Brand:

APC SYPM4KI Symmetra LX 4kVA Power Module 220/230/240V

Description

Role of the SYPM4KI in a power protection layout

The APC SYPM4KI is an uninterruptible power supply from the Symmetra Power Module range, rated at 4000 VA (2800 W).

It is fed from 230 V / 400 V 3 phases and supplies 230 V. The recorded mounting mode is not rack-mountable.

The listed ratings of 4000 VA and 2800 W correspond to a power factor of 0.7. Size the load against the watt rating as well as the VA rating, and keep margin for future equipment.

Technical specifications

Parameter Specification
Part number SYPM4KI
Main Input Voltage 230 V / 400 V 3 phases
Product or component type Power module
Other Input Voltage 220 V / 240 V / 380 V / 415 V
Main Output Voltage 230 V
Other Output Voltage 220 V / 240 V
Rated power in W 2800 W
rated power in VA 4000 VA
Output connector type Hard wire 3-wire (H N + E) for 1 zone(s)
Number of rack unit 4U
Provided equipment Installation guide
Range of product Symmetra Power Module
Height 150 mm
Width 250 mm
Depth 565 mm
Net weight 15 kg
Mounting location Front
Mounting preference No preference
Mounting mode Not rack-mountable
USB compatible No
Network frequency 45…65 Hz auto-sensing
Input voltage limits 155…276 V 1:1 / 290…480 V 3:1
Input Power Factor at Full Load 0.98
Maximum configurable power in W 2800 W
Output frequency 50 Hz +/- 0.1 % for 50 Hz nominal unsynchronised / 60 Hz +/- 0.1 % for 60 Hz nominal unsynchronised
Crest factor Up to 5 : 1
UPS type Double conversion online
Wave type Sine wave
Number of battery filled slots 0
Number of battery free slots 0
Additional information Configurable for 220 : 230 or 240 nominal output voltage
Product certifications C-Tick / CE / GOST / VDE
Standards EN 50091-1 / EN 50091-2 / EN 55022 class A / EN 55024 / EN 60950 / IEC 60950
Ambient air temperature for operation 0…40 °C
Relative humidity 0…95 %
Operating altitude 0…10000 ft
Ambient air temperature for storage -15…45 °C
Storage Relative Humidity 0…95 %
Storage altitude 0…4572 m
Acoustic level 62 dBA
Warranty (in months) 24

Electrical interface and runtime notes

Output connections: Hard wire 3-wire (H N + E) for 1 zone(s). Input frequency: 45…65 Hz auto-sensing.

Load sizing should be checked against both the VA and the watt rating, and runtime depends on the connected load, battery condition and ambient temperature. Confirm these points against the product documents before ordering.

Physical data and environment

Dimensions are 150 mm x 250 mm x 565 mm (H x W x D), and the unit weighs 15 kg.

Listed operating limits: operating temperature 0…40 °C; relative humidity 0…95 %; operating altitude 0…10000 ft; acoustic level 62 dBA.

Certifications: C-Tick / CE / GOST / VDE. Standards: EN 50091-1 / EN 50091-2 / EN 55022 class A / EN 55024 / EN 60950 / IEC 60950. Warranty recorded by APC (months): 24.

Further electrical values recorded for the APC SYPM4KI include: input power factor at full load: 0.98; crest factor: Up to 5 : 1. Use these figures when sizing upstream protection and cabling, and confirm them against the installation documents for the exact variant.

The mounting mode is listed as not rack-mountable. The unit measures 150 mm x 250 mm x 565 mm (H x W x D) and weighs 15 kg, so check the available space and the floor or rack loading before delivery. It occupies 4U of rack space. Listed environmental limits: operating temperature 0…40 °C; relative humidity 0…95 %; altitude 0…10000 ft. Equipment rooms in the Gulf region often run warm, so leave ventilation clearance and keep the unit away from direct heat sources.

Certifications listed: C-Tick / CE / GOST / VDE. The warranty period recorded in the product data is 24 months. If a project requires certificates or test reports, include that request with the quotation request.

The SYPM4KI within the APC Symmetra LX range

Symmetra LX is a modular single-phase UPS built from hot-swappable power modules and battery modules in a rack or tower frame. With N+1 redundancy a failed module can be replaced while the load stays protected, and capacity or runtime can be raised by adding modules instead of replacing the whole UPS.

