Brand: Viking Pump
Viking Pump LL124C Cast Iron Internal Gear Pump 140 GPM
Description
Overview
When a transfer line needs more than 100 gallons per minute of a thick liquid and a pump that can stay on duty for years, the Viking Pump LL124C comes into consideration. It is a cast iron internal gear pump from the Universal Product Line, with 3 inch NPT ports, a nominal rating of 140 GPM, a low shaft speed of 520 rpm and a maximum discharge pressure of 200 PSIG. At that size the casing is large enough for generous flow passages, so the pump can pass thick fluids with relatively little suction loss. Seven Star LLC is an independent supplier serving Oman and the GCC.
What sets the LL size apart
The LL belongs to the second page of the size table in the catalog, together with LS, Q, QS, M, N, R and RS, which are the larger bodies. Moving from the 2 inch L model, the casing grows to 3 inch ports, but the rated speed drops from 640 to 520 rpm so that tooth velocity stays within limits. Hydrostatic pressure is rated 300 PSIG (21 bar), lower than the 400 PSIG (28 bar) of the smaller sizes, a reminder that casings of larger pumps are designed with different margins. Always check the system relief setting against these figures.
Specification of Viking Pump LL124C
| Characteristic | Catalog figure |
|---|---|
| Nominal pump rating | 140 GPM (32 m3/h) at 520 rpm |
| Port size | 3 inch NPT |
| Maximum discharge pressure | 200 PSIG (14 bar) |
| Maximum hydrostatic pressure | 300 PSIG (21 bar) |
| Maximum recommended temperature | 450 degrees F (232 degrees C) |
| Series temperature range | minus 60 to plus 450 degrees F |
| Casing material | Cast iron ASTM A48 Class 35B |
| Bracket | U-Plus bracket |
| Shipping weight with valve | 195.98 lb (89.0 kg) |
How Viking Pump LL124C differs from other 124C models
The LS124C, a sibling with the same 3 inch ports, is rated at 200 GPM and 640 rpm and weighs 224.9 lb, so it moves more liquid but demands a faster shaft. The LL1124C is limited to 350 degrees F because of its O-Pro seal, and the LL4124C uses mechanical seals at the same 140 GPM rating. Going up, the Q124C has 4 inch ports and 300 GPM. If a project needs the lower weight and speed of the LL, with 140 GPM, choose this model; if more capacity is needed without changing the pipe size, the LS is the alternative.
Duty in Oman and the GCC
This size is typical for tank-farm loading skids, heavy fuel oil and bunker transfer, lubricating oil bulk handling, vegetable oil terminals and chemical intermediate lines that are not corrosive to iron. Power stations in the Gulf use pumps of this kind for fuel and lube oil, while refineries and terminals use them for slop oil and heated products. Gear pumps are self-priming and reversible, so a single pump can unload tankers and refill storage in the opposite direction.
Piping and supports
A pump of 196 lb needs a solid base plate bolted to a concrete foundation, with the driver and gearbox aligned using shims and a dial indicator. Pipework should be supported independently so that no strain reaches the ports, and a suction strainer is important to protect the rotor and idler. Install isolating valves, pressure gauges on both sides, and a relief valve piped to the tank. For heated products, trace and insulate the pipes and consider the jacketed pump variants if the liquid must be kept hot inside the casing.
Seal and material options
The U-Plus bracket supports packing, component seals, cartridge seals and the O-Pro seal. The catalog lists options for bushings, rotor, idler, shaft and elastomers, so the pump can be configured for abrasive or high temperature use. Select seal materials in accordance with the liquid and decide on a flush plan if the liquid crystallises or carries solids.
Maintenance routine
Monitor vibration, temperature at the bearing housing and discharge pressure, and listen for changes in sound. Replace bushings before the idler touches the casing. When the pump is overhauled, record end clearances, because worn parts increase slip, particularly with thin hot liquids at pressure. Maintain a spare seal kit and a spare rotor and shaft assembly for continuous processes.
Specifying the Viking Pump LL124C
State the liquid, viscosity at pumping temperature, flow, discharge pressure, suction condition and the driver details when you request Viking Pump LL124C. The catalog also gives NPSH required curves which the project engineer should verify.
Heated liquids and thermal growth with the Viking Pump LL124C
Many LL-size installations handle liquids that are only pumpable when hot, such as fuel oil, wax or syrup. As the casing warms up, the rotor, idler and shaft expand at different rates, so internal clearances change. Operating the pump cold with a stiff liquid wastes power and wears the bushings, while a pump that is too hot can lose efficiency because slip rises. A good practice is to pre-heat the line, circulate the liquid through the relief valve return until the temperature is stable, and only then raise the discharge pressure. Insulate the casing where safe, use heat tracing on the pipework, and ask for wider clearances where the pumping temperature is far above 100 degrees C. Record the viscosity at the real temperature on the purchase file, because the pump selection depends on it far more than on the nominal rating.
Keep the operating manual, the catalog page and the as-built drawing in one folder. It makes later spare part orders much faster, since the model and the clearance code are known.
Related items you may also need: KRACHT KF80RF2-D15 Gear Pump | VERDERAIR PURE VA-P40 Chemical Diaphragm Pump | Danfoss 180B0036 PAH 25 High-Pressure Water Pump | All Viking Pump products.
Documents and quotation
The catalog section for the 124C series is attached to this page, with operating ranges, materials, specifications and dimensions. Please send your RFQ with Viking Pump LL124C, the quantity and your delivery location in Oman or the GCC.
