Brand:

Viking Pump QS8124A 500 GPM Mag Drive Internal Gear Pump

Description

Overview

At the top of the 8124A range, Viking Pump QS8124A is rated at 500 GPM (114 m3/h) at 520 rpm through 6 inch ports. It weighs about 775 lb (352 kg) and is the biggest sealless cast iron internal gear pump in the Universal Product Line. The idea is the one that defines the whole series: couple the motor to the rotor magnetically, seal the liquid inside a 316L stainless canister and eliminate the shaft seal that causes most leaks on conventional gear pumps. Seven Star LLC is an independent supplier serving Oman and the GCC.

Position in the range

Ten models make up the 8124A series. The smallest, H8124A, delivers 15 GPM; the Viking Pump QS8124A delivers more than thirty times that. Only the QS has standard 180 degree ports, with 90 degree ports as an option, whereas all the other sizes have standard 90 degree ports that can be turned to any of four positions. This matters for piping layout: a QS pump with straight-through ports suits a pipeline that continues in a line, while the 90 degree option brings suction and discharge to the sides.

Viking Pump QS8124A specification

Parameter Value
Model Viking Pump QS8124A, series 8124A, sealless mag drive, catalog section 1403
Port size 6 inch (150 mm)
Nominal capacity 500 GPM (114 m3/h) at 520 rpm
Casing, head and bracket Cast iron, ASTM A48 Class 35B
Rotor Cast iron ASTM A48 Class 35B; steel ASTM A148 Grade 80-50 optional
Rotor shaft and idler pin Hardened steel, ASTM A108 Grade 1045
Bushings Carbon graphite standard; hardened cast iron or silicon carbide optional
Canister 316L stainless steel
Magnets Neodymium iron boron standard; samarium cobalt above 225 F (105 C)
Maximum hydrostatic pressure 300 PSIG (21 bar)
Maximum discharge pressure 200 PSIG (14 bar)
Temperature, standard pump 225 F (105 C)
Temperature, high temperature construction 500 F (260 C)
Viscosity range, series 28 to 250,000 SSU (1 to 55,000 cSt)
Shipping weight with valve 775 lb (352 kg)

Why Viking Pump QS8124A weighs only 70 lb more than the Q8124A

The two big models share one frame, which is why 705 lb and 775 lb are so close together. What changes is the pumping element: the QS has a larger rotor and idler and bigger ports, producing 500 GPM against 300 GPM at the same speed. Both retain the reversed circulation path, a 300 PSIG hydrostatic limit and the 200 PSIG maximum discharge pressure. If you already run Q8124A pumps, the QS offers a way to raise throughput without changing the motor speed class, though the drive power rises and the piping must be sized for 6 inch flow.

Operating limits to respect

  • Liquid temperature up to 225 F (105 C) with standard magnets; higher with samarium cobalt magnets and high temperature construction up to 500 F (260 C).
  • Viscosity from 28 to 250,000 SSU; apply the correct rated speed for thick liquids.
  • Differential pressure within the 200 PSIG limit shown in the catalog, with suction pressure kept within the canister rating.
  • Clockwise rotation gives the rated capacity; counter-clockwise gives a little less on thin liquids below 100 SSU.
  • Short dry-running periods only, for example while clearing a line.

Where the QS is installed

Because of its size, a QS pump normally serves a central transfer function: tank-to-tank movement at a chemical terminal, loading of road tankers with polyol or isocyanate, or large scale feed to a polymerisation unit. Petrochemical complexes in the Gulf use pumps of this scale for hazardous liquids. The sealless design avoids the need for a seal flush system, double seal barrier tank and leak detection, which for a pump this large can be a major capital and maintenance cost.

Handling and mounting

At 775 lb the pump needs proper lifting equipment. Fit it to a base that is designed for both pump and motor weight, level it and check the bracket foot for a soft foot before bolting down. Motor and pump should be joined by a coupling or reducer, with alignment taken after the piping is connected. Make provision for draining the casing and for flushing the pump before dismantling when the liquid is hazardous.

