Brand: Panametrics
Panametrics Sentinel LNG Cryogenic Ultrasonic Flowmeter
Description
Sentinel LNG for cryogenic liquid measurement
Sentinel LNG is the Panametrics ultrasonic flowmeter built to measure liquefied natural gas and other cryogenic liquids directly by volume. Tank level gauging gives only an indirect volume, because the density of boiling LNG in a tank can vary with temperature, the tank expands under the weight of its contents, and on a ship pitch and wave movement disturb the level reading. Sentinel LNG removes these sources of uncertainty by measuring the flow itself in a fully welded, full-bore spool with no moving parts and a pressure drop equal to that of a straight pipe of the same length. The transducers are placed outside the cryogenic liquid, so the cold cannot degrade them over time.
What makes Sentinel LNG suited to cryogenic duty
- Bundle Waveguide Technology: all-metal buffer assemblies concentrate ultrasonic energy into the process and shield the transducers from cryogenic temperatures.
- Transducers can be removed from service safely without opening the pipeline, with no insertion mechanism or expensive valves.
- Robust Path Configuration developed by CFD simulation of highly turbulent LNG flow regimes, then proven on a calibration loop.
- Time-tested correction curves that translate a water calibration into cryogenic performance.
- Active Temperature Compensation by pulse-echo measurement of transducer dead time.
- Active flow compensation: live temperature input is used to calculate changes in flowcell dimensions and acoustic properties.
Sentinel LNG specifications
| Item | Sentinel LNG |
|---|---|
| Accuracy | Better than plus or minus 0.25% of measured volume from 2 to 30 ft/s (0.5 to 10 m/s) |
| Zero stability | Under 0.007 ft/s (0.002 m/s) |
| Process temperature | -200 to 120 C (-328 to 248 F) |
| Paths | Four-path Robust Path Configuration |
| Body materials | Stainless steel A182 304/304L or 316/316L |
| Size range | 4 in (100 mm) to 36 in (900 mm); 150 or 300 lb standard, others on request |
| Schedules | 10S, 40S, STD; PED Category III module H |
| Straight run | 20D upstream and 5D downstream, with inlet and outlet bore matching the meter |
| Electronics | Epoxy aluminum or A351 316 enclosure; 25 lb (11.5 kg); IP66; under 20 W |
| Supply | 100 to 240 VAC or 12 to 32 VDC |
| Outputs | Two frequency/pulse, two alarm relays, one 4-20 mA with HART; two 4-20 mA plus RTD or three 4-20 mA inputs |
| Hazardous area | Class I Div 1 B, C, D; ATEX II 2 G Ex de IIC; IECEx Ex de IIC |
| Weights, 4 in 150 lb | 150 lb (68 kg); 24 in 600 lb 3985 lb (1808 kg) |
How Sentinel LNG differs from other Sentinel meters
The Sentinel LNG shares a four-path body and electronics with the Sentinel LCT but is specified differently. Its accuracy is 0.25 percent against 0.15 percent for the LCT, over a narrower velocity window of 2 to 30 ft/s instead of 1 to 33 ft/s, and its zero stability is 0.007 ft/s instead of under 0.003 ft/s. The body is stainless steel only, with no carbon steel option, and the process range is fixed at -200 to 120 C. It uses BWT transducers with waveguide buffers, which the datasheet associates with the cryogenic design. The datasheet quotes remote electronics at up to 50 ft (15 m) in one passage and up to 300 ft in another, so the permitted cable length should be confirmed at order.
Where it is used
The datasheet lists LNG, cryogenic fluid allocation, custody transfer and marine cargo verification. For an Oman or GCC LNG terminal, that translates into cargo transfer lines between ship and shore tanks, truck loading arms and bunkering lines, plus allocation between trains at liquefaction sites. A meter that reads volume directly provides an independent check on tank gauging figures.
The commercial logic of a direct volume meter is worth spelling out. Every LNG cargo transfer is valued on volume and energy, so a fraction of a percent on a full ship cargo is a large quantity of product. Level gauges depend on tank strapping tables, temperature profiles and a density estimate; an inline meter reads the volume passing the point of transfer and can be cross-checked against gauging after the event. Because Sentinel LNG is available with an integrated flow computer, temperature and pressure signals can be combined with density input so that corrected volumes are available at the meter, and the HART and PanaLink interfaces pass them to the terminal supervisory system.
The CFD-based design work matters for LNG because the flow is typically highly turbulent and the cold liquid has low viscosity. Before calibration-loop testing the manufacturer simulated acoustic port effects and tested path layouts under such turbulent regimes, then proved the results in a loop. Operators should still plan the line routing sensibly: a 20 diameter straight upstream run free of nozzles, correct bore matching and downstream placement of the pressure, temperature and density connections are all part of the stated installation requirement and underpin the accuracy figure.
Installation notes
Place pressure, temperature and density connections downstream, keep the 20 diameter upstream run clear of nozzles that could disturb the profile, and match the pipe inner diameter to the meter. A live temperature input lets the electronics calculate dimensional changes of the flowcell. Customer wiring is kept in a separate compartment for safety, and local diagnostics can be read through magnetic contacts or via USB and PanaView, which also gives a configuration audit trail.
