Brand:

Servomex S2500980B BaF2 Window for SpectraExact 2500

Description

Servomex S2500980B: barium fluoride window for the 2500 cell

Servomex S2500980B is the barium fluoride, or BaF2, optical window listed in Table 6.5 of the SERVOTOUGH SpectraExact 2500 series manual. A 2500 is a through-beam infrared analyser: the beam leaves the source end, passes through the sample cell, and reaches the detector end, with a single optical axis and no alignment adjustment. The sample cell is a thick 316 stainless steel body closed by two windows, each 6 mm thick, and S2500980B is the BaF2 version of that window. Because every application is specified individually, the manual tells users to see the Manufacturing Data Sheet at the front of the manual to learn which window material was fitted.

This page is for maintenance and purchasing staff who must match the window to the analyser build. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Why barium fluoride is chosen over the standard window

The manual states that the standard window material chosen by the manufacturer is calcium fluoride, which is non-toxic and reasonably robust. Some applications need something else: barium fluoride, zinc selenide and others are used where the sample chemistry or the optical band demands it. S2500980B is therefore a deliberate choice recorded on the data sheet, not a general-purpose replacement. If your analyser was supplied with CaF2, the correct part is S2500980A.

Parameter Value
Part number S2500980B
Material Barium fluoride (BaF2)
Listed in Table 6.5 Window Spares
Window thickness 6 mm
Cell body 316 stainless steel as standard
Retaining parts on removal Locking ring, 5 wavy washers, spacer, O ring, PTFE gasket
Tools Special Tools Kit S2500979 and hand aspirator 2387-0514
Operating temperature of analyser 0 to 55 C
Cell cleaning trigger Reference detector signals below 50 percent of initial
Toxicity note Barium fluoride listed as a toxic window material

How S2500980B differs from the other windows

  • S2500980A, calcium fluoride: the standard, non-toxic and reasonably robust window.
  • S2500980C, zinc selenide: toxic, and attacked by acid condensate; selenium metal can form.
  • S2500980D, quartz; S2500980E, glass; S2500980G, sapphire: used for other wavelength bands and duties.
  • S2500980B, barium fluoride: toxic, grown from optical single crystal, subject to brittle fracture.

Handling rules from the manual

The windows are normally ground from optical-grade single crystal, are described in the manual as potentially extremely expensive, may carry anti-reflective coatings, and can be damaged by brittle fracture. Keep them free from dirt, scratches, grease and fingerprints, and wear cotton gloves or finger cots. Clean with cotton buds or lens tissue, detergent or a solvent such as isopropanol, never with abrasive compounds. Treat solvents as a hazard in their own right and follow local standards.

Changing the window: sequence for S2500980B

Remove the end bosses first, then the cell. At each end unscrew the locking ring using the cell key from Special Tools Kit S2500979, take out the five wavy washers, the spacer and the O ring without damaging the window, then seal the outlet with the cell upright and apply gentle pressure through a hand aspirator, part 2387-0514, on the inlet so that the window rises squarely. Remove the PTFE gasket. The O ring spacer is threaded internally, and the kit provides an extractor. Reverse the process with new O rings and seal kit items. Tighten the locking ring in stages until its face meets the cell body with no gap; where Teflon O rings are used, expect high torque and pause between stages.

Leak check and return to service

After assembly, leak check the cell with a manometer before putting it back on the analyser; do not submerge it or fill it with water. Reinstall, reconnect the cell thermocouple and heater leads where fitted, refit the ferrite close to the suppressor bracket, and flush the end bosses with clean dry nitrogen before new scrubbers are screwed in. Then run the zero and span routines.

Seal kits that go with S2500980B

Order the matching seal kit at the same time: S2500982A for Viton plus PTFE or S2500982B for Chemraz, and keep a hand aspirator in stock.

Typical applications for BaF2 windows

Applications are specified individually, so the data sheet is decisive. In general terms, 2500 analysers are used in petrochemical, refining, gas processing and power plant duties around Oman and the GCC for gas-phase and liquid-phase infrared measurements, where the cell material must suit both the wavelength and the sample.

Spare strategy

The recommended spares table lists two windows for one to three analysers over two years and four windows for four to nine; the part is “refer to application” because it depends on the material fitted.

For context on the whole instrument: the 2500 housing is up to 1620 mm long and at least 620 mm, 241 mm high with about 500 mm clearance needed to open the end covers, 284 mm wide, and weighs from 25 kg to 50 kg depending on the cell. Operating humidity is 0 to 95 percent non-condensing, storage temperature minus 25 to plus 70 degrees Celsius, and altitude up to 3000 m. The cell, once the window is replaced, must also stay free from solvent residues and finger grease before reassembly, since residue on the BaF2 surface lowers transmission and shows up as a falling reference signal.

Documents and quotation

The Servomex SpectraExact 2500 series manual, part number 02500005D, is the document we attach for Servomex S2500980B; its section 6 spares tables are the source of the part number and description. Please tell us the window material shown on the Manufacturing Data Sheet at the front of your manual, since the windows are application specific. To request a quotation, send S2500980B, the quantity, the analyser serial number and the Final Specification Sheet reference if you have it, and your delivery location in Oman or the GCC. Each RFQ is answered with availability and lead time.