For Q and QS frames the catalog lists a high torque for closing the bracket, so a calibrated torque wrench is essential. Do not substitute fastener grades without checking with the manufacturer.

Maintenance outline

Plan around bushings, thrust washers and the bearings that carry the outer magnet. Silicon carbide bushings extend life on abrasive services but are less tolerant of dry running, so choose according to the liquid. Check the relief valve setting at each major overhaul, and verify the canister for any sign of rubbing, a sign that bushings have worn through.

Reading the model number

The catalog explains that a model number starts with the size, then the series, then the coupling and drive designations. For the Viking Pump QS8124A, QS is the size, the first 8 means a sealless configuration, 1 means non-jacketed bracket, 2 identifies the basic design and 4 shows cast iron as the material of construction, with the letter A marking the series edition. Any further suffix describes the coupling and drive unit, so please quote the full string from the nameplate whenever a replacement or spare is needed.

Safety and environmental value

In a plant with large volumes of hazardous liquid, the shaft seal on a big pump is often the most likely release point. By hermetically enclosing the liquid, the Viking Pump QS8124A lowers the risk of vapour exposure for operators and of ground contamination from seal failure. It also reduces the need for seal flush supply, which can in turn reduce the quantity of waste. Those benefits must be weighed against the temperature limit of the magnets and the care needed to avoid running dry for long periods.

Related items you may also need: KRACHT KF 4/180 G20B P00 7VP2 Transfer Gear Pump | Debem Cubic 15 Compact Air-Operated Diaphragm Pump | KRACHT KF 0 Stainless Steel Process Gear Pump | All Viking Pump products.

Points to confirm for the Viking Pump QS8124A

  • If the Viking Pump QS8124A is a like-for-like replacement, read the full code from the installed nameplate and compare it with this page.
  • For each Viking Pump QS8124A request we confirm the exact code and lead time in writing.
  • Dimensions, ratings and connection data for the Viking Pump QS8124A are in the datasheet attached to this page.

Documents and quotation

The Viking catalog section covering the 8124A series is attached to this product. To receive a quotation for Viking Pump QS8124A, tell us the quantity, the liquid and its temperature, the drive arrangement and where the pump will be delivered in Oman or the GCC.

Other Models in the Viking 8124a Range

Seven Star LLC supplies models from the Viking 8124a range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Viking Pump K8124A Sealless Mag Drive Internal Gear PumpPositive Displacement PumpsView details
Viking Pump L8124A 135 GPM Cast Iron Mag Drive Gear PumpPositive Displacement PumpsView details
Viking Pump LS8124A 200 GPM Mag Drive Internal Gear PumpPositive Displacement PumpsView details
Viking Pump Q8124A 300 GPM Mag Drive Internal Gear PumpPositive Displacement PumpsView details
Viking Pump QS8124A 500 GPM Mag Drive Internal Gear PumpPositive Displacement PumpsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Viking Pump QS8124A 500 GPM Mag Drive Internal Gear Pump Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Viking Pump is the American maker of positive displacement pumps best known for the internal gear pump, often described as the "gear-within-a-gear" design. The principle goes back to Jens Nielsen, a Danish-born quarry owner in Cedar Falls, Iowa, who needed a better way to drain water from his quarry and patented his internal gear pump in 1904. In 1911 Nielsen and three local partners formed the Viking Pump Company in Cedar Falls, which is still the company's home. Viking has been part of IDEX Corporation since 1989.