Other Models in the 124c Range
Seven Star LLC supplies models from the 124c range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Viking Pump K124C Cast Iron Internal Gear Pump 80 GPM | Positive Displacement Pumps | View details |
| Viking Pump LL124C Cast Iron Internal Gear Pump 140 GPM | Positive Displacement Pumps | You are viewing this model |
Datasheets & Documents
- Datasheet Viking Pump LL124C Cast Iron Internal Gear Pump 140 GPM Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Viking Pump is the American maker of positive displacement pumps best known for the internal gear pump, often described as the "gear-within-a-gear" design. The principle goes back to Jens Nielsen, a Danish-born quarry owner in Cedar Falls, Iowa, who needed a better way to drain water from his quarry and patented his internal gear pump in 1904. In 1911 Nielsen and three local partners formed the Viking Pump Company in Cedar Falls, which is still the company's home. Viking has been part of IDEX Corporation since 1989.
Viking Pump company profile
| Founded | 1911, Cedar Falls, Iowa, USA, by Jens Nielsen with P.C. Petersen, W.L. Hearst and George Wyth |
|---|---|
| Headquarters | Cedar Falls, Iowa, USA |
| Ownership | A unit of IDEX Corporation since 1989 |
| Core technology | Internal gear pumps (rotor, idler gear and crescent), plus external gear, vane, lobe and circumferential piston pumps |
| Typical liquids | Viscous and difficult liquids: fuel and lube oils, asphalt and bitumen, resins, polymers, chemicals, ammonia, molasses, inks and adhesives |
| Standards | API 676 versions for refinery and petrochemical service; jacketed and heated versions for liquids that must be kept hot |
Milestones
- 1904: Jens Nielsen patents his internal gear pump design.
- 1911: Viking Pump Company is founded in Cedar Falls, Iowa.
- 1989: Viking becomes part of IDEX Corporation.
- 2011: Viking marks 100 years in Cedar Falls.
- Today: Internal and external gear pumps, mag drive pumps and API 676 pumps sold through distributors worldwide.
How a Viking internal gear pump works
An internal gear pump has two moving parts: an outer rotor gear and a smaller idler gear that turns inside it, offset on a pin. A crescent-shaped partition on the head fills the space between them. As the gears come out of mesh on the suction side, liquid fills the opening tooth spaces, is carried around both sides of the crescent and is pushed out as the teeth mesh again on the discharge side. Flow is smooth and almost proportional to speed, so the same pump can handle thin solvents or very thick liquids. The pump is reversible, and an internal relief valve is often fitted to protect it if the discharge is blocked. For thick liquids, choose a larger pump at a lower speed; for hot products such as asphalt, choose a jacketed or heated version.
Where Viking pumps are used in Oman and the GCC
In the region, Viking pumps move fuel oil, lube oil and base oils in refineries and terminals, bitumen and asphalt in road-building and storage plants, resins and chemicals in petrochemical plants, and ammonia in refrigeration systems. External gear pumps such as the GB series are used for chemical injection into pipelines, and mag drive pumps are chosen where a seal leak is not acceptable.
Viking Pump models we list
| Family | Examples |
|---|---|
| General-purpose internal gear pumps | KK124C, H1124C O-Pro, QS124C, M124A, N324A, RS4324A |
| Jacketed and heated pumps | KK224C, Q224C, M224A, KK124E asphalt |
| Steel and stainless steel pumps | L123C, QS4123C, RS4323A, KK127C, Q4127C |
| API 676 pumps | LS4223AX, Q4223AX, N4323AX, R4323AX, KK4223AA |
| Motor speed, external gear and mag drive pumps | HL495, AK4195, GB-41013, GB-41430, SG-0741, AK893 mag drive |
| Special-duty pumps | KK4924A ammonia, KK4624C abrasive, LVP41027 vane |
Ordering Viking pumps: what we need
Send the full model number and serial number from the nameplate. The letters at the start of the model (for example G, H, KK, LS, Q or RS) give the pump size, and the digits give the construction, seal and material. For a new pump, tell us the liquid, its viscosity and temperature, the flow rate, the discharge pressure, the port size and whether you need a jacket, a relief valve, a motor and baseplate, or API 676 construction. For spares, send the model and serial number and say whether you need the rotor, idler, idler pin, bushing or seal kit.
Facts checked against Viking Pump and IDEX company history and published Viking product catalogues, November 2026.
Browse Viking Pump products by category: Positive Displacement Pumps.
FAQ
Questions about the Viking Pump LL124C Cast Iron Internal Gear Pump 140
Answers from our engineering team on installation, compatibility and integration.
01What is the nominal flow of the Viking Pump LL124C?
The catalog gives 140 GPM, 32 m3/h, at 520 rpm for liquids of 100 SSU and below.
02What port size does the LL124C have?
The standard port size is 3 inch NPT, which is shared with the LS124C model.
03What pressure limits apply to the LL124C?
Maximum discharge pressure is 200 PSIG (14 bar) and maximum hydrostatic pressure is 300 PSIG (21 bar).
04How heavy is the LL124C?
The approximate shipping weight with valve is 195.98 lb, about 89.0 kg.
05How does the LL124C differ from the LS124C?
The LS124C is rated 200 GPM at 640 rpm and weighs about 102.1 kg, while the LL124C is rated 140 GPM at 520 rpm.


















Reviews