Brand:

APC SRTG192XLBP Smart-UPS RT 192V 5Ah Battery Pack

Description

What the SRTG192XLBP is for

The APC SRTG192XLBP is a battery product for APC UPS systems, specified at 192 V.

Chemistry: lead-acid battery. Each unit measures 8.7 cm x 44 cm x 62 cm (H x W x D) and weighs 39.4 kg.

Technical specifications

Parameter Specification
Part number SRTG192XLBP
Number of rack unit 2U
Battery type Lead-acid battery
Provided equipment Installation guide
Colour Black
Height 8.7 cm
Width 44 cm
Depth 62 cm
Net weight 39.4 kg
Mounting mode Rack-mounted with kit
Device mounting Stand alone battery stack
Number of battery filled slots 4
Number of battery free slots 0
Number of battery replacement quantity 2
Additional information Replace all batteries in operation together (UPS internal and external batteries) all-at-once
Battery voltage 192 V
Ambient air temperature for operation 0…40 °C
Relative humidity 0…95 %
Operating altitude 0…6600 ft
Ambient air temperature for storage -15…45 °C
Storage Relative Humidity 0…95 %
Storage altitude 0…15240 m

Compatibility and replacement notes

Battery voltage: 192 V.

Battery replacement should be matched to the exact UPS model named in the APC documentation, because voltage, connector and cartridge count differ between systems. Used batteries must be recycled according to local regulations.

Physical data and environment

Dimensions are 8.7 cm x 44 cm x 62 cm (H x W x D), and the unit weighs 39.4 kg. Colour: black.

Listed operating limits: operating temperature 0…40 °C; relative humidity 0…95 %; operating altitude 0…6600 ft.

The APC SRTG192XLBP is listed with type lead-acid battery, voltage 192 V. Replacement batteries should be fitted as a complete set of the same type and age, because mixing old and new cells shortens the life of the whole string. Fit and wire the cartridge exactly as shown in the installation sheet, and recycle used batteries according to local regulations.

The unit measures 8.7 cm x 44 cm x 62 cm (H x W x D) and weighs 39.4 kg, so check the available space and the handling requirements before delivery. It occupies 2U of rack space. Listed environmental limits: operating temperature 0…40 °C; relative humidity 0…95 %; altitude 0…6600 ft. Store and operate the battery within these limits, because heat shortens service life.

The SRTG192XLBP within the APC Smart-UPS RT range

Smart-UPS RT models are an earlier generation of APC double-conversion on-line UPS in rack/tower convertible housings with external battery pack support. Many are still in service in server rooms and control buildings, which is why like-for-like units, batteries and accessories for the RT range remain in demand.

An external battery pack adds runtime by connecting additional battery strings to the DC bus of a compatible UPS. The pack voltage and connector must match the UPS, and the UPS should be told how many packs are connected so that runtime estimates and charging stay correct. Packs are normally daisy-chained, so the total runtime can be built up step by step as the load or the outage risk of the site grows.

In the product data for the APC SRTG192XLBP, its battery technology is listed as lead-acid battery; the battery voltage is 192 V; it occupies 2U rack unit(s). These values are the starting point for matching it to the rest of the installation.

Site conditions in Oman and the GCC for the SRTG192XLBP

The listed operating temperature tops out at 40 °C. Summer shade temperatures in Muscat, Sohar and the interior regularly pass 45 °C, so the equipment belongs in an air-conditioned room or cabinet rather than an open plant area. Battery temperature has the biggest effect on service life: as a rule of thumb, the life of a valve-regulated lead-acid battery roughly halves for every 10 °C above 25 °C, so a room held at 20 to 25 °C pays back in fewer battery replacements. Coastal sites such as Muscat, Sohar and Duqm add humidity and salt to the air, and inland sites add fine dust, so keep the room sealed and clean and check filters and fans at every service visit. At 39.4 kg the unit needs two people or lifting equipment for installation, and rails rather than a shelf if it goes into a rack.

Service life and maintenance of the APC SRTG192XLBP

Reliability over the years depends mostly on the environment and on routine checks. Keep the room cool and dust-free, inspect fans, filters and connections during planned visits, and review the event log for warnings. On UPS and battery systems, measure runtime under the real load from time to time and replace batteries as a complete set before the runtime falls below what the site needs.

