Brand: Panametrics
Panametrics Sentinel LCT Custody Transfer Ultrasonic Flowmeter
Description
Sentinel LCT: Panametrics custody transfer meter for liquid hydrocarbons
Sentinel LCT is the Panametrics four-path ultrasonic flowmeter designed for custody transfer of crude oil and refined liquid products. It was developed around one idea: combine reliability with the highest accuracy. The measuring spool is fully welded, with no gaskets and no threaded connections, and there is nothing in its geometry that can change and let the meter drift. The Sentinel LCT is a full-bore meter with no diameter reductions, so the pressure drop is simply that of an equal length of pipe, and no filters or strainers are needed. It targets and meets an accuracy of better than 0.15 percent of measured volume.
Sentinel LCT design features
- Robust Path Configuration, derived from computational fluid dynamics studies spanning laminar heavy crude to turbulent gasoline and LPG flows before any calibration loop test.
- True multi-viscosity behaviour: one calibration curve holds 0.15% accuracy from minimum to maximum viscosity, with no prover run when viscosity changes.
- Active Temperature Compensation: pulse-echo measurement of transducer dead time in real time as process temperature changes.
- Optional integrated flow computer in the SEN898 electronics, with API MPMS 11.1 corrections for temperature, pressure and density.
- One-time calibration; replacement of sensors or electronics has been tested and certified by NMi as keeping custody transfer accuracy.
- HART standard, local diagnostics through magnetic contacts or USB with PanaView software.
Sentinel LCT specification table
| Item | Sentinel LCT |
|---|---|
| Accuracy | Better than plus or minus 0.15% of measured volume from 1 to 33 ft/s (0.3 to 10 m/s) |
| Uncertainty | Better than plus or minus 0.027% per API MPMS 5.8 |
| Zero stability | Under 0.003 ft/s (0.0009 m/s) |
| Viscosity and Reynolds | 0 to 6600 cSt; Reynolds above 5,000 |
| Process temperature | -40 to 120 C (-40 to 248 F); -200 to 120 C for LNG; extended to 600 C by consultation |
| Sizes | 4 in (100 mm) to 36 in (900 mm); 150, 300 or 600 lb flanges |
| Body materials | Carbon steel A105/A350 LF2; stainless A182 304/304L or 316/316L |
| Schedules | 40S, STD, 80S, XS; PED Cat III, module H |
| Straight run | 20D upstream and 5D downstream, or 10D with a CPA plate conditioner |
| Electronics | Epoxy aluminum or A351 316 enclosure; 13 x 11 x 9 in; 25 lb (45 lb SS); IP66; 7 W |
| Power | 100 to 240 VAC or 12 to 32 VDC |
| I/O | Two frequency/pulse outputs, two alarm relays, one 4-20 mA with HART, 4-20 mA and RTD inputs |
| Hazardous areas | Class I Div 1 B, C, D; ATEX II 2 G Ex de IIC; IECEx Ex de IIC |
Approvals and certified flow ranges
The design meets OIML R117-1, MID MI-005 and API MPMS 5.8. Custody transfer approvals are listed as API MPMS 5.8 compliance in the United States, WELMEC Guide 8.8 under the MID in Europe and OIML R117-1 by NMi (certificate TC7595) elsewhere, with local type approvals on request; these approvals apply to the flowmeter only and not to the built-in flow computer. Typical certified rates at 1 ft/s and 33 ft/s run from 10 to 340 m3/h for the 4 in size up to 700 to 23,200 m3/h for 36 in, because the Sentinel LCT is full bore and its range is set by the pipe.
Where Sentinel LCT differs from LCT4 and LCT8
The base LCT is the four-path, high-accuracy model for custody transfer at 0.15 percent, covering 4 in to 36 in. Its siblings in the Sentinel range are named for their path counts and cover other duties, so check their separate pages. LCT also differs from the Sentinel LNG, which targets cryogenic liquid; the LCT carries a cryogenic option down to minus 200 C but is built primarily for crude and products.
Two further engineering points support the specification. The first is zero stability: the quoted figure of under 0.003 ft/s (0.0009 m/s) means the meter does not read a false flow when the line is stopped and full, which matters at low-flow transfers and when a leak-detection system compares inlet and outlet volumes. The second is the CFD-led validation: before any calibration loop test the meter geometry was explored in simulation, including the effect of the ultrasonic ports, and the loop tests on different viscosities then confirmed the result. Operators who buy a Sentinel LCT therefore receive a design whose path layout was chosen for both laminar heavy crude and turbulent light products, rather than a general-purpose multipath body adapted to custody service afterwards.
Applications in Oman and the Gulf
Crude export and import terminals, refinery product dispatch, pipeline allocation, leak detection and tank-farm transfers are the natural uses. Oman’s coastal terminals handle heavy fuel oil, crude, naphtha and gasoline in the same facility, and the NMi-witnessed results published in the datasheet cover heavy fuel oil at 580 cSt, naphtha at 1.2 cSt and kerosene at 2.55 cSt, so the multi-viscosity claim is backed by a wide range of liquids.
