Brand:

Viking Pump Q124C Cast Iron Internal Gear Pump 300 GPM

Description

Overview

High-volume transfer of viscous liquids is the territory of the Viking Pump Q124C, a heavy internal gear pump from the 124C family with 4 inch NPT ports and a nominal capacity of 300 gallons per minute. Its rated shaft speed is 520 rpm, its maximum discharge pressure is 200 PSIG and its cast iron casing is designed for non-corrosive liquids from thin oils to products with a viscosity of two million SSU. It weighs more than 450 lb, so it is a base-mounted machine for fixed installations. Seven Star LLC is an independent supplier serving Oman and the GCC.

Capacity thinking for the Viking Pump Q124C

At 300 GPM, the pump moves about 68 cubic metres per hour of liquid at 100 SSU and below. That is substantial for a gear pump, and it explains why the casing, bracket and bearings are large. The slow shaft speed of 520 rpm is a sign of conservative design: lower speed means lower sliding velocity in the bushings and a longer life with abrasive or poorly lubricating liquids. If the liquid is much thicker than 100 SSU, the catalog recommends derating the speed, because the tooth spaces fill more slowly. For such cases a variable speed drive or a gearbox with a tailored ratio is the usual route.

Data for Viking Pump Q124C

Item Catalog value
Nominal rating 300 GPM (68 m3/h) at 520 rpm
Port size 4 inch NPT
Maximum discharge pressure 200 PSIG (14 bar)
Maximum hydrostatic pressure 250 PSIG (17 bar)
Maximum recommended temperature 450 degrees F (232 degrees C)
Materials Cast iron ASTM A48 Class 35B for casing, head, bracket
Shaft options High strength steel, ASTM A434 grade 4140 class BC
Shipping weight with valve 450.6 lb (204.5 kg)
Viscosity range 28 to 2,000,000 SSU (0.1 to 440,000 cSt)

How Viking Pump Q124C differs from other 124C models

The Q1124C has the same 4 inch ports but is rated 275 GPM at 470 rpm because its O-Pro seal limits the speed and temperature to 350 degrees F, while the Q4124C keeps 300 GPM with mechanical seals. The QS124C goes to 6 inch ports and 500 GPM, a different frame size entirely. Below it, the LS124C, at 3 inch ports and 200 GPM, weighs less than half as much. The Q124C is therefore the largest 4 inch pump in the line, and the choice when more than 275 GPM must pass through a 4 inch pipe.

Use in Oman and the GCC

A pump of this capacity serves marine fuel transfer, crude and residual oil handling at storage terminals, bulk lubricant blending, asphalt loading and large resin plants. Terminals around Sohar, Duqm and Salalah load and discharge tankers with gear pumps of this size, thanks to the reversible, self-priming nature and the ability to handle viscosity swings caused by temperature. The cast iron body is practical where the liquid is oil-based and non-corrosive.

Foundations and piping

The pump must sit on a rigid base, and the driver must be aligned precisely, because a heavy shaft with a misaligned coupling will damage bearings. The 4 inch pipes need their own supports, expansion joints where heated, and a large relief valve sized for the full pump flow, since a closed discharge would otherwise overload the drive. Use a suction strainer with ample area, install pressure gauges with isolators, and make sure suction pipework is not smaller than the port.

Seals and clearances

The catalog lists many sealing options for the U-Plus bracket. For large pumps, cartridge seals are practical because they can be changed without removing the head or rotor. Special clearances are available for hot or very thick liquids, so state the operating temperature at the time of the enquiry; the right clearance prevents seizing when the casing expands.

Maintenance

Schedule inspection for bushings and end clearance at the interval suggested by the manual and by your duty, replace seals when leakage rises and keep the bearing housing lubricated. Record flow versus speed on a regular basis: falling flow at constant speed shows internal wear. For critical duty, hold a spare rotor and shaft assembly and a complete seal kit on site.

Ordering Viking Pump Q124C

Provide the liquid, viscosity curve, flow, pressure, temperature, driver and preferred seal when requesting the Viking Pump Q124C. If you need a base plate, coupling or a gearbox, say so, because they influence the delivery schedule.

Starting, stopping and protecting the Viking Pump Q124C

Large positive displacement pumps need disciplined operation. Before the first start, check that all valves in the suction and discharge lines are open, that the relief valve is set correctly and that the shaft turns by hand. Start the pump unloaded if possible, watch the pressure gauges rise smoothly and listen for knocking, which can indicate air or a misaligned coupling. When stopping, close the discharge valve only after switching off the driver or let the relief valve handle the residual pressure. If the liquid solidifies on cooling, flush the pump with a suitable flushing oil, or keep the line heated so that the next start does not shear the shaft against solid product.

Fit a motor protection relay with a current limit, and consider a vibration and temperature monitor on the bearing housing. Such monitoring costs little, and a pump of 300 GPM is a large asset whose unplanned shutdown can delay a whole loading operation at a terminal. Train the operators on the start-up checklist and post it beside the pump so that every shift follows the same routine.

Related items you may also need: NETZSCH TORNADO T2 Rotary Lobe Pump | KRACHT RA 42-Z50/38-Z50/55 Coupling for KF Gear Pump | VERDERAIR VA50 Metallic Air-Operated Double Diaphragm Pump | All Viking Pump products.

