Brand:

Viking Pump G124A Cast Iron Internal Gear Pump 8 GPM

Description

Overview

For metering small flows of oil, resin or syrup with a pump that tolerates dirt, heat and viscosity better than most alternatives, the Viking Pump G124A is the compact answer in the Viking cast iron line. It is the G size of the older 124A series, a one-inch internal gear pump with a nominal rating of 8 gallons per minute at 1750 rpm, weighing only about 9.3 kg. The A in the code refers to the universal bracket for stuffing box seals, so the pump takes packing or conventional single seals in the stuffing box rather than the cartridge options of the later C bracket. Seven Star LLC is an independent supplier serving Oman and the GCC.

The 124A series and the letter A

The model number key in the catalog reads from left to right. G is the size, 124 is the basic series, and the final letter is the bracket type: A is the universal bracket for stuffing box seals, B is a behind-the-rotor arrangement and C is the U-Plus bracket that serves both. Digits in front of the series number show the shaft seal, where 4 means a mechanical seal and a missing digit means packing. This is why the G124A has packing, whereas the G4124A has a mechanical seal and the G4124B has a mechanical seal behind the rotor. When ordering spares, use the full code to get the right bracket and seal parts.

Specification of Viking Pump G124A

Parameter Catalog value
Series 124A, cast iron, non-jacketed, universal bracket
Nominal rating 8 GPM (1.8 m3/h) at 1750 rpm
Standard port size 1 inch NPT
Maximum discharge pressure 200 PSIG (14 bar)
Maximum hydrostatic pressure 400 PSIG (28 bar)
Maximum recommended temperature 450 degrees F (230 degrees C)
Operating viscosity range 28 to 2,000,000 SSU (0.1 to 440,000 cSt)
Casing, head, bracket Cast iron ASTM A48 Class 35B
Shipping weight with valve 20.55 lb (9.3 kg)

How Viking Pump G124A differs from other 124A and 124C pumps

Its direct relatives are the G4124A, rated 8 GPM with a mechanical seal and 350 degrees F, and the G4124B with a behind-the-rotor seal, which share the same ports and speed. Weighing 20.55 lb, the G124A is lighter than the G4124A at 21.61 lb. Above it, the H124C has 1 1/2 inch ports and 15 GPM, so the G is the only one-inch pump in the table and the smallest of the Universal Product Line. Pick it where flow demand is under 2 m3/h and a compact package matters.

Typical uses in Oman and the GCC

Very small gear pumps feed burners, lubricate machinery, dose additives, fill drums and circulate heat transfer oil in pilot plants. Workshops and fabricators in the region use them on test benches for engine and gearbox oil, and maintenance teams fit them in portable transfer sets for lubricants and diesel. Since the pump is self-priming and can run in both directions, it can draw from a drum and also return liquid.

Installation guidelines

Bolt the pump to a flat base and drive it through a flexible coupling or belt. Use pipe at least as large as the port, with a strainer and a pressure gauge, and add a relief valve in the discharge because there is no other protection against a closed line. Take care that the stuffing box is accessible, so packing can be adjusted without removing the pump. Turn the shaft by hand after assembly to confirm free rotation.

Packing and seal care

Packing should weep slightly to stay cool, so tighten the gland gradually until leakage is only a few drops per minute, and replace the rings when adjustment no longer controls leakage. If dry running is likely, consider a mechanical seal version instead. For liquids that crystallise on drying, a flush connection prevents damage. Remember that the stuffing box seal is the part most often serviced on a small pump.

Maintenance and spares

Check for noise, check the coupling for wear and keep the strainer clean. Replace bushings when the shaft shows play, and replace the idler pin if it is scored. Spare kits for small pumps are inexpensive, so hold one kit for every pump on critical duty. Record the model code and serial number so that parts can be ordered correctly.

Ordering the Viking Pump G124A

When requesting the Viking Pump G124A, state the liquid, viscosity, temperature, flow and speed, the drive type and whether you need a motor or base plate. If a mechanical seal is preferred, ask for the G4124A or G4124B instead.

Running a small gear pump efficiently

A pump this small is often installed without much calculation, and that is where problems start. Work out the pressure drop in the suction line for the real viscosity, because a long thin hose that works for water may starve the pump of thick oil. Keep the suction lift small and the line free of air pockets. Use the pump speed to adjust flow rather than throttling the discharge, as throttling sends liquid through the relief valve and heats it. For metering duty, a gear drive or a variable frequency drive gives a repeatable flow, and a calibrated container with a stopwatch gives a quick field check. If the liquid is abrasive, choose harder bushing and shaft materials from the options list, accept a shorter service interval and fit a finer strainer. Keep a simple log of the date, hours, flow and motor current in the pump folder, which will show wear long before a failure interrupts production.

Finally, label the pump with the direction of rotation and the port function, since a reversed motor connection turns suction into discharge and can burst a hose or damage a gauge.

Related items you may also need: Alfa Laval Cryogenic Reciprocating Pumps (Cryomec) | Allweiler ALLIFT Submersible Elevator Screw Pump Series | KRACHT KP 1/4 G10A K0A 4NL1 High-Pressure Gear Pump | All Viking Pump products.

Documents and quotation

The catalog section for the cast iron 124 series is attached to this page, with operating ranges, materials and dimensions. Please send your RFQ with Viking Pump G124A, the quantity and your delivery location in Oman or the GCC.

