Brand:

Panametrics PanaFlow LC Clamp-On Ultrasonic Liquid Flowmeter

Description

PanaFlow LC clamp-on liquid flowmeter overview

PanaFlow LC is the Panametrics permanent clamp-on ultrasonic flowmeter for process liquids. It descends from the XMT868 and XMT868i meters and pairs a remote XMT1000LC transmitter with externally mounted transducers, so the pipe is never opened. Because the transducers sit on the outside of the wall, no flanges, no welding and no process shutdown are required, and a solid couplant installation needs no routine maintenance because nothing is exposed to the fluid. The PanaFlow LC is aimed at refineries and chemical plants measuring hydrocarbon liquids, crude oil, lubricating oils, refined oils, solvents, chemicals, water and sea water, on lined or unlined pipes of most materials.

Key strengths of PanaFlow LC

  • Pipe sizes from 0.75 in to 300 in (20 mm to 7.5 m), wall thickness up to 4 in (100 mm).
  • Bidirectional range of 0.1 to 65.6 ft/s (0.03 to 20 m/s).
  • Automatic Tracking Window (ATW) follows changing sound speed when the liquid is unknown or varies.
  • One, two or three measurement paths from the XMT1000LC.
  • HART 7 and Foundation Fieldbus options; explosion-proof or flameproof certification; optional SIL configuration.
  • Velocity, volumetric, mass and totalized flow outputs.

PanaFlow LC performance data

Parameter Value
Accuracy 1% of reading for pipes of 2 in (50 mm) and larger above 1 ft/s; 2% below 2 in; 0.5% possible with field calibration
Repeatability 0.2% of reading typical
Measurement cycle 3 Hz typical, adjustable to 10 Hz
Straight run assumed About 10 diameters upstream, 5 downstream
Transmitter housing Powder-coated copper-free aluminum or stainless steel, NEMA 4X, IP66 and IP67; 10 lb (4.5 kg)
Dimensions 8.40 x 6.42 x 5.87 in (213.4 x 163.1 x 149.1 mm), 2 in pipe or wall mount
Ambient -40 to 149 F (-40 to 65 C); 60 C with Foundation Fieldbus
Power 100 to 240 VAC or 12 to 28 VDC; 15 W maximum, typically under 7 W
Outputs One 4-20 mA (600 ohm) plus one pulse or frequency output; optional extra analog, RTD, SIL outputs
Hazardous approval Class I Div 1 Groups B, C, D; Ex db IIC T6 Gb, ATEX and IECEx

Transducer choices for PanaFlow LC

The standard C-RS transducer runs at 0.5, 1 or 2 MHz, is IP66 with a junction box and handles process temperatures of -40 to 150 C (-40 to 302 F). A C-RS HT at 1 MHz extends to 230 C (446 F) and carries IP66/IP68. The C-ET transducer at 0.5 or 1 MHz covers the extreme range of -200 to 400 C (-328 to 752 F). Mounting uses a Strap Clamping Fixture with stainless steel yoke and strapping and an alignment bar; for small pipes with 2 MHz C-RS transducers the CFG fixture is used. Cable is RG62 coaxial in standard, armored, burial and submersible types up to 1000 ft (300 m).

Building a PanaFlow LC order code

A complete system has three order lines. First the transmitter, such as XMT1000LC, selecting paths (3-path MCX, 1-path FL or 2-path FL), AC or DC power, optional conformal coating, aluminum or SS316 enclosure, I/O set 00 to 09 or SL for a SIL output, certification (US/CAN, IECEx/ATEX, ECAS, Taiwan, China, India, Japan), and digital communication (none, HART or Foundation Fieldbus). The datasheet example is XMT1000LC-3-AC-1-AL-00-1-1-0-0. Second, the transducer and fixture system XMTXP with a frequency code such as R10 and the pipe outside diameter and unit, for example XMTXP-R10-EX-300-MM-1-0. Third, the cable FC line with HAZCOAX or armored cable and its length.

Where PanaFlow LC is used in Oman and the GCC

Typical roles include crude and product transfer lines, cooling-water and sea-water circuits, chemical dosing and solvent lines, and hazardous-area liquid lines where hot work or shutdown is hard to schedule. The retrofit advantage is strong at brownfield sites, since a clamp-on meter can be added on a live line. The XMT1000LC fits remote mounting on a pole or wall in hazardous areas.

Installation notes

Pick a section with a fully developed profile, enter the pipe and liquid data using the keypad or PanaView Plus, mount the transducers with the alignment bar and couplant, and set the spacing the meter reports. PanaView Plus logs up to 10,000 points with 26 parameters per point. Pipe wall thickness, lining and corrosion influence signal strength, so concrete, composite and highly corroded or lined pipes need factory consultation. In service the main task is checking signal strength and cable condition; the transmitter has no wetted parts to clean.

Why choose clamp-on for PanaFlow LC duties

Clamp-on metering removes several costs that usually appear in project budgets: no cutting into the pipe, no extra flanges or welding before the flowmeter is installed, and no need to wait for a turnaround. Since the transducers are not exposed to the process fluid, a solid couplant installation needs no maintenance, and there is no pressure drop or leak path introduced into the line. For a plant that already has a spool-piece meter, a PanaFlow LC can be mounted on the same line as an independent check, with the in-field calibration option allowing accuracy of 0.5 percent to be pursued.

The improvements over the older XMT868i are listed in the datasheet as faster signal processing, the latest HART and Foundation Fieldbus protocols, PanaView Plus software, one, two or three path measurement, improved rangeability and new diagnostics. A transit-time meter reads the difference between downstream and upstream travel times; when the liquid is still, both are equal, and the sign of the difference gives flow direction. That is why the same meter can be used on reversible transfer lines and on lines that occasionally see back-flow.