Viking Pump company profile

Founded 1911, Cedar Falls, Iowa, USA, by Jens Nielsen with P.C. Petersen, W.L. Hearst and George Wyth
Headquarters Cedar Falls, Iowa, USA
Ownership A unit of IDEX Corporation since 1989
Core technology Internal gear pumps (rotor, idler gear and crescent), plus external gear, vane, lobe and circumferential piston pumps
Typical liquids Viscous and difficult liquids: fuel and lube oils, asphalt and bitumen, resins, polymers, chemicals, ammonia, molasses, inks and adhesives
Standards API 676 versions for refinery and petrochemical service; jacketed and heated versions for liquids that must be kept hot

Milestones

  • 1904: Jens Nielsen patents his internal gear pump design.
  • 1911: Viking Pump Company is founded in Cedar Falls, Iowa.
  • 1989: Viking becomes part of IDEX Corporation.
  • 2011: Viking marks 100 years in Cedar Falls.
  • Today: Internal and external gear pumps, mag drive pumps and API 676 pumps sold through distributors worldwide.

How a Viking internal gear pump works

An internal gear pump has two moving parts: an outer rotor gear and a smaller idler gear that turns inside it, offset on a pin. A crescent-shaped partition on the head fills the space between them. As the gears come out of mesh on the suction side, liquid fills the opening tooth spaces, is carried around both sides of the crescent and is pushed out as the teeth mesh again on the discharge side. Flow is smooth and almost proportional to speed, so the same pump can handle thin solvents or very thick liquids. The pump is reversible, and an internal relief valve is often fitted to protect it if the discharge is blocked. For thick liquids, choose a larger pump at a lower speed; for hot products such as asphalt, choose a jacketed or heated version.

Where Viking pumps are used in Oman and the GCC

In the region, Viking pumps move fuel oil, lube oil and base oils in refineries and terminals, bitumen and asphalt in road-building and storage plants, resins and chemicals in petrochemical plants, and ammonia in refrigeration systems. External gear pumps such as the GB series are used for chemical injection into pipelines, and mag drive pumps are chosen where a seal leak is not acceptable.

Viking Pump models we list

Family Examples
General-purpose internal gear pumps KK124C, H1124C O-Pro, QS124C, M124A, N324A, RS4324A
Jacketed and heated pumps KK224C, Q224C, M224A, KK124E asphalt
Steel and stainless steel pumps L123C, QS4123C, RS4323A, KK127C, Q4127C
API 676 pumps LS4223AX, Q4223AX, N4323AX, R4323AX, KK4223AA
Motor speed, external gear and mag drive pumps HL495, AK4195, GB-41013, GB-41430, SG-0741, AK893 mag drive
Special-duty pumps KK4924A ammonia, KK4624C abrasive, LVP41027 vane

Ordering Viking pumps: what we need

Send the full model number and serial number from the nameplate. The letters at the start of the model (for example G, H, KK, LS, Q or RS) give the pump size, and the digits give the construction, seal and material. For a new pump, tell us the liquid, its viscosity and temperature, the flow rate, the discharge pressure, the port size and whether you need a jacket, a relief valve, a motor and baseplate, or API 676 construction. For spares, send the model and serial number and say whether you need the rotor, idler, idler pin, bushing or seal kit.

Facts checked against Viking Pump and IDEX company history and published Viking product catalogues, November 2026.

FAQ

Questions about the Viking Pump QS8124A 500 GPM Mag Drive Internal Gear

Answers from our engineering team on installation, compatibility and integration.

01What is the flow rate of the Viking Pump QS8124A?
The catalog gives 500 GPM (114 m3/h) at 520 rpm on medium viscosity liquid, the highest rating in the 8124A series.
02What ports does the QS8124A have?
It has 6 inch (150 mm) ports, standard in a 180 degree arrangement with an option of 90 degree ports, unlike the other 8124A sizes.
03How heavy is the QS8124A?
The shipping weight with relief valve is about 775 lb (352 kg), so lifting equipment is needed for installation.
04Is the QS8124A a sealless pump?
Yes, it uses a magnetic drive through a 316L stainless canister, so no dynamic shaft seal is fitted.
05How is the QS8124A different from the Q8124A?
Both share a 520 rpm rating and a 300 PSIG hydrostatic limit, but the QS has 6 inch ports and 500 GPM compared with 4 inch ports and 300 GPM for the Q.