Other Models in the 124c Range

Seven Star LLC supplies models from the 124c range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Viking Pump K124C Cast Iron Internal Gear Pump 80 GPMPositive Displacement PumpsView details
Viking Pump LL124C Cast Iron Internal Gear Pump 140 GPMPositive Displacement PumpsView details
Viking Pump Q124C Cast Iron Internal Gear Pump 300 GPMPositive Displacement PumpsView details
Viking Pump G124A Cast Iron Internal Gear Pump 8 GPMPositive Displacement PumpsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Viking Pump G124A Cast Iron Internal Gear Pump 8 GPM Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Viking Pump is the American maker of positive displacement pumps best known for the internal gear pump, often described as the "gear-within-a-gear" design. The principle goes back to Jens Nielsen, a Danish-born quarry owner in Cedar Falls, Iowa, who needed a better way to drain water from his quarry and patented his internal gear pump in 1904. In 1911 Nielsen and three local partners formed the Viking Pump Company in Cedar Falls, which is still the company's home. Viking has been part of IDEX Corporation since 1989.

Viking Pump company profile

Founded 1911, Cedar Falls, Iowa, USA, by Jens Nielsen with P.C. Petersen, W.L. Hearst and George Wyth
Headquarters Cedar Falls, Iowa, USA
Ownership A unit of IDEX Corporation since 1989
Core technology Internal gear pumps (rotor, idler gear and crescent), plus external gear, vane, lobe and circumferential piston pumps
Typical liquids Viscous and difficult liquids: fuel and lube oils, asphalt and bitumen, resins, polymers, chemicals, ammonia, molasses, inks and adhesives
Standards API 676 versions for refinery and petrochemical service; jacketed and heated versions for liquids that must be kept hot

Milestones

  • 1904: Jens Nielsen patents his internal gear pump design.
  • 1911: Viking Pump Company is founded in Cedar Falls, Iowa.
  • 1989: Viking becomes part of IDEX Corporation.
  • 2011: Viking marks 100 years in Cedar Falls.
  • Today: Internal and external gear pumps, mag drive pumps and API 676 pumps sold through distributors worldwide.

How a Viking internal gear pump works

An internal gear pump has two moving parts: an outer rotor gear and a smaller idler gear that turns inside it, offset on a pin. A crescent-shaped partition on the head fills the space between them. As the gears come out of mesh on the suction side, liquid fills the opening tooth spaces, is carried around both sides of the crescent and is pushed out as the teeth mesh again on the discharge side. Flow is smooth and almost proportional to speed, so the same pump can handle thin solvents or very thick liquids. The pump is reversible, and an internal relief valve is often fitted to protect it if the discharge is blocked. For thick liquids, choose a larger pump at a lower speed; for hot products such as asphalt, choose a jacketed or heated version.

Where Viking pumps are used in Oman and the GCC

In the region, Viking pumps move fuel oil, lube oil and base oils in refineries and terminals, bitumen and asphalt in road-building and storage plants, resins and chemicals in petrochemical plants, and ammonia in refrigeration systems. External gear pumps such as the GB series are used for chemical injection into pipelines, and mag drive pumps are chosen where a seal leak is not acceptable.

Viking Pump models we list

Family Examples
General-purpose internal gear pumps KK124C, H1124C O-Pro, QS124C, M124A, N324A, RS4324A
Jacketed and heated pumps KK224C, Q224C, M224A, KK124E asphalt
Steel and stainless steel pumps L123C, QS4123C, RS4323A, KK127C, Q4127C
API 676 pumps LS4223AX, Q4223AX, N4323AX, R4323AX, KK4223AA
Motor speed, external gear and mag drive pumps HL495, AK4195, GB-41013, GB-41430, SG-0741, AK893 mag drive
Special-duty pumps KK4924A ammonia, KK4624C abrasive, LVP41027 vane

Ordering Viking pumps: what we need

Send the full model number and serial number from the nameplate. The letters at the start of the model (for example G, H, KK, LS, Q or RS) give the pump size, and the digits give the construction, seal and material. For a new pump, tell us the liquid, its viscosity and temperature, the flow rate, the discharge pressure, the port size and whether you need a jacket, a relief valve, a motor and baseplate, or API 676 construction. For spares, send the model and serial number and say whether you need the rotor, idler, idler pin, bushing or seal kit.

Facts checked against Viking Pump and IDEX company history and published Viking product catalogues, November 2026.

FAQ

Questions about the Viking Pump G124A Cast Iron Internal Gear Pump 8 GPM

Answers from our engineering team on installation, compatibility and integration.

01What flow does the Viking Pump G124A deliver?
The catalog lists a nominal rating of 8 GPM, 1.8 m3/h, at 1750 rpm for liquids of 100 SSU and below.
02What does the A in G124A stand for?
It denotes the universal bracket for stuffing box seals; with no digit in front of 124 the shaft seal is packing.
03What port size does the G124A have?
It has standard 1 inch NPT ports, the smallest size in the cast iron Universal Product Line.
04How heavy is the G124A?
The approximate shipping weight with valve is 20.55 lb, about 9.3 kg.
05How does the G124A differ from the G4124A?
The G124A uses packing and is rated to 450 degrees F, while the G4124A uses a mechanical seal and is rated to 350 degrees F.