Documents and quotation

The catalog section for the 124C series is attached to this page, with operating ranges, materials and dimensions. Please send your RFQ with Viking Pump Q124C, the quantity and your delivery location in Oman or the GCC.

Other Models in the 124c Range

Seven Star LLC supplies models from the 124c range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Viking Pump K124C Cast Iron Internal Gear Pump 80 GPMPositive Displacement PumpsView details
Viking Pump LL124C Cast Iron Internal Gear Pump 140 GPMPositive Displacement PumpsView details
Viking Pump Q124C Cast Iron Internal Gear Pump 300 GPMPositive Displacement PumpsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Viking Pump Q124C Cast Iron Internal Gear Pump 300 GPM Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Viking Pump is the American maker of positive displacement pumps best known for the internal gear pump, often described as the "gear-within-a-gear" design. The principle goes back to Jens Nielsen, a Danish-born quarry owner in Cedar Falls, Iowa, who needed a better way to drain water from his quarry and patented his internal gear pump in 1904. In 1911 Nielsen and three local partners formed the Viking Pump Company in Cedar Falls, which is still the company's home. Viking has been part of IDEX Corporation since 1989.

Viking Pump company profile

Founded 1911, Cedar Falls, Iowa, USA, by Jens Nielsen with P.C. Petersen, W.L. Hearst and George Wyth
Headquarters Cedar Falls, Iowa, USA
Ownership A unit of IDEX Corporation since 1989
Core technology Internal gear pumps (rotor, idler gear and crescent), plus external gear, vane, lobe and circumferential piston pumps
Typical liquids Viscous and difficult liquids: fuel and lube oils, asphalt and bitumen, resins, polymers, chemicals, ammonia, molasses, inks and adhesives
Standards API 676 versions for refinery and petrochemical service; jacketed and heated versions for liquids that must be kept hot

Milestones

  • 1904: Jens Nielsen patents his internal gear pump design.
  • 1911: Viking Pump Company is founded in Cedar Falls, Iowa.
  • 1989: Viking becomes part of IDEX Corporation.
  • 2011: Viking marks 100 years in Cedar Falls.
  • Today: Internal and external gear pumps, mag drive pumps and API 676 pumps sold through distributors worldwide.

How a Viking internal gear pump works

An internal gear pump has two moving parts: an outer rotor gear and a smaller idler gear that turns inside it, offset on a pin. A crescent-shaped partition on the head fills the space between them. As the gears come out of mesh on the suction side, liquid fills the opening tooth spaces, is carried around both sides of the crescent and is pushed out as the teeth mesh again on the discharge side. Flow is smooth and almost proportional to speed, so the same pump can handle thin solvents or very thick liquids. The pump is reversible, and an internal relief valve is often fitted to protect it if the discharge is blocked. For thick liquids, choose a larger pump at a lower speed; for hot products such as asphalt, choose a jacketed or heated version.

Where Viking pumps are used in Oman and the GCC

In the region, Viking pumps move fuel oil, lube oil and base oils in refineries and terminals, bitumen and asphalt in road-building and storage plants, resins and chemicals in petrochemical plants, and ammonia in refrigeration systems. External gear pumps such as the GB series are used for chemical injection into pipelines, and mag drive pumps are chosen where a seal leak is not acceptable.

Viking Pump models we list

Family Examples
General-purpose internal gear pumps KK124C, H1124C O-Pro, QS124C, M124A, N324A, RS4324A
Jacketed and heated pumps KK224C, Q224C, M224A, KK124E asphalt
Steel and stainless steel pumps L123C, QS4123C, RS4323A, KK127C, Q4127C
API 676 pumps LS4223AX, Q4223AX, N4323AX, R4323AX, KK4223AA
Motor speed, external gear and mag drive pumps HL495, AK4195, GB-41013, GB-41430, SG-0741, AK893 mag drive
Special-duty pumps KK4924A ammonia, KK4624C abrasive, LVP41027 vane

Ordering Viking pumps: what we need

Send the full model number and serial number from the nameplate. The letters at the start of the model (for example G, H, KK, LS, Q or RS) give the pump size, and the digits give the construction, seal and material. For a new pump, tell us the liquid, its viscosity and temperature, the flow rate, the discharge pressure, the port size and whether you need a jacket, a relief valve, a motor and baseplate, or API 676 construction. For spares, send the model and serial number and say whether you need the rotor, idler, idler pin, bushing or seal kit.

Facts checked against Viking Pump and IDEX company history and published Viking product catalogues, November 2026.

FAQ

Questions about the Viking Pump Q124C Cast Iron Internal Gear Pump 300

Answers from our engineering team on installation, compatibility and integration.

01What is the nominal capacity of the Viking Pump Q124C?
The catalog rates it at 300 GPM, about 68 m3/h, at 520 rpm for liquids of 100 SSU and below.
02What port size does the Q124C have?
It has standard 4 inch NPT ports, which sit above the 3 inch ports of the LL and LS models in the catalog.
03How heavy is the Q124C?
The approximate shipping weight with valve is 450.6 lb, about 204.5 kg.
04What pressure limits apply to the Q124C?
The maximum discharge pressure is 200 PSIG (14 bar) and the maximum hydrostatic pressure is 250 PSIG (17 bar).
05How does the Q124C differ from the Q1124C?
The Q1124C uses the O-Pro seal, which limits it to 275 GPM at 470 rpm and 350 degrees F, while the Q124C is rated 300 GPM at 520 rpm and 450 degrees F.