Brand: JUMO
JUMO MIDAS S21 Ex Pressure Transmitter for Ex Areas
Description
Intrinsically safe pressure transmitter for zones 1 and 2
The JUMO MIDAS S21 Ex (type 404710) is a compact, welded-system pressure transmitter for gases, vapours and liquids in potentially explosive areas, with a two-wire 4 to 20 mA output. It carries intrinsic safety Ex ib marking for device group II zones 1 and 2 and group III zones 21 and 22, and it builds on the sensor technology of the MIDAS series.
JUMO lists oil, fuel and natural gas, paint shops and paint robots, process technology, plant engineering, testing and laboratory technology, and chemical plants as areas of application. Ranges run from 0.25 to 100 bar relative and from 0.6 to 25 bar absolute, and static and dynamic measurements are both supported.
Technical specifications
| Parameter | Specification |
|---|---|
| Data sheet type | 404710 |
| Sensor | Silicon sensor with stainless steel membrane; synthetic oil transfer medium |
| Ranges (relative) | 0 to 0.25 up to 0 to 100 bar; compound ranges down to -1 bar |
| Ranges (absolute) | 0 to 0.6 up to 0 to 25 bar |
| Output | 4 to 20 mA, two-wire |
| Supply | DC 16 to 28 V (DC 21 to 24 V with DNV approval); nominal DC 24 V; up to 23 mA |
| Process connections | G 1/4, G 3/8, G 1/2 (standard) DIN EN 837; 1/4-18 NPT, 1/2-14 NPT; G 1/4 and G 1/2 DIN 3852-11 |
| Ex marking as printed | ATEX II 2G Ex ib IIC T6…T4 Gb; II 2D Ex ib IIIC T70…T100 C Db; UKEX equivalents |
| Temperature classes | T4 up to +85 C; T5 up to +70 C; T6 up to +55 C ambient |
| Medium temperature | -40 to +85 C; storage -40 to +100 C |
| Protection | IP65 |
| Electrical connection | Attached cable, loose wires, M12 plug, line socket |
| Weight | About 170 g with G 1/2 connection |
| Certificates as printed | ATEX SEV 09 ATEX 0101 X; UKEX EPS 22 UKEX 1 088 X (extra code 085); DNV TAA0000211 (extra code 062); H2-ready KIWA P000415366HGV19 |
Choosing the version
Ex pressure transmitters are chosen by hazardous-area class first: confirm the zone, the gas or dust group and the temperature class against the Ex marking above, and match the ambient temperature to T4, T5 or T6. The supply must come from an intrinsically safe circuit, so an Ex-i repeater power supply or barrier is required; the supply range is narrower with the DNV extra code.
The order code builds from type 404710, the range (451 to 464 and 475 to 485 relative, 487 to 495 absolute, 998 and 999 special), output 405, process connection and electrical connection, and extra codes for the UKEX (085), DNV (062) and other options. Check which extra codes apply to M12 and line-socket versions.
Installation and use
Mount in any position; calibration is done upright with the process connection down. Because accuracy, long-term stability and overload are tabulated per range in the data sheet, select the range so the working pressure sits well inside the span. For viscous or crystallising media a standard seal-less measuring cell is not advisable; contact the manufacturer for a diaphragm seal solution.
The data sheet remarks that its application recommendations come from long experience but may not apply in every case.
Documents and quotation
Open the attached JUMO MIDAS S21 Ex data sheet 404710 (EN) for the complete data and dimension drawings. Before you place an order, confirm the Ex zone, temperature class and extra codes with the system designer, then submit your request with the exact code; our team prepares the quotation. Related items are listed under Pressure Instrumentation.
Datasheets & Documents
- Datasheet JUMO MIDAS S21 Ex data sheet 404710 (EN) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Temperature measurement is the origin of JUMO, founded in 1948 in Fulda, Germany, as a maker of glass thermometers. Today the catalog covers sensors and transmitters for temperature, pressure, level and liquid analysis, plus controllers and recorders. Seven Star LLC lists JUMO RTD probes, pressure and differential pressure transmitters, pH, conductivity, turbidity and dissolved oxygen instruments, and sources them for plants in Oman.
JUMO product families listed
JUMO uses family names that recur across the catalog:
- dTRANS: transmitters, including dTRANS T01 and T100 for temperature, dTRANS p02 DELTA for differential pressure, and dTRANS pH 02 and CR 02 for liquid analysis
- Wtrans: wireless probes and transmitters, such as Wtrans T for RTD temperature and Wtrans p for pressure
- digiLine and ecoLine: digital and optical analysis sensors, for example the digiLine O-DO S10 dissolved oxygen sensor and the ecoLine NTU turbidity sensor
- NESOS: float-based level transmitters and switches
- RTD temperature probes: screw-in types such as 902030 and mineral-insulated designs
Where JUMO sensors are used
JUMO sensors and transmitters are typical of food and beverage lines, water and wastewater treatment, pharmaceutical utilities, heating and cooling systems, and packaged machinery supplied to the GCC by European builders. Many requests are for a like-for-like replacement of a probe fitted by the machine maker, where length, thread and connector have to match exactly.
Ordering JUMO parts: what we need
JUMO identifies each product group by a six-digit type number, such as 902030, followed by an order code that fixes the options. The label of the delivered item normally carries a part number as well. Send whichever you have, ideally both, or a photo of the label. For JUMO temperature probes add insertion length, diameter, process connection, sensor type and wiring. For JUMO pressure sensors state range, output, process connection and electrical connector. For analysis sensors name the transmitter they connect to and the cable length.
Browse JUMO products by category: Temperature Instrumentation, Pressure Instrumentation, Liquid Analysis Sensors, Controllers & Data Acquisition, Level Transmitter.
Related products
Frequently Asked Questions
Its marking covers device group II for zones 1 and 2 and group III for zones 21 and 22, with Ex ib protection.
A two-wire 4 to 20 mA current output proportional to pressure.
The data sheet prints a DNV certificate (TAA0000211) for type 404710 with electrical connection 36 or 61 and extra code 062.
IP65.
The data sheet lists a KIWA H2-ready certificate for mobile hydrogen applications (CSA ANSI HGV 3.1:2022); confirm applicability to your version.

Reviews