Brand:

Viking Pump LS126A Ductile Iron Gear Pump 200 GPM 3 in

Description

Overview

Viking Pump LS126A is a ductile iron internal gear pump with 3 inch ports and a nominal 200 GPM (45 m3/h) at 640 rpm. In the 126A Series the casing is ductile iron to ASTM A536 Grade 60-40-18 instead of the grey cast iron of the 124A, which gives higher strength and impact resistance for the same pump envelope. The manufacturer calls the 126A the most versatile line of internal gear pumps because of the many design and material options. Seven Star LLC is an independent supplier serving Oman and the GCC.

This page helps maintenance and procurement teams identify the exact code Viking Pump LS126A and compare it with the packed and mechanical seal variants. The figures given are taken from the attached catalog section, so they can be checked line by line against the document before an order is placed.

Why choose ductile iron for the LS126A

Ductile iron contains graphite in nodular form, which lets the casting bend slightly before it breaks. That matters in plants where pipework loads, water hammer or accidental knocks are likely, and it is the reason many specifications for tank farm and terminal duty ask for ductile iron instead of grey iron. For hot liquids and for pumps on mobile skids, the stronger casing gives an extra safety margin, and for heavy duty the casing pressure rating of 400 PSIG hydrostatic on this size is a useful reference point when comparing options. Compared with a 124A or 124C pump of the same size, the Viking Pump LS126A has the same internal geometry and port size, so it fits the same baseplate and pipework footprint where the 124C LS size is in use. The rest of the pump follows the Universal Product Line design: a stuffing box that accepts packing, many component seals or a wide variety of cartridge seals, a rotatable bearing housing for end clearance adjustment and a cast iron relief valve.

Specification table

Parameter Value
Model Viking Pump LS126A, 126A Series, ductile iron, non-jacketed
Port size 3 inch
Nominal capacity 200 GPM (45 m3/h)
Rated speed 640 rpm
Maximum hydrostatic pressure 400 PSIG (28 bar)
Maximum discharge pressure 200 PSI (14 bar)
Maximum temperature, standard pump 450 F (232 C)
Shipping weight with valve 190 lb (86 kg)
Casing Ductile iron, ASTM A536 Grade 60-40-18
Idler Cast iron, ASTM A48 Class 35B
Idler pin Hardened steel, ASTM A108 Grade 1045
Standard packing Braided PTFE
Series capacity Up to 500 GPM (114 m3/h)

How LS126A differs from other 126A variants

The 126A Series is a size ladder. LS4126A has the same 200 GPM rating but uses a mechanical seal (carbon versus silicon Ni-Resist faces with FKM) and is limited to 350 F (175 C). KK126A moves 100 GPM (23 m3/h) through 2 inch ports at 780 rpm and weighs 110 lb (50 kg). LL126A moves 140 GPM at 520 rpm and weighs 185 lb (84 kg). Q126A moves 300 GPM through 4 inch ports and weighs 440 lb (200 kg), and QS126A moves 500 GPM through 6 inch ports and weighs 540 lb (245 kg); the last two have 250 PSIG hydrostatic ratings.

Applications for Viking Pump LS126A

Typical liquids include fuel oil, lubricants, resins, polymer solutions and heavy chemicals that do not attack iron, and the 3 inch port size matches common pipe sizes in transfer stations, which simplifies retrofits. Many Gulf buyers specify ductile iron when the pump will stand outdoors in heat and dust, since the casing resists thermal stress and handling knocks. Transfer of fuel oil, lube oil, asphalt-type products and polymers at moderate pressures, mobile skid-mounted pumping sets, tanker loading and general plant utility. The pump suits Gulf plants that need extra casing strength for outdoor installation.

Selection guidance for Viking Pump LS126A

The key decision is whether ductile iron is required or whether grey cast iron is enough. If your pipework is rigid, the pump sits outdoors or the duty includes thermal shocks, the extra toughness of ductile iron is worth the choice. Otherwise the 124C cast iron LS124C offers the same capacity at 640 rpm. The second decision is the seal: packing on the Viking Pump LS126A is forgiving with abrasive or crystallising liquids and tolerates up to 450 F, whereas the LS4126A mechanical seal reduces leakage but is limited to 350 F. A third decision is porting and flange standard, since the catalog lists a range of casing options by size.

  • Pick Viking Pump LS126A for packed duty and LS4126A for mechanical seal duty.
  • Check suction pressure under 50 PSIG.
  • Check liquid compatibility with ductile iron.
  • Use performance curves for the actual viscosity.
  • Decide on flange standard.

Installation and maintenance

Ductile iron pumps are installed in the same way as cast iron ones, but the extra casing strength allows a little more tolerance for piping loads; even so, support pipework independently. Mount on a rigid base with a spacer coupling to leave access to the stuffing box, adjust packing gradually, and keep the relief valve return open. Replace packing and bushings as needed, and reset end clearance with the rotatable housing. Inspect the idler pin for wear at every overhaul, keep an idler and bushing set in stock, and record weep rates so that packing replacement can be scheduled rather than reactive. The catalog describes tapered roller or double row bearings that control axial thrust, so grease them according to the manual. Before the first start, fill the casing with liquid, turn the shaft by hand and confirm that suction and discharge valves are open.

Related items you may also need: KRACHT KP 1/4 Q10A K0A 4NL1 High-Pressure Gear Pump | Debem Boxer 100 Air-Operated Double Diaphragm Pump | KRACHT KP 1/4 G10A K0A 4NL1 High-Pressure Gear Pump | All Viking Pump products.

Points to confirm for the Viking Pump LS126A

  • If the Viking Pump LS126A is a like-for-like replacement, read the full code from the installed nameplate and compare it with this page.
  • For each Viking Pump LS126A request we confirm the exact code and lead time in writing.

Documents and quotation

The attached catalog section covers the 126A and 4126A series. To request a quotation for Viking Pump LS126A, send the code Viking Pump LS126A and quantity through the RFQ form, with the liquid and temperature.

Datasheets & Documents
  • PDF Datasheet Viking Pump LS126A Ductile Iron Gear Pump 200 GPM 3 in Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Viking Pump is a global leader in positive displacement pumping solutions, building internal and external gear pumps at its base in Cedar Falls, Iowa, as an IDEX company. Its range includes the 1124C Series internal gear pumps with U-Plus bracket design and O-Pro seal technology, GB-425 Series external gear pumps for pipeline injection, RTPg tanker pumps, and hygienic rotary lobe and circumferential piston pumps. These pumps move viscous and problematic liquids across industrial, energy, hygienic and transport applications, from lubrication, fuel transfer and chemical processing to asphalt and food-grade duty. Seven Star LLC is an independent supplier serving Oman and the GCC, helping buyers specify Viking Pump models matched to their liquid, flow rate and sealing needs for dependable uptime.

FAQ

Questions about the Viking Pump LS126A Ductile Iron Gear Pump 200 GPM 3

Answers from our engineering team on installation, compatibility and integration.

01What is the capacity of the LS126A?
LS126A delivers a nominal 200 GPM (45 m3/h) at 640 rpm through 3 inch ports.
02What is the casing material of the LS126A?
The casing is ductile iron to ASTM A536 Grade 60-40-18, stronger than the grey iron used in the 124A series.
03What temperature can the LS126A handle?
The packed standard pump is rated to 450 F (232 C); the mechanical seal LS4126A is rated 350 F (175 C).
04What are the LS126A pressure ratings?
Maximum discharge pressure is 200 PSI (14 bar) and maximum hydrostatic pressure is 400 PSIG (28 bar).
05How heavy is the LS126A?
The shipping weight with valve is 190 lb (86 kg).