Related products and independence

For multi-technology options see the PanaFlow LZ, Z3 and XMT1000 pages. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Documents and quotation

The manufacturer datasheet for PanaFlow LC is provided. To get a quotation, send your RFQ listing the LC model, order string, pipe outside diameter and material, liquid and quantity.

Other Models in the Panametrics Panaflow Liquid Range

Seven Star LLC supplies models from the Panametrics Panaflow Liquid range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Panametrics PanaFlow Z3 PF10-Z3 Three-Path Liquid FlowmeterUltrasonic FlowmetersView details
Panametrics PanaFlow LC Clamp-On Ultrasonic Liquid FlowmeterUltrasonic FlowmetersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Panametrics PanaFlow LC Clamp-On Ultrasonic Liquid Flowmeter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Panametrics is an American maker of ultrasonic flowmeters and moisture, oxygen and gas analysers. It was founded in 1960 and was based in Waltham, Massachusetts, when GE bought it in 2002. It later became a Baker Hughes business, and since 1 January 2026 it has belonged to Crane Company. Its long-running site in Shannon, Ireland, opened in 1973.

Seven Star LLC lists Panametrics flowmeters and analyzers for buyers in Oman: DigitalFlow gas and flare meters, clamp-on and portable liquid meters, and trace moisture analyzers for natural gas and process gases. We are an independent supplier, so each inquiry is checked against the manufacturer's order string before a quotation goes out.

Panametrics company profile

Founded 1960, Massachusetts, USA
Main sites Billerica, Massachusetts, and Shannon, Ireland (since 1973)
Ownership Crane Company since 1 January 2026; previously GE (from 2002) and Baker Hughes
Key technology Transit-time ultrasonic flow measurement and aluminium oxide moisture sensing
Product families TransPort PT900 portable and DigitalFlow fixed ultrasonic flowmeters for liquid, gas and flare gas, aluminium oxide moisture probes and hygrometers, Aurora laser moisture analysers, XMO2 oxygen and XMTC thermal conductivity transmitters

Milestones

  • 1960: Panametrics is founded.
  • 1973: The Shannon, Ireland, site is established.
  • 2002: GE acquires Panametrics.
  • 2026: Crane Company completes its purchase of Baker Hughes' Precision Sensors & Instrumentation, including Panametrics.

Panametrics product families on this page

The listed items follow the manufacturer's own grouping:

  • Gas and flare flow: DigitalFlow GF868 flare gas meter, GM868 and XGM868i gas flow transmitters
  • Liquid flow: XMT1000 transmitter, AT600 AquaTrans clamp-on meter, TransPort PT900 portable meter
  • Moisture: moisture.IQ multichannel analyzer, HygroPro II aluminum oxide transmitter, Aurora TDLAS analyzer for natural gas

Older units may carry GE Panametrics or GE Sensing on the nameplate. They belong to the same product lines, and the model string is read the same way.

Where Panametrics flowmeters and moisture analyzers are used

Flare meters report flared volumes on production sites, refineries and LNG plants. Clamp-on and portable ultrasonic meters check water, hydrocarbon liquid and utility lines without cutting the pipe. Aluminum oxide and TDLAS moisture analyzers watch dehydration units, gas pipelines, hydrogen and industrial gas streams. The manufacturer also names chemical processing, energy and water and wastewater among its markets, which matches what GCC operators ask us for.

Panametrics products we list

Family Examples
Flowmeters AT600 AquaTrans Clamp-On Ultrasonic Wate…, DigitalFlow GM868 General-Purpose Gas Ul…, GF868 DigitalFlow Flare Gas Ultrasonic F…, PT900 TransPort Portable Ultrasonic Flow…, XGM868i DigitalFlow Gas Ultrasonic Flow…, XMT1000 Liquid Flow Ultrasonic Transmitter
Gas Analyzer Systems Aurora TDLAS Moisture Analyzer for Natur…, HygroPro II Aluminum Oxide Moisture Tran…, moisture.IQ Multichannel Trace Moisture…

Ordering Panametrics equipment: what we need

A Panametrics model is a long configuration string, and the transducers or probes are ordered separately. Please send the full model and serial number of the electronics, the transducer or moisture probe part number, pipe size, schedule and material, fluid, pressure and temperature, flow range, hazardous area approval and output or protocol. For a flare meter add the flare gas composition range and velocity range. For moisture, give the dew point range and whether sample system components are required.

Facts checked against GE's 2002 acquisition release, Crane Company's January 2026 completion release and Irish press, October 2026.

FAQ

Questions about the Panametrics PanaFlow LC Clamp-On Ultrasonic Liquid

Answers from our engineering team on installation, compatibility and integration.

01What pipe sizes does PanaFlow LC cover?
The datasheet gives 0.75 in to 300 in (20 mm to 7.5 m) with wall thickness up to 4 in (100 mm); other thicknesses on consultation.
02Which transmitter is used with PanaFlow LC?
The XMT1000LC transmitter, configurable for one, two or three paths with HART or Foundation Fieldbus options.
03What is the Automatic Tracking Window in PanaFlow LC?
ATW dynamically sweeps the receiver window when fluid sound speed changes, so flow is measured even when the fluid properties are unknown.
04Which transducer suits hot process lines on PanaFlow LC?
C-RS HT handles up to 230 C (446 F) and the C-ET covers -200 to 400 C (-328 to 752 F).
05Can PanaFlow LC be used in a SIL application?
An optional SIL certified configuration exists, using a SIL 4-20 mA output and SIL calibration certificate codes in the order string.