A power module supplies a slice of the total UPS capacity in a modular APC system. Running one module more than the load needs (N+1) gives redundancy, and a failed or ageing module can be exchanged while the system keeps the load on protected power.

In the product data for the APC SYPM4KI, it is rated 4000 VA and 2800 W; it occupies 4U rack unit(s). These values are the starting point for matching it to the rest of the installation.

Using the SYPM4KI in Gulf climate and grid conditions

The output can be set to 240 V, which matches the nominal 240 V single-phase supply in Oman. The listed operating temperature tops out at 40 °C. Summer shade temperatures in Muscat, Sohar and the interior regularly pass 45 °C, so the equipment belongs in an air-conditioned room or cabinet rather than an open plant area. Fine dust inland and humid, salty air on the coast are hard on electronics, so a sealed room, clean filters and periodic inspection of fans and terminals are part of a reliable installation.

Ordering checklist for the SYPM4KI

The following details help confirm compatibility before a quotation is issued:

  • The UPS model and serial number the item will be used with
  • The quantity needed, including any spares to keep on site
  • Rack, room or panel details where the item will be installed
  • Any documents or certificates required for the project
  • The delivery location in Oman (for example Muscat, Sohar, Duqm or Salalah) or elsewhere in the GCC, and the required date

Other APC UPS systems, batteries and accessories and Schneider Electric equipment can be combined in one quotation.

Documents and quotation

The user guide for the SYPM4KI is hosted on this page under Documents so the wiring, installation and operating details can be reviewed before ordering.

The single-unit shipping package is listed as 43.9 cm (height) x 33 cm (width) x 56.5 cm (length) with a packed weight of 18.18 kg. Use these values when planning freight, lifting and receiving space.

To order, submit the part number SYPM4KI, the quantity and the delivery location. Related items are grouped under UPS and Batteries. Seven Star LLC is an independent supplier based in Muscat and answers with availability and a quotation.

Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

APC is Schneider Electric's brand for uninterruptible power supplies, power distribution units, cooling and racks for IT and control systems. American Power Conversion was founded in 1981 by three engineers from MIT's Lincoln Laboratory and grew into one of the largest UPS makers in the world. Schneider Electric completed its acquisition of APC on 14 February 2007, combined it with MGE UPS Systems, and since 2011 APC has been a product brand of Schneider Electric.
Seven Star LLC lists APC uninterruptible power supplies from desktop Back-UPS units to modular Symmetra systems, together with battery packs and network cards, and sources them for sites in Oman.

APC company profile
Founded1981, USA, as American Power ConversionFoundersThree engineers from MIT Lincoln LaboratoryOwnershipSchneider Electric since 14 February 2007; an APC by Schneider Electric product brand since 2011Product familiesBack-UPS, Easy UPS, Smart-UPS line-interactive, Smart-UPS On-Line SRT and SRV, Galaxy three-phase UPS, rack PDUs, NetShelter racks, network management cards and EcoStruxure IT software

Milestones
1981: American Power Conversion is founded by three MIT Lincoln Laboratory engineers.2006: Schneider Electric announces the acquisition of APC on 30 October.2007: The acquisition is completed on 14 February; APC is combined with MGE UPS Systems.2011: APC becomes a product brand within Schneider Electric.

APC UPS families on this page

APC names its UPS lines by topology and size:

Back-UPS and Back-UPS Pro: line-interactive units for workstations and small loads, such as BX1600MI-MS and BR1600MISmart-UPS: line-interactive models with sine wave output, including SMT750I, SMC1000IC and the Smart-UPS X SMX3000HV with its SMX120BP external battery packSmart-UPS SRT and Smart-UPS RT: online double-conversion units, for example SRT2200XLI, SRT3000XLI, SRT5KRMXLI and SURT8000XLIEasy UPS Online: SRV2KILSymmetra LX and Symmetra PX: modular, scalable systems for larger loads

The AP9641 Network Management Card 3 adds remote monitoring to UPS models with a SmartSlot.

Where APC UPS systems are used

In industrial plants across the GCC, APC UPS units back up DCS and PLC cabinets, operator stations, SCADA servers, telecom racks, fire and gas panels and analyzer shelters. Online double-conversion models are normally chosen for control systems because the load is always fed through the inverter. Line-interactive units suit office IT and less critical loads.

