1 W coil, 22 and 25 l/min flow and the vacuum to 8 bar range, and both mount on the Bürkert sub-base. Its CNOMO twin is 126422. The larger normally open valve with the 1.2 mm orifice and 2 W coil is 126419, with 40 and 47 l/min and a 10 bar limit. Use this smallest normally open type when you need the fail-safe behaviour at minimal power.
Typical applications
Normally open miniature valves are used for holding clamps in packaging and assembly machines, keeping a vacuum cup supplied until released, and maintaining a purge flow in analyser cabinets during a controller fault. In oil and gas instrumentation in Oman, similar valves keep a small purge or pilot signal active unless the logic removes it. The valve can also serve in vacuum circuits, since its pressure range starts at vacuum.
Mounting and connection
The valve is supplied with side plug contacts, manual override, sub-base seals and the screws. Connectors are separate: choose a cable plug Type 2516 for IP65 or a rectangular plug Type 2505 for IP30. Fit the seals in their grooves, tighten the screws evenly and connect 24 V DC. Because a continuously energised normally open valve is in the closed state, the coil will be on for most of the time that the machine is running, so make sure that the continuous 1 W rating, the 100 percent duty cycle and the maximum ambient temperature of 55 degrees C are respected in the cabinet.
Maintenance
Because the coil may stay powered for long periods, check enclosure temperatures during the summer months and inspect the plug gasket for ageing. Keep the supply air filtered to 5 micrometres. Replacement is by whole valve, and the sub-base seals should be renewed whenever the valve is lifted.
When the machine is serviced, test both states of the valve: with the coil off the air should flow to the working port, and with the coil on it should be vented through port 3. A valve that does not follow this pattern should be replaced and the air quality checked.
Ordering information
Give the exact number, the quantity and the connector type on your request. The manufacturer also lists single and multiple manifolds for both the Bürkert and CNOMO interfaces, and these can be quoted together with the valves if you are building a new manifold. Mention if the application is in a hazardous area, because the intrinsically safe Ex ia variant is a different build with 0.5 W power and needs separate confirmation of its approvals and order code from the manufacturer’s data. For ordinary industrial atmospheres, the standard 1 W version described here applies.
Testing after installation
A simple test protocol after installation avoids surprises at start-up. First pressurise the line slowly with the valve closed and look for leaks at the threads with a leak-detection spray or soapy water. Then energise the valve and confirm full flow, listening for chatter that might indicate low voltage or excessive pressure. De-energise it and watch the pressure gauge downstream: it should hold or decay in the manner expected for the circuit function. Finally, simulate a power loss and verify that the valve moves to its safe position within the time the process requires. Record the results so that the test can be repeated after maintenance.
Quotation checklist
A complete enquiry shortens the quotation. Give the full article number, the quantity, the required delivery date and the destination. If you are replacing an installed valve, add the nameplate photograph and the tag number. Mention the supply voltage and connector type, because plugs and coils are often ordered separately. If the valve is for a project, add the project name and whether documentation such as the datasheet or a conformity statement is required with the shipment. Where an alternative number might serve, tell us whether you will accept it, so that a long lead-time item can be replaced by one that is easier to deliver.
Related items you may also need: Bürkert Type 8681 Control Head for Hygienic Process Valves | Bürkert Type 6026 Direct-Acting 2/2-Way Plunger Solenoid Valve | Moog 072-1202-6 Servo Valve, 150 l/min, ISO 10372 Size 06 | All Bürkert products.
Points to confirm for the Bürkert 126421
- If the Bürkert 126421 is a like-for-like replacement, read the full code from the installed nameplate and compare it with this page.
- For each Bürkert 126421 request we confirm the exact code and lead time in writing.
- Dimensions, ratings and connection data for the Bürkert 126421 are in the datasheet attached to this page.
- The Bürkert 126421 belongs to our solenoid valves range and can be delivered to Muscat, Sohar, Duqm and other GCC locations.
- Plants that run the Bürkert 126421 on critical service often hold a spare unit in the store.
Documents and quotation
The datasheet for Type 6106 is attached, with circuit symbols, dimensions and the ordering chart. Please send your RFQ with Bürkert 126421, the quantity, and the delivery location in Oman or the GCC.
Other Models in the 6106 Range
Seven Star LLC supplies models from the 6106 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Bürkert 126417 Type 6106 3/2-Way Rocker Solenoid Valve 24 V DC | Solenoid Valves | View details |
| Bürkert 126411 Type 6106 3/2-Way Rocker Solenoid Valve 1.2 mm 24 V DC | Solenoid Valves | View details |
| Bürkert 126421 Type 6106 3/2-Way Normally Open Rocker Valve 24 V DC | Solenoid Valves | You are viewing this model |
Datasheets & Documents
- Datasheet Bürkert 126421 Type 6106 3/2-Way Normally Open Rocker Valve 24 V DC Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Bürkert is a German family-owned maker of fluid control systems, headquartered in Ingelfingen, Baden-Württemberg. Christian Bürkert founded the company in 1946, and it is known for solenoid valves, process and control valves, flow and analytical sensors, and mass flow controllers. Its products serve water treatment, hygienic processing, gas handling and laboratory applications.
Seven Star LLC lists Bürkert valves and valve automation devices and supplies Bürkert solenoid valves and spare parts to plants in Oman as an independent supplier.
Bürkert company profile
| Founded | 1946, by Christian Bürkert |
|---|---|
| Headquarters | Ingelfingen, Germany |
| Ownership | Family-owned |
| Product families | Solenoid valves, angle seat process valves, positioners, flow meters, mass flow controllers |
Bürkert types listed on this page
Two types are listed. Type 6026 is a direct-acting 2/2-way plunger solenoid valve, with a stainless steel bellows that separates the medium from the coil, and as a direct-acting valve it switches without needing a pressure difference. Type 8681 is the Bürkert control head that mounts on top of hygienic process valves to pilot the actuator and report valve position to the control system. Control heads of this kind are common in food, beverage and pharmaceutical plants in the GCC.
Ordering Bürkert valves: what we need
The type number alone is not enough. Send the identification number from the label, or else the type with orifice, port connection, body and seal material, coil voltage and frequency, circuit function and pressure range. For a Type 8681 control head add the communication variant and the make and model of the process valve it sits on.
Facts checked against Bürkert's published company history, October 2026.
Browse Bürkert products by category: Solenoid Valve, Control Valves.
FAQ
Questions about the Bürkert 126421 Type 6106 3/2-Way Normally Open
Answers from our engineering team on installation, compatibility and integration.
01Is the Bürkert 126421 normally open?
Yes, it is circuit function D, a direct-acting 3/2-way valve that is normally open between ports 1 and 2 with the coil off.
02What flow does the Bürkert 126421 deliver?
The 0.9 mm orifice gives standard nominal flows of 22 l/min from 1 to 2 and 25 l/min from 2 to 3 at 6 bar.
03Which sub-base fits the Bürkert 126421?
It fits the Bürkert sub-base; the CNOMO lateral version is a separate article, 126422.
04Can the Bürkert 126421 stay energised continuously?
Yes, the 24 V DC, 1 W coil has a 100 percent duty cycle, within the ambient limit of 55 degrees C.
05How does the 126421 differ from 126419?
126419 is also normally open but has a 1.2 mm orifice, a 2 W coil, 40 and 47 l/min flow and a 10 bar limit.