Servicing and supplier note
With welded construction and no moving parts, maintenance mainly involves diagnostics. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Documents and quotation
A manufacturer datasheet for Sentinel LNG is attached. Please send your RFQ giving the Sentinel LNG line size, flange class, body material, approvals needed and quantity.
Other Models in the Panametrics Sentinel Range
Seven Star LLC supplies models from the Panametrics Sentinel range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Panametrics Sentinel LCT Custody Transfer Ultrasonic Flowmeter | Ultrasonic Flowmeters | View details |
| Panametrics Sentinel LCT8 Eight-Path Ultrasonic Flowmeter | Ultrasonic Flowmeters | View details |
| Panametrics Sentinel LCT4 Compact Ultrasonic Liquid Flowmeter | Ultrasonic Flowmeters | View details |
| Panametrics Sentinel LNG Cryogenic Ultrasonic Flowmeter | Ultrasonic Flowmeters | You are viewing this model |
Datasheets & Documents
- Datasheet Panametrics Sentinel LNG Cryogenic Ultrasonic Flowmeter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Panametrics is an American maker of ultrasonic flowmeters and moisture, oxygen and gas analysers. It was founded in 1960 and was based in Waltham, Massachusetts, when GE bought it in 2002. It later became a Baker Hughes business, and since 1 January 2026 it has belonged to Crane Company. Its long-running site in Shannon, Ireland, opened in 1973.
Seven Star LLC lists Panametrics flowmeters and analyzers for buyers in Oman: DigitalFlow gas and flare meters, clamp-on and portable liquid meters, and trace moisture analyzers for natural gas and process gases. We are an independent supplier, so each inquiry is checked against the manufacturer's order string before a quotation goes out.
Panametrics company profile
| Founded | 1960, Massachusetts, USA |
|---|---|
| Main sites | Billerica, Massachusetts, and Shannon, Ireland (since 1973) |
| Ownership | Crane Company since 1 January 2026; previously GE (from 2002) and Baker Hughes |
| Key technology | Transit-time ultrasonic flow measurement and aluminium oxide moisture sensing |
| Product families | TransPort PT900 portable and DigitalFlow fixed ultrasonic flowmeters for liquid, gas and flare gas, aluminium oxide moisture probes and hygrometers, Aurora laser moisture analysers, XMO2 oxygen and XMTC thermal conductivity transmitters |
Milestones
- 1960: Panametrics is founded.
- 1973: The Shannon, Ireland, site is established.
- 2002: GE acquires Panametrics.
- 2026: Crane Company completes its purchase of Baker Hughes' Precision Sensors & Instrumentation, including Panametrics.
Panametrics product families on this page
The listed items follow the manufacturer's own grouping:
- Gas and flare flow: DigitalFlow GF868 flare gas meter, GM868 and XGM868i gas flow transmitters
- Liquid flow: XMT1000 transmitter, AT600 AquaTrans clamp-on meter, TransPort PT900 portable meter
- Moisture: moisture.IQ multichannel analyzer, HygroPro II aluminum oxide transmitter, Aurora TDLAS analyzer for natural gas
Older units may carry GE Panametrics or GE Sensing on the nameplate. They belong to the same product lines, and the model string is read the same way.
Where Panametrics flowmeters and moisture analyzers are used
Flare meters report flared volumes on production sites, refineries and LNG plants. Clamp-on and portable ultrasonic meters check water, hydrocarbon liquid and utility lines without cutting the pipe. Aluminum oxide and TDLAS moisture analyzers watch dehydration units, gas pipelines, hydrogen and industrial gas streams. The manufacturer also names chemical processing, energy and water and wastewater among its markets, which matches what GCC operators ask us for.
Panametrics products we list
Ordering Panametrics equipment: what we need
A Panametrics model is a long configuration string, and the transducers or probes are ordered separately. Please send the full model and serial number of the electronics, the transducer or moisture probe part number, pipe size, schedule and material, fluid, pressure and temperature, flow range, hazardous area approval and output or protocol. For a flare meter add the flare gas composition range and velocity range. For moisture, give the dew point range and whether sample system components are required.
Facts checked against GE's 2002 acquisition release, Crane Company's January 2026 completion release and Irish press, October 2026.
FAQ
Questions about the Panametrics Sentinel LNG Cryogenic Ultrasonic
Answers from our engineering team on installation, compatibility and integration.
01Why use Sentinel LNG instead of tank level gauging?
It measures volume directly, avoiding errors from changing LNG density, tank expansion and ship motion that affect level gauges.
02How are the transducers protected from cryogenic temperature?
Bundle Waveguide Technology buffers sit between the transducers and the liquid, concentrating the signal and shielding the transducers from the cold.
03What accuracy does Sentinel LNG state?
Better than plus or minus 0.25 percent of measured volume between 2 and 30 ft/s, with zero stability under 0.007 ft/s.
04What temperature range does Sentinel LNG cover?
Process temperatures from -200 to 120 C (-328 to 248 F).
05Is a special calibration needed for Sentinel LNG?
The meter uses time-tested correction curves that translate a water calibration into high-accuracy performance at cryogenic temperatures.