- AC Drives
- Industrial Communications
- PLC & I/O Cards
- Vibration Monitoring
- Automation Accessories
- Controllers & Data Acquisition
- CCTV & Security
- Encoders
- Industrial Computers
- Safety Switches & Guard Locking
- HMI Displays
- Motor Soft Starters
- Isolator & Barrier
- Pneumatic Cylinders
- Servo Drives
- Automation Software
- Robotics
- Machine Vision
Brand: Hydac
Hydac ENS 3116-2-0205-400-K Electronic Level Switch
Description
Capacitive level monitoring with temperature sensing in one probe
The Hydac ENS 3116-2-0205-400-K (HYDAC part number 909234) is an electronic level switch for hydraulic tanks. A ceramic capacitive probe measures the fluid level, and a built-in semiconductor sensor measures the oil temperature, so a single instrument can raise a low-level alarm and an over-temperature alarm. It has a four-digit LED display and two PNP transistor switching outputs, each assignable to either level or temperature.
The probe in this code is 20.5 inches (about 520 mm) long with an active zone of 15.35 inches. It fits through a 22 mm collar to a G22L cutting ring coupling.
Technical specifications
| Parameter | Specification |
|---|---|
| HYDAC part number | 909234 |
| Model code | ENS 3116-2-0205-400-K |
| Sensor type | Capacitive fluid level sensor with ceramic probe |
| Physical probe length | 20.50 in |
| Active zone / measuring range | 15.35 in |
| Mechanical connection | 22 mm collar to fit cutting ring coupling G22L |
| Temperature sensor | Included; -13 to +212 °F, accuracy 3.0 °F, t90 up to 180 s |
| Switching outputs | 2 PNP transistor outputs, 1.2 A max. each; more than 100 million cycles |
| Repeatability / switching accuracy | 2 % FS / 2 % FS (calm fluid) |
| Max. speed of level change | 3.14 in/s |
| Fluids | Mineral hydraulic oils, synthetic oils, fluids containing water; others on request |
| Max. tank pressure | 7.25 psi (0.5 bar); short-term 43.5 psi |
| Display | 4-digit red LED, 7 mm digits |
| Supply voltage | 9 to 35 V DC without analogue output |
| Current consumption | 2.47 A total; 90 mA max. with inactive outputs |
| Electrical connection | Male M12x1, 4-pole |
| Operating and fluid temperature | 32 to 140 °F (0 to 60 °C) |
| Storage temperature | -40 to +176 °F |
| Protection class | IP 67 |
| Vibration / shock | 5 g / 25 g |
| Weight | Approx. 250 g for the 20.5 in probe (datasheet lists 180 to 300 g by length) |
| Approvals as printed | CE (EN 61000-6-1/2/3/4); cUL, certificate no. E318391 |
Settings and uses
Two menus hold the settings, with a programming lock against changes. The fluid type is chosen in the menu for oil or water, so the capacitive electronics calibrate to the medium. Switching points can use a switching-point function or a window function, with N/C or N/O direction and delays from 0.00 to 9999 seconds. A level offset function lets the zero be moved to a convenient tank reference. The display can show the actual level, the temperature, peak values or the switching points.
Code decoding
The datasheet pattern ENS 3 X 1 X – X – XXXX – 000 – K reads: the first digit after 3 chooses the temperature sensor (1 with, 2 without), 1 is the 22 mm collar, the following digit the plug (6 for four-pole M12x1), then the output model (2 is two switching outputs), the probe length 0205 (20.5 in), the 400 inch-based modification number and K for the ceramic probe. The USA datasheet gives dimensions in inches and the only tank pressure allowed is low, so this is for atmospheric-vented reservoirs only.
Check the tank depth against the 20.5 inch probe and keep the active zone clear of baffles and foam. Because water or oil is selected in the menu, recalibrate after changing the fluid grade.
Documents and quotation
The ENS 3000 datasheet (E 18.061.4) is attached. Please state the tank depth and the fluid. See also our level instrumentation range.
How the ENS 3116-2-0205-400-K works
The ceramic probe of the ENS 3116-2-0205-400-K forms part of a capacitor. As the fluid rises along the probe, the dielectric around it changes, and the measured capacitance changes with the immersed length. The electronics convert this capacitance into a level value in inches, show it on the LED display and compare it with the stored switching points. Because oil and water have very different dielectric properties, the fluid type is selected in the menu so that the evaluation matches the medium. The integrated semiconductor sensor measures the fluid temperature at the same time, which allows one instrument to monitor two important tank conditions.
There are no floats, reed contacts or moving parts, so there is nothing to stick in contaminated oil and nothing to wear. HYDAC states more than 100 million switching cycles for the transistor outputs.
Setting ranges for the 20.5 inch probe
| Function | Setting range |
|---|---|
| Measuring range (active zone) | 15.35 in |
| Level switching point | 0.25 to 15.35 in |
| Level hysteresis | 0.05 to 15.15 in |
| Level window: lower switch value | 0.25 to 15.05 in |
| Level window: upper switch value | 0.35 to 15.15 in |
| Level offset | 0 to 61.4 in |
| Level increment | 0.05 in |
| Temperature switching point | –9 to +212 °F, hysteresis 2 to 222 °F |
| Temperature window | lower –10 to 207 °F, upper –7 to 209 °F |
| Temperature increment | 1 °F |
| Switch-on / switch-off delay | 0.00 to 9999 s |
For the 20.5 inch probe, the dimension drawing shows an inactive zone of about 1.34 in at the lower end and about 2.56 in at the upper end, and a total length of about 24.01 in including the housing. Plan the switching points inside the active zone only.