APC products we list
FamilyExamplesUPS and BatteriesAP9641 Network Management Card 3, BR1600MI Back-UPS Pro 1600VA/960W, BX1600MI-MS Back-UPS 1600VA Tower UPS, SMC1000IC Line-Interactive UPS 1000VA 600W, SMC1500I Smart-UPS C 1500VA/900W, SMT750I Smart-UPS 750VA/500W Line-Interactive, SMX120BP Smart-UPS X 120V External Battery, SMX1500RMI2U Smart-UPS X 1500VA Rack/Tower and 9 more

Ordering APC UPS units and parts: what we need

Send the full SKU, for example SRT3000XLI, and not only the VA rating. The letters carry meaning: an I in the suffix marks a 230 V international model, XL an extended-run version that accepts external battery packs, and RM a rack-mount form. For a new requirement, give load in watts, input and output voltage, required runtime, tower or rack format, and the plug or hardwire arrangement. For batteries, send the UPS SKU and serial number so the correct replacement battery cartridge can be found in APC documentation.

Replacement batteries, battery packs and spares
Most APC service work is battery work. APC Replacement Battery Cartridges, sold under RBC and APCRBC numbers, are sets of sealed valve-regulated lead-acid blocks that arrive pre-wired with the connectors for the UPS models they are listed for, so a weak battery can be changed as one unit and, on hot-swap models, without switching the load off. Some newer cartridges carry an -LI suffix for lithium-ion versions. External battery packs extend runtime on XL and SRT models, and are chained to the UPS through the battery connector on the rear panel. To find the right cartridge, send the UPS SKU and serial number; the same UPS can use different cartridges across hardware revisions.
Modular and three-phase APC systems
Symmetra LX and Symmetra RM: single-phase modular UPS frames with hot-swappable power modules, battery modules and intelligence modules, so a failed module can be exchanged while the load stays on protected power.Symmetra PX: three-phase modular UPS for data rooms, built from power modules with N+1 redundancy and battery modules for runtime.Smart-UPS VT: three-phase double-conversion UPS for small data rooms and technical buildings.Silcon: large three-phase UPS based on delta conversion, still running in many plants and data centres; spare part kits are listed in levels (SPL1 to SPL4) so sites can hold the parts that match their service plan.Easy UPS On-Line (SRV): cost-focused double-conversion units, many with external battery pack support.
APC UPS in Oman and GCC conditions
Oman supplies 240 V single-phase and 415 V three-phase at 50 Hz, so international models with an I suffix (230 V nominal, adjustable to 240 V on most Smart-UPS units) are the usual choice. Heat is the main enemy: most APC UPS units are rated for operation up to 40 °C, while summer shade temperatures in Muscat and the interior pass 45 °C, and a lead-acid battery loses roughly half its service life for every 10 °C above 25 °C. Install UPS and batteries in a cooled room, keep filters clean in dusty inland sites, and size the standby generator with margin for UPS input and battery charging current.
All APC UPS systems, batteries and accessories on this site are grouped under UPS and Batteries, and the wider Schneider Electric range can be quoted together with them.

Facts checked against APC by Schneider Electric's published history, October 2026.

Browse APC products by category: UPS and Batteries.
Need a replacement battery for an APC UPS you already run? Use our APC UPS replacement battery finder to match the model to its official RBC cartridge.

FAQ

Questions about the APC SYPM4KI Symmetra LX 4kVA Power Module

Answers from our engineering team on installation, compatibility and integration.

01What is the rated power of the APC SYPM4KI?
The APC SYPM4KI is rated at 4000 VA / 2800 W.
02What input and output voltage does the APC SYPM4KI use?
The input is 230 V / 400 V 3 phases at 45...65 Hz auto-sensing and the output is 230 V.
03What are the dimensions and weight of the APC SYPM4KI?
The listed dimensions are 150 mm x 250 mm x 565 mm (H x W x D) and the weight is 15 kg.
04What operating conditions apply to the APC SYPM4KI?
Listed limits: operating temperature 0…40 °C; relative humidity 0…95 %.
05How can I request a quotation for the APC SYPM4KI?
Send the part number SYPM4KI with quantity and delivery location through the RFQ form. Seven Star LLC is an independent supplier in Muscat and replies with availability and a quotation.