Brand:

Mean Well LRS-150-48 Enclosed Switching Power Supply

Description

A low-profile 48 V enclosed supply for machine builders

The Mean Well LRS-150-48 is a 158.4 W enclosed-type switching power supply with a 48 V DC output at 3.3 A. The LRS-150 series is built in a metallic mesh case only 30 mm high, and the input is selected with a switch between 85 to 132 VAC and 170 to 264 VAC, so the unit is chosen for chassis and panel mounting rather than rail mounting.

Typical efficiency at 48 V is 90% and the series operates from -30 to +70 C with free-air convection. Mean Well lists a 5G vibration withstand and compliance with EN61558, EN50178, EN60664-1 and EN62477-1 for altitudes up to 2000 m. Protection covers short circuit, overload (hiccup mode), overvoltage and overtemperature.

Technical specifications

Parameter Specification
Manufacturer / series Mean Well, LRS-150
Model LRS-150-48
Output voltage / rated current 48 V DC / 3.3 A
Rated power 158.4 W
Voltage adjustment range 43.2 to 52.8 V
Ripple and noise (max.) 200 mVp-p
Voltage tolerance +/-1.0%
Line / load regulation +/-0.5% / +/-0.5%
Input voltage range 85 to 132 VAC / 170 to 264 VAC by switch; 240 to 370 VDC
Efficiency (typ.) 90%
AC current (typ.) 3 A at 115 VAC; 1.7 A at 230 VAC
Inrush current (typ.) Cold start 60 A at 230 VAC
Hold-up time (typ.) 40 ms at 230 VAC; 35 ms at 115 VAC
Overload protection 110 to 140%, hiccup mode, automatic recovery
Overvoltage protection 55.2 to 64.8 V, shut down; re-power to recover
Working temperature -30 to +70 C, with derating curve
Vibration 10 to 500 Hz, 5 G, 60 min per axis
Withstand voltage Input-output 4 kVAC; input-FG 2 kVAC; output-FG 1.25 kVAC
Safety approvals listed UL 62368-1, TUV EN 62368-1, EN 60335-1, EN 61558-1/-2-16
Dimensions (L x W x H) 159 x 97 x 30 mm
Weight 0.42 kg

Why a 48 V rail

A 48 V DC rail is common for telecom and network gear, PoE injectors, small servo and stepper drives, and battery-backed systems. At 3.3 A the LRS-150-48 offers about 158 W, and the output can be trimmed between 43.2 and 52.8 V when the load or cable drop needs it. If your application needs 12 V, 24 V or 36 V, the same series is offered in those voltages; check the model table in the datasheet.

Input switch, mounting and safety notes

Set the input selector to match the supply before power-up: the switch chooses between the 115 V and 230 V ranges, and a wrong setting at the higher voltage can damage the unit. The cold-start inrush is 60 A at 230 VAC, so allow for it in breaker selection. The datasheet recommends derating at low input voltage. As an enclosed supply it has screw terminals and is installed in a cabinet that provides touch protection; the final equipment must meet its own safety and EMC requirements. Fix the supply with the mounting holes on a flat metal plate or panel, and keep wiring away from the mesh openings to avoid damage to the connections.

Documents and quotation

The official manufacturer datasheet is linked in the Datasheet & Documentation section at the end of this page. A request for LRS-150-48 should state quantity, supply conditions, load current with peaks, operating temperature and required certificates, so that the right variant is confirmed. Alternatives are listed in Power Modules.

Reliability, EMC and environmental data for the Mean Well LRS-150-48

The values below are taken from the official Mean Well LRS-150 specification and complement the main table above.

Parameter Value (official datasheet)
Working humidity 20 – 90% RH non-condensing
Hold-up time (typ.) 40 ms at 230 VAC; 35 ms at 115 VAC
Leakage current <0.75 mA at 240 VAC
Switching frequency about 65 kHz
MTBF 2707.7K hours min. (Telcordia SR-332); 558.2K hours min. (MIL-HDBK-217F, 25°C)

How the LRS-150-48 works

The LRS-150-48 is an enclosed single-output supply. Its block diagram shows an EMI filter and rectifiers, a PWM power switching stage at about 65 kHz, and output rectifiers and filter that deliver the isolated 48 V rail. The control loop regulates the output and the protection circuits cover short circuit, overload and over-voltage. The supply is convection cooled with a low-profile 30 mm housing.

