Siglent SDL1020X 200 W 150 V 30 A DC Electronic Load
Description
SDL1020X is a single-channel Siglent programmable DC electronic load rated 150 V, 30 A and 200 W, with CC, CV, CR and CP modes, 0.1 mV / 0.1 mA readback resolution, a 3.5 inch colour display and built-in RS232, USB and LAN interfaces.
Load a power source the way the real application will
An electronic load sinks current from a supply under test. In constant-current mode the SDL1020X draws a fixed current regardless of terminal voltage, in constant-voltage mode it holds a fixed voltage, in constant-resistance mode it behaves like a fixed resistance (0.03 Ω to 10 kΩ) and in constant-power mode it dissipates a set wattage up to 200 W. Siglent lists power supplies, battery and handheld device design, industry, LED lighting and automotive electronics as target uses.
Dynamic mode switches between two levels (A and B) in continuous, pulsed or toggled fashion up to 25 kHz in CC mode and 12.5 kHz in CP mode, with an adjustable current rise time of 0.001 to 2.5 A/µs. A list function holds up to 100 steps and the program function 50 groups of steps for automatic pass/fail test sequences.
Key features as printed in the datasheet
- Battery discharge test with voltage, capacity or time stop conditions, up to 999 Ah and 24 hours.
- CR-LED mode with diode break-over voltage setting for LED driver testing.
- OCPT and OPPT modes for automatic over-current and over-power protection tests.
- 4-wire SENSE compensation and voltage rise/fall time measurement.
- External analog control with 0 to 10 V on EXT PRG; voltage and current monitoring outputs.
Technical specification
Input rating and modes (SDL1020X)
| Parameter | Specification |
|---|---|
| Input voltage | 0 to 150 V |
| Input current | 0 to 5 A and 0 to 30 A ranges |
| Input power | 200 W (0 to 40 °C) |
| Minimum operating voltage | 0.15 V at 5 A; 0.9 V at 30 A |
| CV mode | 0 to 36 V / 0 to 150 V; 1 mV; ±(0.05 % + 0.025 % FS) |
| CC mode | 0 to 5 A / 0 to 30 A; 1 mA; ±(0.05 % + 0.05 % FS) |
| CR mode | 0.03 Ω to 10 kΩ; 0.01 % + 0.0008 S (10 Ω to 10 kΩ) |
| CP mode | 200 W; 10 mW; ±(0.1 % + 0.1 % FS) |
Dynamic, readback and protection
| Parameter | Specification |
|---|---|
| Dynamic T1 / T2 | 20 µs to 999 s, 1 µs resolution |
| Current slew rate | 0.001 to 0.5 A/µs (5 A range); 0.001 to 2.5 A/µs (30 A range) |
| Minimum rise time | About 10 µs (5 A); about 12 µs (30 A) |
| Readback voltage | 0.1 mV (36 V range), 1 mV (150 V); ±(0.025 % + 0.025 % FS) |
| Readback current | 0.1 mA; ±(0.05 % + 0.05 % FS) |
| Readback power / resistance | 10 mW; ±(0.1 % + 0.1 % FS) / 0.001 Ω |
| Measuring speed | Voltage and current up to 500 kHz |
| Protections | OVP 41 V / 155 V; OCP 5.1 A / 31 A; OPP 210 W; OTP 85 °C; reverse voltage (LRV) |
| Battery measurement | 0.5 to 150 V input; capacity to 999 Ah; 1 s to 24 h |
| Input resistance | >200 kΩ |
Interface and mechanical
| Parameter | Specification |
|---|---|
| Display | 3.5 in. TFT-LCD |
| Interfaces | RS232, USB, LAN; USB-GPIB module optional |
| Software | PC software; SCPI and LabVIEW driver |
| Dimensions | 256 x 115 x 410 mm (W x H x D) |
| Weight | 5.8 kg |
| Conditions of specification | 25 ±5 °C after 30 minutes warm-up |
SDL1020X, SDL1020X-E and the 300 W models
The datasheet pairs each power class with an economy version. SDL1020X and SDL1020X-E are 150 V/30 A/200 W; SDL1030X and SDL1030X-E are 150 V/30 A/300 W. The base SDL1020X offers 0.1 mV / 0.1 mA measurement resolution and ±(0.05 percent + 0.05 percent FS) current accuracy, while the -E version has 1 mV / 1 mA readback resolution and ±(0.1 percent + 0.1 percent FS) current accuracy. Standard accessories are a USB cable, quick start guide, calibration certificate and power cord; a 30 A test lead (AWG 10, M6/M6, 1010 mm, 150 V) is optional.
Connection and safety notes
Use heavy-gauge leads such as the optional 30 A lead for high-current tests and connect the 4-wire sense leads at the device under test to remove lead voltage drop. Remember the 0.15 V and 0.9 V minimum operating voltages: below them the load cannot sink the full current. The load turns off and shows a prompt when OVP, OCP, OPP, OTP or reverse-voltage protection acts. Siglent specifies the unit for 0 to 40 °C input rating, so leave airflow around it.
