Brand: Panametrics
Panametrics PanaFlow PF8M-Z2G Two-Path Ultrasonic Gas Flowmeter
Description
PF8M-Z2G PanaFlow gas meter with two paths
The code PF8M-Z2G belongs to the Panametrics PanaFlow ZxG gas range: a dual-path wetted ultrasonic gas flowmeter system that combines an all-cast flanged body with an XGM868i transmitter. The Panametrics datasheet describes the series as two models, the single-path Z1G and the two-path Z2G, and the prefix PF8M selects the XGM868i electronics (PF8F would instead select the XGF868i flare transmitter). The meter was designed for gases that carry heavy impurities and condensate, such as biogas, natural gas production, vent and waste gas, shale gas, coal-seam gas wellhead flow, vapor recovery and fuel gas. Because the body is cast and machined, with no welds to disturb the flow, it holds accuracy down to low flow.
Why PF8M-Z2G suits dirty gas
- Ultra-high-power T19 transducers with improved sound isolation for heavy condensate and impurities.
- No obstruction, no moving parts and no pressure drop, so nothing to clog, wear or tune.
- Measuring range of 0.5 to 200 ft/s (0.15 to 60 m/s) in sizes 2 in to 8 in, bidirectional.
- Accuracy of 1% of reading for the two-path Z2G above 5 ft/s, compared with 1.5% for Z1G.
- Percent-methane-in-carbon-dioxide software available for biogas.
- Air calibration with certificate; meter body certified to PED Cat III Module B+C2, CRN and NACE.
PF8M-Z2G performance and electrical data
| Parameter | Z2G (two path) | Z1G (one path, for comparison) |
|---|---|---|
| Velocity accuracy, 5 ft/s to Qmax | plus or minus 1% | plus or minus 1.5% |
| Sensitivity, 0.5 to 5 ft/s | 0.05 ft/s (0.015 m/s) | 0.075 ft/s (0.02 m/s) |
| Repeatability | 0.5% of reading | 0.5% of reading |
| Maximum velocity at 12 in | 150 ft/s (45 m/s) | 130 ft/s (39 m/s) |
| Maximum velocity at 16 in | 100 ft/s (30 m/s) | 80 ft/s (24 m/s) |
| Body sizes | 2 in to 16 in (50 to 400 mm) | |
| Body materials | SA352 LCC carbon steel, SA351 CF8M stainless, SA995 duplex | |
| Process temperature | -40 to 185 F (85 C) local mount; to 302 F (150 C) remote mount | |
| Power | 100 to 240 VAC or 12 to 28 VDC; 20 W maximum | |
| I/O | Two 4-20 mA outputs, two 4-20 mA inputs for pressure and temperature; optional pulse, frequency, relays | |
| Hazardous area | Class I Div 1 B,C,D; ATEX II 2 G Ex db IIB+H2 T6 to T3 Gb; IECEx | |
How PF8M-Z2G differs from other ZxG variants
Choosing the Z2G over the Z1G buys two paths, which cuts the accuracy figure from 1.5% to 1% and improves the low-flow sensitivity from 0.075 to 0.05 ft/s, and it raises the maximum velocity in large bodies, for instance from 100 to 130 ft/s at 14 in. The price of that is a more complex port arrangement; for 2 in and 3 in meters the dual-plane diametric layout is used. The PF8M prefix uses the XGM868i gas transmitter with a 2 by 16 character display, while PF8F is the flare transmitter variant.
Reading the PF8M-Z2G order string
The format is AAAA BBB CC D EE FFF G H I J KKKK LL M N O P Q R S T U Z. After PF8M and Z2G comes body size (02 to 16), flange (1 to 3 for ASME 150 to 600 WN, E to J for PN10 to PN60), body material (CC, S6, SD), schedule (STD, 040, 0XS, 080, 10S, 40S, 80S, CUS), system rating (A, C with CRN, P for PED), paint, documentation (0, 1 NDE, 2 PMI plus NDE), o-ring (V Viton, E EPDM, M Markez FFKM), electronics mounting (000L local to 85 C, 0R25, 0R50 or R100 remote with 25, 50 or 100 ft cable to 150 C), aluminum or SS316 enclosure, cable entry (3/4 in NPT or M20), power, I/O option (F, T or A), and communication (2 Modbus RS485, 3 HART, 4 Foundation Fieldbus).
Fitting PF8M-Z2G in Oman gas lines
The bolt-in cast flanged body is aimed at gathering lines, vapor recovery skids, biogas plants at wastewater works and fuel gas headers where the gas is wet or contaminated. A straight run of about 20 diameters upstream and 10 downstream, a Reynolds number above 5000 and single-phase gas underpin the stated accuracy; where out-of-plane elbows induce swirl the datasheet suggests extra straight run, flow conditioning or a factory CFD evaluation.
Practical points before ordering PF8M-Z2G: confirm whether the plant needs Viton, EPDM or Markez FFKM o-rings in the transducer ports, since wet sour gas or aromatic condensate may attack standard elastomers. Decide on the pressure and temperature inputs early, because the standard two 4-20 mA inputs are reserved for those transmitters and the flow computer needs them to report standard volume. Specify the documentation level that your inspection team expects, from no NDE paperwork up to PMI of wetted parts. Finally, state the cable entry type (3/4 in NPT or M20) so the junction hardware matches site conduit practice, and the communication protocol that the control room reads.