Installation and verification
Install with 20 diameters upstream and 5 downstream and match inlet and outlet piping to the meter bore within 1 percent. Pressure, temperature and density tapping points belong in the downstream piping. The electronics can be mounted on the spool or up to 300 ft (90 m) away. PanaView provides audit-trail checks on configuration; legal metrology rules in the country of use decide whether periodic re-verification is needed.
Servicing and supplier note
With no moving parts, service is limited to diagnostic reviews. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Documents and quotation
A manufacturer datasheet for Sentinel LCT is available. Please send an RFQ with the Sentinel LCT line size, flange class, body material, temperature range, approvals needed and quantity.
Datasheets & Documents
- Datasheet Panametrics Sentinel LCT Custody Transfer Ultrasonic Flowmeter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Panametrics is an American maker of ultrasonic flowmeters and moisture, oxygen and gas analysers. It was founded in 1960 and was based in Waltham, Massachusetts, when GE bought it in 2002. It later became a Baker Hughes business, and since 1 January 2026 it has belonged to Crane Company. Its long-running site in Shannon, Ireland, opened in 1973.
Seven Star LLC lists Panametrics flowmeters and analyzers for buyers in Oman: DigitalFlow gas and flare meters, clamp-on and portable liquid meters, and trace moisture analyzers for natural gas and process gases. We are an independent supplier, so each inquiry is checked against the manufacturer's order string before a quotation goes out.
Panametrics company profile
| Founded | 1960, Massachusetts, USA |
|---|---|
| Main sites | Billerica, Massachusetts, and Shannon, Ireland (since 1973) |
| Ownership | Crane Company since 1 January 2026; previously GE (from 2002) and Baker Hughes |
| Key technology | Transit-time ultrasonic flow measurement and aluminium oxide moisture sensing |
| Product families | TransPort PT900 portable and DigitalFlow fixed ultrasonic flowmeters for liquid, gas and flare gas, aluminium oxide moisture probes and hygrometers, Aurora laser moisture analysers, XMO2 oxygen and XMTC thermal conductivity transmitters |
Milestones
- 1960: Panametrics is founded.
- 1973: The Shannon, Ireland, site is established.
- 2002: GE acquires Panametrics.
- 2026: Crane Company completes its purchase of Baker Hughes' Precision Sensors & Instrumentation, including Panametrics.
Panametrics product families on this page
The listed items follow the manufacturer's own grouping:
- Gas and flare flow: DigitalFlow GF868 flare gas meter, GM868 and XGM868i gas flow transmitters
- Liquid flow: XMT1000 transmitter, AT600 AquaTrans clamp-on meter, TransPort PT900 portable meter
- Moisture: moisture.IQ multichannel analyzer, HygroPro II aluminum oxide transmitter, Aurora TDLAS analyzer for natural gas
Older units may carry GE Panametrics or GE Sensing on the nameplate. They belong to the same product lines, and the model string is read the same way.
Where Panametrics flowmeters and moisture analyzers are used
Flare meters report flared volumes on production sites, refineries and LNG plants. Clamp-on and portable ultrasonic meters check water, hydrocarbon liquid and utility lines without cutting the pipe. Aluminum oxide and TDLAS moisture analyzers watch dehydration units, gas pipelines, hydrogen and industrial gas streams. The manufacturer also names chemical processing, energy and water and wastewater among its markets, which matches what GCC operators ask us for.
Panametrics products we list
Ordering Panametrics equipment: what we need
A Panametrics model is a long configuration string, and the transducers or probes are ordered separately. Please send the full model and serial number of the electronics, the transducer or moisture probe part number, pipe size, schedule and material, fluid, pressure and temperature, flow range, hazardous area approval and output or protocol. For a flare meter add the flare gas composition range and velocity range. For moisture, give the dew point range and whether sample system components are required.
Facts checked against GE's 2002 acquisition release, Crane Company's January 2026 completion release and Irish press, October 2026.
FAQ
Questions about the Panametrics Sentinel LCT Custody Transfer
Answers from our engineering team on installation, compatibility and integration.
01What accuracy does the Sentinel LCT claim?
Better than plus or minus 0.15 percent of measured volume between 1 and 33 ft/s, with uncertainty under 0.027 percent per API MPMS 5.8.
02Does Sentinel LCT need recalibration when viscosity changes?
No. It is a true multi-viscosity meter that stays within 0.15 percent between minimum and maximum viscosity on a single calibration curve.
03Which approvals apply to the Sentinel LCT?
API MPMS 5.8, WELMEC Guide 8.8 under the MID and OIML R117-1 by NMi, valid for the flowmeter only and not for the built-in flow computer.
04What straight pipe run does Sentinel LCT need?
20 diameters upstream and 5 downstream, or 10 upstream with a CPA plate flow conditioner.
05What sizes is Sentinel LCT built in?
4 in (100 mm) to 36 in (900 mm) with ANSI 150, 300 or 600 flanges, other sizes on request.