Testing supplies, batteries and LED drivers
Power-supply repair benches use constant-current and dynamic modes to check regulation and transient response; battery rooms use the discharge function to measure capacity; solar and UPS service teams can load small DC sources and chargers. The 200 W, 150 V, 30 A envelope suits laboratory-scale equipment rather than large industrial banks. The datasheet gives no environmental or hazardous-area rating beyond the temperature figures.
Selection and installation notes
An electronic load is selected from the voltage, current and power of the source under test, and from the modes needed. Use leads rated for the full current with the shortest practical length, use remote sensing where the voltage drop matters, check the heat sink airflow and do not exceed the power rating at high voltage. Start tests at a low current and increase in steps, especially with batteries and supplies that have current limiting.
Information needed for a quotation
Send the full model code, the quantity, the delivery location in Oman or the GCC, the intended use and any accessories needed, so that the complete package can be quoted together.
Documents and supply information
The manufacturer data sheet is attached to this page and should be read together with the project specification and the site risk assessment before a purchase is confirmed. Ratings, standards and dimensions are quoted as printed on that sheet. Lead time, stock position and certificates available with the shipment are confirmed in the quotation, and we supply to Oman and the wider GCC region for industrial, utility and building services projects.
Related items
Siglent lists the 30 A test lead and USB-GPIB module for this series. Use it with a programmable supply such as the SPD3303X and a precision meter such as the SDM3055. See the Portable Test and Measurement category.
Frequently asked questions
What are the ratings of the SDL1020X?
150 V, 30 A and 200 W, with 0 to 5 A and 0 to 30 A current ranges.
Which load modes are available?
Constant current, constant voltage, constant resistance and constant power, plus dynamic, list, program, battery and CR-LED functions.
Can it test batteries?
Yes. The battery discharge function stops on voltage, capacity or time, with up to 999 Ah and 24 hours of measurement.
How is it connected to a computer?
By built-in RS232, USB and LAN interfaces, with SCPI commands and a LabVIEW driver.
Does Seven Star LLC act as a Siglent distributor?
No, we are an independent supplier in Muscat and supply Siglent items on request rather than acting as a Siglent channel partner.
Documents and quotation
Need SDL1020X? The Siglent datasheet is attached to this listing. Seven Star LLC (independent supplier, Muscat) can quote the item and arrange supply on request; list quantity and site location in your enquiry. Verify the code, dimensions and approvals in the document before ordering. Other products are in the category page.
Datasheets & Documents
- Datasheet Siglent SDL1000X datasheet (PDF) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Siglent Technologies is a Chinese maker of electronic test and measurement instruments, headquartered in Shenzhen with an R&D branch in Chengdu. Its founders began studying digital oscilloscopes in 2002, and in 2019 Siglent became the first general electronic test and measurement company listed on China's A-share market. Its products are sold in more than 80 countries and regions.
Seven Star LLC is an independent supplier in Muscat. We list Siglent instruments with the official datasheet beside each listing, for workshops, laboratories and training centres in Oman and the GCC.
Siglent company profile
| Origins | 2002, Shenzhen, China |
|---|---|
| Headquarters | Shenzhen, with R&D in Chengdu |
| Listing | Shanghai STAR Market (688112), since 2019 |
| Reach | More than 80 countries and regions |
| Product families | SDS1000X-E, SDS800X HD and SDS2000X Plus oscilloscopes, SDG arbitrary waveform generators, SSA spectrum analysers, SVA spectrum and vector analysers, power supplies, DC loads, multimeters |
Milestones
- 2002: Siglent's founders begin oscilloscope research.
- 2019: Siglent lists on China's A-share market.
- 2024: Siglent launches three 12-bit oscilloscope series.
Siglent product series
Oscilloscopes include the SDS1104X-E 100 MHz Super Phosphor oscilloscope, the SDS804X HD with 12-bit resolution and the SDS2204X Plus 200 MHz touchscreen oscilloscope. Spectrum instruments include the SSA3032X Plus 3.2 GHz spectrum analyzer with tracking generator and the SVA1015X spectrum and vector network analyzer.
Bench instruments include the SDG2042X arbitrary waveform generator, the SDM3055 5.5-digit multimeter, the SPD3303X three-channel linear power supply, the SPS5081X programmable switching power supply and the SDL1020X DC electronic load.
Where Siglent instruments are used
Electronics design, repair and production testing, RF and antenna work, education and training labs, and maintenance of control electronics in industrial plants.
Siglent products we list
Ordering Siglent instruments: what we need
Send the model, any bandwidth or software options, probes and accessories, supply voltage and whether a calibration certificate is required.
Facts checked against Siglent's own company profile and timeline (siglent.com), October 2026.
Browse Siglent products by category: Portable Test & Measurement.
Related products
Frequently Asked Questions
150 V, 30 A and 200 W, with 0 to 5 A and 0 to 30 A current ranges.
Constant current, constant voltage, constant resistance and constant power, plus dynamic, list, program, battery and CR-LED functions.
Yes. The battery discharge function stops on voltage, capacity or time, with up to 999 Ah and 24 hours of measurement.
By built-in RS232, USB and LAN interfaces, with SCPI commands and a LabVIEW driver.
No, we are an independent supplier in Muscat and supply Siglent items on request rather than acting as a Siglent channel partner.

Reviews