Seven Star LLC supplies APC equipment as an independent supplier based in Muscat. Original product documents are provided where available, and the part number SRTG192XLBP can be quoted together with related batteries, accessories and spares in one enquiry.

Storage, handling and delivery of the APC SRTG192XLBP

Sealed lead-acid batteries lose charge slowly while in storage, faster at high temperature, so batteries and units with internal batteries should be stored cool, dry and upright, and recharged within the interval the manufacturer gives if they are kept for several months before use. Check the packaging and the part number label on arrival, keep the documents supplied with the item, and record the installation date so that future service intervals and warranty questions can be answered quickly. Seven Star LLC arranges delivery to project sites, warehouses and offices across Oman, and shipment to other GCC countries on request.

Information to include when ordering the SRTG192XLBP

The following details help confirm compatibility before a quotation is issued:

  • The exact UPS model the pack will be connected to
  • How many packs are already connected and how many are needed
  • The runtime target at the actual load
  • Rack or tower installation and available rack units
  • The delivery location in Oman (for example Muscat, Sohar, Duqm or Salalah) or elsewhere in the GCC, and the required date

Other APC UPS systems, batteries and accessories and Schneider Electric equipment can be combined in one quotation.

Documents and quotation

The user guide for the SRTG192XLBP is hosted on this page under Documents so the wiring, installation and operating details can be reviewed before ordering.

To order, submit the part number SRTG192XLBP, the quantity and the delivery location. Related items are grouped under UPS and Batteries. Seven Star LLC is an independent supplier based in Muscat and answers with availability and a quotation.

Datasheets & Documents
  • PDF User guide APC SRTG192XLBP User guide Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

APC is Schneider Electric's brand for uninterruptible power supplies, power distribution units, cooling and racks for IT and control systems. American Power Conversion was founded in 1981 by three engineers from MIT's Lincoln Laboratory and grew into one of the largest UPS makers in the world. Schneider Electric completed its acquisition of APC on 14 February 2007, combined it with MGE UPS Systems, and since 2011 APC has been a product brand of Schneider Electric.
Seven Star LLC lists APC uninterruptible power supplies from desktop Back-UPS units to modular Symmetra systems, together with battery packs and network cards, and sources them for sites in Oman.

APC company profile
Founded1981, USA, as American Power ConversionFoundersThree engineers from MIT Lincoln LaboratoryOwnershipSchneider Electric since 14 February 2007; an APC by Schneider Electric product brand since 2011Product familiesBack-UPS, Easy UPS, Smart-UPS line-interactive, Smart-UPS On-Line SRT and SRV, Galaxy three-phase UPS, rack PDUs, NetShelter racks, network management cards and EcoStruxure IT software

Milestones
1981: American Power Conversion is founded by three MIT Lincoln Laboratory engineers.2006: Schneider Electric announces the acquisition of APC on 30 October.2007: The acquisition is completed on 14 February; APC is combined with MGE UPS Systems.2011: APC becomes a product brand within Schneider Electric.

APC UPS families on this page

APC names its UPS lines by topology and size:

Back-UPS and Back-UPS Pro: line-interactive units for workstations and small loads, such as BX1600MI-MS and BR1600MISmart-UPS: line-interactive models with sine wave output, including SMT750I, SMC1000IC and the Smart-UPS X SMX3000HV with its SMX120BP external battery packSmart-UPS SRT and Smart-UPS RT: online double-conversion units, for example SRT2200XLI, SRT3000XLI, SRT5KRMXLI and SURT8000XLIEasy UPS Online: SRV2KILSymmetra LX and Symmetra PX: modular, scalable systems for larger loads

The AP9641 Network Management Card 3 adds remote monitoring to UPS models with a SmartSlot.

Where APC UPS systems are used

In industrial plants across the GCC, APC UPS units back up DCS and PLC cabinets, operator stations, SCADA servers, telecom racks, fire and gas panels and analyzer shelters. Online double-conversion models are normally chosen for control systems because the load is always fed through the inverter. Line-interactive units suit office IT and less critical loads.