Selection & Ordering Guide

The LRS-150 series includes these output voltages:

  • LRS-150-12: 12 V DC, 12.5 A
  • LRS-150-15: 15 V DC, 10 A
  • LRS-150-24: 24 V DC, 6.5 A
  • LRS-150-36: 36 V DC, 4.3 A
  • LRS-150-48: 48 V DC, 3.3 A

Choose the LRS-150-48 for 48 V loads up to about 150 W, such as LED systems, telecom equipment or 48 V motors.

Installation & Maintenance

  • Isolate and lock out the supply circuit before wiring; installation should be carried out by a qualified electrician.
  • Use the conductor sizes, terminal data and protective earth connection shown in the official datasheet.
  • Respect the mounting orientation and clearances given by Mean Well so that the cooling of the LRS-150-48 works as designed.
  • After commissioning, measure the output voltage at the load and trim it only within the documented adjustment range.
  • During planned maintenance, check terminals for tightness and discolouration, remove dust, and confirm that the cabinet temperature stays inside the derating curve.

Typical Applications in Oman & the GCC

Typical uses in Oman and the GCC include LED signage and lighting, telecom and network equipment, industrial machines, vending and retail systems, and 48 V control equipment built into closed enclosures.

Why Source from Seven Star LLC

Seven Star LLC supplies Mean Well products, including the LRS-150-48, to panel builders, contractors and maintenance teams across Oman and the GCC. Send us the model code and quantity to request a quote, and our team can help confirm the correct ordering code, the right variant and any accessories for your project. When you are replacing an existing unit, share the nameplate data and we will compare it with the official LRS-150 documentation before you order.

Wiring and commissioning notes for the LRS-150-48

Before energising the LRS-150-48, confirm that the input wiring matches the terminal markings and that the protective earth is connected. Size the output cables for the full 3.3 A load plus a margin, and keep cable runs to the loads short to limit voltage drop on the 48 V rail. After start-up, measure the output voltage at the load terminals and trim it with the adjustment potentiometer if the cable drop requires it. Check the actual enclosure temperature at full load against the derating curve in the datasheet, which is important in hot plant rooms and outdoor cabinets in Oman and the GCC.

Datasheets & Documents
  • PDF Datasheet Mean Well LRS-150 series datasheet (EN) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Mean Well is a Taiwanese manufacturer of standard power supplies, founded in 1982 and headquartered in New Taipei City. Its catalogue covers thousands of standard models, from DIN rail and enclosed supplies to LED drivers, DC-DC converters and high-power units.

Seven Star LLC is an independent supplier in Muscat. We list Mean Well power supplies for control panels, automation equipment, lighting and electronics in Oman and the GCC.

Mean Well product series

DIN rail supplies include the MDR, DRA, EDR, NDR and SDR families, the ultra-slim XDR, the wide-input WDR and the three-phase TDR and XTR families, plus DDR DIN rail DC-DC converters. Enclosed supplies include the LRS, SE, SPV, MSP and HRPG families and the RST three-phase 5 kW unit. For lighting, the LPV constant voltage supply and the ELG LED driver are IP-rated for outdoor use.

The model code shows the family, the power and the output voltage: NDR-120-24, for example, is the NDR family, 120 W, 24 V output.

Where Mean Well power supplies are used

24 V control circuits in machine and process control panels, PLC and instrument supplies, telecom and security systems, LED lighting, battery charging and industrial electronics.

Ordering Mean Well power supplies: what we need

State the exact model code, the output voltage and current, the input range (single-phase, three-phase or DC), the mounting style, the cabinet or ambient temperature and any approvals required, so the correct variant can be quoted.

Frequently Asked Questions

What is the LRS-150-48 output?
48 V DC at 3.3 A, 158.4 W, adjustable from 43.2 to 52.8 V.
How is the input range selected?
A switch selects 85 to 132 VAC or 170 to 264 VAC.
How high is the case?
30 mm, with a 159 x 97 mm footprint.
What temperature range applies?
-30 to +70 C with derating.
How does it respond to overload?
Hiccup mode between 110 and 140% of rated power, recovering automatically.