Other Models in the Servomex 2500 Range

Seven Star LLC supplies models from the Servomex 2500 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Servomex S2500931A Long Wave ZnSe Source Unit for SpectraExact 2500Gas Analyzer SystemsView details
Servomex S2501905C CVDFET Detector Unit for SpectraExact 2500Gas Analyzer SystemsView details
Servomex S2500980B BaF2 Window for SpectraExact 2500Gas Analyzer SystemsYou are viewing this model
Servomex S1200922 CW Boss Scrubber H2O/CO2 for SpectraExact 2500Gas Analyzer SystemsView details
Datasheets & Documents
  • PDF Datasheet Servomex S2500980B BaF2 Window for SpectraExact 2500 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Servomex is a British specialist in gas analysis, founded in 1952 by Richard Steel, John Crockett and Ronald Mudie; the name comes from servomechanism. It first made electronic products, then built its first paramagnetic oxygen analyser in 1961 after work with Charles Munday on a paramagnetic sensor. Servomex is based in Crowborough, East Sussex, and is part of Spectris.

Seven Star LLC lists Servomex process, combustion, emissions and portable gas analyzers, plus accessories, and sources them for refineries, petrochemical plants and industrial gas producers in Oman.

SERVOMEX company profile

Founded 1952, United Kingdom
Founders Richard Steel, John Crockett and Ronald Mudie
Headquarters Jarvis Brook, Crowborough, East Sussex
Ownership Spectris plc, since 1999
Key technologies Paramagnetic oxygen sensing (1961), infrared analysis (1969), zirconia oxygen sensors (1981)
Product families MultiExact and SERVOPRO MultiExact analysers, SERVOTOUGH OxyExact and Oxy 1800 oxygen analysers, SERVOTOUGH Laser 3 Plus TDL analysers, SERVOFLEX portable analysers, zirconia combustion analysers

Milestones

  • 1952: Servomex is founded.
  • 1961: The first Servomex paramagnetic oxygen analyser is introduced.
  • 1981: Servomex introduces zirconia oxygen sensors.
  • 1999: Spectris acquires Servomex.

Servomex analyzer families listed

Servomex groups its analyzers under family names that indicate where they can be used. SERVOTOUGH covers analyzers built for hazardous areas and field mounting, SERVOPRO covers units for general purpose areas and analyzer houses, and SERVOFLEX is the portable line. On this page:

  • SERVOTOUGH OxyExact 2200: paramagnetic oxygen analyzer for process control and safety
  • SERVOTOUGH SpectraExact 2500: photometric analyzer for process gas components
  • SERVOTOUGH Laser 3 Plus: compact tunable diode laser analyzer for combustion
  • SERVOPRO 4900 Multigas: multi-component analyzer for emissions monitoring
  • SERVOPRO NanoTrace DF-550E: ultra-trace oxygen analyzer for high purity gases
  • SERVOFLEX Micro i.s. 5100: intrinsically safe portable oxygen analyzer

A flow alarm relay box for the 2700 flue gas analyzer is also listed.

Where Servomex gas analyzers are used

Typical duties are oxygen measurement for inerting and blanketing, vapor recovery and flare header safety, combustion control on fired heaters and reformers, purity control in air separation and electronic gases, and continuous emissions monitoring. In the GCC the main users are refining, petrochemicals, fertilizer, LNG and industrial gas plants.

SERVOMEX products we list

Family Examples
Gas Analyzer Systems SERVOPRO 4900 Multigas Analyzer, SERVOPRO NanoTrace DF-550E Ultra-Trace O…, SERVOTOUGH Laser 3 Plus Combustion TDL G…, SERVOTOUGH OxyExact 2200 Oxygen Analyzer, ServoTough SpectraExact 2500 Gas Analyzer
Portable Test & Measurement Micro i.s. 5100 Portable Oxygen Analyzer
Gas Analyzer Accessories Tough Flue Gas 2700 Flow Alarm Relay Box

Ordering Servomex analyzers and spares: what we need

A Servomex gas analyzer is built to an order code that fixes the measured gas, range, sample wetted materials, outputs and hazardous area approval. For replacements and spare parts, send the model, the serial number and the order code from the data plate. For a new Servomex oxygen analyzer or multigas unit, send the full stream composition, the component and range to be measured, sample pressure and temperature, the area classification, power supply and communication needs. We check the configuration against Servomex documentation before quoting.

Facts checked against Servomex's own 70-year history and company profiles, October 2026.

FAQ

Questions about the Servomex S2500980B BaF2 Window for SpectraExact 2500

Answers from our engineering team on installation, compatibility and integration.

01What is Servomex S2500980B?
S2500980B is the barium fluoride (BaF2) cell window listed in the Window Spares table of the SpectraExact 2500 series manual.
02Is BaF2 hazardous to handle?
The manual names barium fluoride among the toxic window materials, so it must be handled under the relevant local standards, with cotton gloves or finger cots to keep the optics clean.
03How thick are the cell windows?
The construction description gives each optical window as 6 mm thick.
04When should the cell windows be replaced?
The manual advises removing the cell for cleaning when reference detector signals fall below 50 percent of their initial values; windows are replaced if corrosion or pitting is the cause.
05Which other windows exist in the same table?
CaF2 S2500980A, ZnSe S2500980C, Quartz S2500980D, Glass S2500980E and Sapphire S2500980G.