APC products we list
FamilyExamplesUPS and BatteriesAP9641 Network Management Card 3, BR1600MI Back-UPS Pro 1600VA/960W, BX1600MI-MS Back-UPS 1600VA Tower UPS, SMC1000IC Line-Interactive UPS 1000VA 600W, SMC1500I Smart-UPS C 1500VA/900W, SMT750I Smart-UPS 750VA/500W Line-Interactive, SMX120BP Smart-UPS X 120V External Battery, SMX1500RMI2U Smart-UPS X 1500VA Rack/Tower and 9 more

Ordering APC UPS units and parts: what we need

Send the full SKU, for example SRT3000XLI, and not only the VA rating. The letters carry meaning: an I in the suffix marks a 230 V international model, XL an extended-run version that accepts external battery packs, and RM a rack-mount form. For a new requirement, give load in watts, input and output voltage, required runtime, tower or rack format, and the plug or hardwire arrangement. For batteries, send the UPS SKU and serial number so the correct replacement battery cartridge can be found in APC documentation.

Replacement batteries, battery packs and spares
Most APC service work is battery work. APC Replacement Battery Cartridges, sold under RBC and APCRBC numbers, are sets of sealed valve-regulated lead-acid blocks that arrive pre-wired with the connectors for the UPS models they are listed for, so a weak battery can be changed as one unit and, on hot-swap models, without switching the load off. Some newer cartridges carry an -LI suffix for lithium-ion versions. External battery packs extend runtime on XL and SRT models, and are chained to the UPS through the battery connector on the rear panel. To find the right cartridge, send the UPS SKU and serial number; the same UPS can use different cartridges across hardware revisions.
Modular and three-phase APC systems
Symmetra LX and Symmetra RM: single-phase modular UPS frames with hot-swappable power modules, battery modules and intelligence modules, so a failed module can be exchanged while the load stays on protected power.Symmetra PX: three-phase modular UPS for data rooms, built from power modules with N+1 redundancy and battery modules for runtime.Smart-UPS VT: three-phase double-conversion UPS for small data rooms and technical buildings.Silcon: large three-phase UPS based on delta conversion, still running in many plants and data centres; spare part kits are listed in levels (SPL1 to SPL4) so sites can hold the parts that match their service plan.Easy UPS On-Line (SRV): cost-focused double-conversion units, many with external battery pack support.
APC UPS in Oman and GCC conditions
Oman supplies 240 V single-phase and 415 V three-phase at 50 Hz, so international models with an I suffix (230 V nominal, adjustable to 240 V on most Smart-UPS units) are the usual choice. Heat is the main enemy: most APC UPS units are rated for operation up to 40 °C, while summer shade temperatures in Muscat and the interior pass 45 °C, and a lead-acid battery loses roughly half its service life for every 10 °C above 25 °C. Install UPS and batteries in a cooled room, keep filters clean in dusty inland sites, and size the standby generator with margin for UPS input and battery charging current.
All APC UPS systems, batteries and accessories on this site are grouped under UPS and Batteries, and the wider Schneider Electric range can be quoted together with them.

Facts checked against APC by Schneider Electric's published history, October 2026.

Browse APC products by category: UPS and Batteries.
Need a replacement battery for an APC UPS you already run? Use our APC UPS replacement battery finder to match the model to its official RBC cartridge.

FAQ

Questions about the APC SRTG192XLBP Smart-UPS RT 192V 5Ah Battery Pack

Answers from our engineering team on installation, compatibility and integration.

01What are the electrical ratings of the APC SRTG192XLBP?
The APC SRTG192XLBP is listed with a battery voltage of 192 V.
02What is supplied with the APC SRTG192XLBP?
APC lists these supplied items: installation guide.
03What are the dimensions and weight of the APC SRTG192XLBP?
The listed dimensions are 8.7 cm x 44 cm x 62 cm (H x W x D) and the weight is 39.4 kg.
04What operating conditions apply to the APC SRTG192XLBP?
Listed limits: operating temperature 0…40 °C; relative humidity 0…95 %.
05How can I request a quotation for the APC SRTG192XLBP?
Send the part number SRTG192XLBP with quantity and delivery location through the RFQ form. Seven Star LLC is an independent supplier in Muscat and replies with availability and a quotation.