Commissioning and care
Electronics ordered with the meter are programmed with the application setup. Local electronics are not recommended above 185 F (85 C). Provide 12 in (305 mm) of service clearance on each side and above the body, as drawings 712-2158 for local mount and 712-2160 for remote mount indicate. A 3 in two-path 150 lb flowcell weighs about 66.7 kg, rising to 72.9 kg at 600 lb, so lifting equipment should be planned. No filters, strainers or recalibration are required during normal service.
Supplier notes
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We help match PF8M-Z2G order strings to your line data.
Documents and quotation
A manufacturer datasheet for PF8M-Z2G is supplied. Send an RFQ giving the full PF8M-Z2G order string, line size, flange rating, gas composition and quantity.
Datasheets & Documents
- Datasheet Panametrics PanaFlow PF8M-Z2G Two-Path Ultrasonic Gas Flowmeter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Panametrics is an American maker of ultrasonic flowmeters and moisture, oxygen and gas analysers. It was founded in 1960 and was based in Waltham, Massachusetts, when GE bought it in 2002. It later became a Baker Hughes business, and since 1 January 2026 it has belonged to Crane Company. Its long-running site in Shannon, Ireland, opened in 1973.
Seven Star LLC lists Panametrics flowmeters and analyzers for buyers in Oman: DigitalFlow gas and flare meters, clamp-on and portable liquid meters, and trace moisture analyzers for natural gas and process gases. We are an independent supplier, so each inquiry is checked against the manufacturer's order string before a quotation goes out.
Panametrics company profile
| Founded | 1960, Massachusetts, USA |
|---|---|
| Main sites | Billerica, Massachusetts, and Shannon, Ireland (since 1973) |
| Ownership | Crane Company since 1 January 2026; previously GE (from 2002) and Baker Hughes |
| Key technology | Transit-time ultrasonic flow measurement and aluminium oxide moisture sensing |
| Product families | TransPort PT900 portable and DigitalFlow fixed ultrasonic flowmeters for liquid, gas and flare gas, aluminium oxide moisture probes and hygrometers, Aurora laser moisture analysers, XMO2 oxygen and XMTC thermal conductivity transmitters |
Milestones
- 1960: Panametrics is founded.
- 1973: The Shannon, Ireland, site is established.
- 2002: GE acquires Panametrics.
- 2026: Crane Company completes its purchase of Baker Hughes' Precision Sensors & Instrumentation, including Panametrics.
Panametrics product families on this page
The listed items follow the manufacturer's own grouping:
- Gas and flare flow: DigitalFlow GF868 flare gas meter, GM868 and XGM868i gas flow transmitters
- Liquid flow: XMT1000 transmitter, AT600 AquaTrans clamp-on meter, TransPort PT900 portable meter
- Moisture: moisture.IQ multichannel analyzer, HygroPro II aluminum oxide transmitter, Aurora TDLAS analyzer for natural gas
Older units may carry GE Panametrics or GE Sensing on the nameplate. They belong to the same product lines, and the model string is read the same way.
Where Panametrics flowmeters and moisture analyzers are used
Flare meters report flared volumes on production sites, refineries and LNG plants. Clamp-on and portable ultrasonic meters check water, hydrocarbon liquid and utility lines without cutting the pipe. Aluminum oxide and TDLAS moisture analyzers watch dehydration units, gas pipelines, hydrogen and industrial gas streams. The manufacturer also names chemical processing, energy and water and wastewater among its markets, which matches what GCC operators ask us for.
Panametrics products we list
Ordering Panametrics equipment: what we need
A Panametrics model is a long configuration string, and the transducers or probes are ordered separately. Please send the full model and serial number of the electronics, the transducer or moisture probe part number, pipe size, schedule and material, fluid, pressure and temperature, flow range, hazardous area approval and output or protocol. For a flare meter add the flare gas composition range and velocity range. For moisture, give the dew point range and whether sample system components are required.
Facts checked against GE's 2002 acquisition release, Crane Company's January 2026 completion release and Irish press, October 2026.
FAQ
Questions about the Panametrics PanaFlow PF8M-Z2G Two-Path Ultrasonic
Answers from our engineering team on installation, compatibility and integration.
01What is the difference between Z1G and Z2G in the PanaFlow ZxG range?
Z1G has one path and 1.5 percent accuracy above 5 ft/s; Z2G has two paths with 1 percent accuracy and finer low-flow sensitivity.
02What does the PF8M prefix mean on PF8M-Z2G?
It denotes the PanaFlow gas ultrasonic system with the XGM868i transmitter; PF8F instead uses the XGF868i.
03Can PF8M-Z2G measure biogas?
Yes. Biogas is a listed application, and optional percent-methane-in-carbon-dioxide software is available for it.
04Why are there two temperature limits for PF8M-Z2G?
Local electronics are limited to 85 C process temperature, while remote-mounted electronics allow up to 150 C.
05What straight run does PF8M-Z2G need?
The accuracy statement assumes about 20 diameters upstream and 10 downstream, a Reynolds number above 5000 and single-phase gas.