Pin connection
The ENS 3X16-2 uses a male M12×1 4-pole plug: pin 1 +UB, pin 2 switching output SP2, pin 3 0 V, pin 4 switching output SP1. Each output can carry up to 1.2 A, and reverse-polarity, excess-voltage, override and short-circuit protection are built in.
ENS 3116-2-0205-400-K selection & ordering guide
- Temperature sensor: 1 = with (as on this model), 2 = without.
- Mechanical connection: 1 = 22 mm collar for a G22L cutting ring coupling.
- Electrical connection and output: 6-2 = M12×1 4-pole with 2 switching outputs; 6-3 = 1 switching output plus 1 analogue output; 8-5 = 5-pole with 2 switching outputs and 1 analogue output; P-8 = 8-pole with 4 switching outputs and 2 analogue outputs (only with temperature sensor).
- Probe length: 0100 = 9.80 in, 0162 = 16.2 in, 0205 = 20.5 in, 0287 = 28.7 in.
- 400 = standard in inch; K = ceramic probe.
If your control system needs a continuous level signal (4 to 20 mA or 0 to 10 V) instead of, or in addition to, the two switch contacts, choose an analogue output version, which needs an 18 to 35 V DC supply. With four switching outputs you can add warning levels in front of the minimum and maximum alarms, for example to warn of pump aeration before the low-level shutdown.
Installation & maintenance
- Install the probe vertically through the tank cover with the 22 mm collar and a G22L cutting ring coupling; connect the supplied M3 earth screw.
- The tank must be practically unpressurised: 7.25 psi maximum, 43.5 psi for less than one minute.
- Accuracy is specified for calm, non-turbulent fluid. Keep the probe away from the return-line outlet and from foam, or use a splash guard from the HYDAC accessories range.
- Respect the 32 to 140 °F fluid and operating temperature range.
- Clean the ceramic probe of sludge during tank service and check the level reading against a sight glass.
Typical applications in Oman & the GCC
The ENS 3000 is used primarily in hydraulics for level monitoring of tanks: hydraulic power units on presses and machine tools, lubrication units, mobile and offshore power packs, and test stands. Combining level and temperature monitoring in one penetration is useful on compact reservoirs where there is little room for separate instruments, and on plants in Oman and the GCC where high ambient temperatures make oil temperature supervision especially important.
Why source from Seven Star LLC
Seven Star LLC supplies HYDAC level switches and sensors across Oman and the GCC. Request a quote for the ENS 3116-2-0205-400-K, and tell us the tank depth, fluid and required outputs; our team can help confirm the correct ordering code.
Datasheets & Documents
- Datasheet Hydac ENS 3000 electronic level switch datasheet (E 18.061.4, USA edition) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Hydac is a German manufacturer of hydraulic components, filtration systems and sensors, founded in 1963 in Sulzbach/Saar, where the group is still headquartered. Hydraulic power units, lube oil systems, presses, turbines and mobile machines around the world run on Hydac accumulators, filters, coolers, valves and electronic switches.
Seven Star LLC is an independent supplier in Muscat. We list Hydac filter housings, bladder accumulators and electronic pressure and temperature switches for plants and workshops in Oman and the GCC, and source Hydac replacement elements and spare parts against the full model code.
Hydac product series
Filtration is the largest group on this site. It covers tank-top return line filters (RFM, RFN to DIN 24550), high-pressure inline filters (DF and DFF up to 420 bar, DFN, HFM, MDF and MFM), change-over filters for uninterrupted operation (DFDK, FMND), low-pressure and mobile filters (LF, LFF, MFX), spin-on filters (MF, MFD), suction filters (SF, SFM, SFF) and tank breather filters (BF, ELF). Each housing accepts elements in several filtration ratings and media, with optional visual or electrical clogging indicators.
Alongside the filters, Hydac makes SB330 bladder accumulators for energy storage and pulsation damping, and an electronics range that includes the EDS 3400 pressure switch with display, the ETS 1700 temperature switch with relay outputs, level and flow monitoring devices and hydraulic valves and components.
Where Hydac components are used
Typical installations are hydraulic power units on steel and process plants, gas and steam turbine lube and control oil systems, compressor and gearbox lubrication skids, injection moulding machines, presses and mobile hydraulics. In the Gulf region, filter elements and accumulator bladders are the most frequent maintenance items.
Ordering Hydac parts: what we need
- Filters and elements: housing type code, element code, filtration rating (micron) and media, seal material and clogging indicator type
- Accumulators: full model code, nominal volume, maximum pressure, bladder material and the pressure vessel approval required
- EDS and ETS switches: full type code including measuring range, output version and electrical connection
A clear photo of the nameplate or element label usually gives all of this.
Browse Hydac products by category: Filter Housings, Pressure Instrumentation, Temperature Instrumentation, Filtration Systems, Hydraulic Valves & Components.
Related products
Frequently Asked Questions
Fluid level with a capacitive ceramic probe and, in this version, fluid temperature as well.
20.5 inches physical length with a 15.35 inch active zone.
Two PNP transistor outputs, each assignable to level or temperature.
7.25 psi continuously and 43.5 psi short-term, so it is meant for vented tanks.
Mineral and synthetic hydraulic oils and fluids containing water; other fluids on request.

Reviews
There are no reviews yet.