- Automation & ControlView all 2,667 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- HMI Displays
- Servo Drives
- Pneumatic Cylinders
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Parker
Parker P31EB92EGMBN5P Filter Regulator 1/4 in Poly Bowl
Description
P31EB92EGMBN5P miniature Global filter/regulator with 1/4 in port
The Parker P31EB92EGMBN5P is a miniature Global modular filter/regulator that combines a 5 micron particulate filter and a relieving pressure regulator in one body, with a 1/4 in NPT port, a polycarbonate bowl with a nylon bowl guard, a manual drain and an integral square gauge on the 125 psig scale. It belongs to the Global air preparation system that Parker builds in three body sizes, P31 miniature, P32 compact and P33 standard, and this part number sits in the P31 miniature size. Because the body is modular, the unit can be used on its own at a single drop point or joined to a lubricator and shut-off valve to form a full air-preparation train.
How the P31EB92EGMBN5P part number is built
| Position | Code | Meaning |
|---|---|---|
| Basic series | P31EB | Global modular mini filter/regulator |
| Thread type | 9 | NPT |
| Port size | 2 | 1/4 in |
| Element | E | 5 micron element |
| Bowl type | G | Polycarbonate bowl with a nylon bowl guard |
| Drain type | M | Manual drain |
| Relief | B | Relieving |
| Adjustment | N | Non-rising knob |
| Adjustment range / gauge | 5 | With square gauge, 125 psig scale (5 in the code) |
| Mounting | P | Plastic panel mount nut |
Reading the code this way lets you confirm that Parker P31EB92EGMBN5P is the 1/4 in poly-bowl, manual drain version before an order is placed, and it shows which letters to change if the site needs a different bowl, drain or thread.
Parker P31EB92EGMBN5P technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Parker / P31EB92EGMBN5P |
| Product type | Global modular filter/regulator, miniature size (P31 series) |
| Port size and thread | 1/4 in, NPT |
| Filter element | 5 micron polyethylene |
| Bowl type | Poly, with bowl guard |
| Drain option | Manual Drain |
| Regulator type | Relieving |
| Outlet pressure setting range | 0-125 psig (square gauge, code 5) |
| Pressure gauge | Square, integral |
| Maximum supply pressure | 10 bar (150 psig) for this bowl |
| Operating temperature range | -10 to 52 °C (14 to 125 °F) |
| Flow capacity at standard test condition | 15 dm³/s (32 scfm) |
| Test condition | 10 bar (145 psig) inlet, 6.3 bar (91.3 psig) set pressure and 1 bar (14.5 psig) pressure drop |
| Useful bowl retention | 12 cm³ (0.4 US oz) |
| Height (this drain type) | 176.9 mm (6.96 in) |
| Width and depth | 40 mm (1.58 in) wide, 61.3 mm (2.41 in) deep |
| Weight (series figure) | 0.19 kg (0.42 lb) |
| Body material | Aluminum |
The values above come from the Parker product page for P31EB92EGMBN5P and the Global air preparation catalog. Flow figures are catalog values measured at the stated test condition, so the delivered flow in a plant will move with inlet pressure, set pressure and the pressure drop you accept across the unit.
How the P31EB92EGMBN5P treats and controls compressed air
Air entering the Parker P31EB92EGMBN5P first passes the bowl section, where condensed water and heavy particles are separated from the stream and collect in the bowl, while the 5 micron element holds back fine solids. The catalog states the useful retention as 12 cm³ (0.4 US oz), which it defines as the volume below the quiet-zone baffle. Filtered air then reaches the regulator section, where a balanced poppet valve and a secondary aspiration path hold the outlet pressure steady as flow changes.
This is a relieving regulator, coded B in the part number. When the setting is turned down while the downstream line is dead-ended, excess pressure is vented through the regulator so the outlet falls to the new value. A non-relieving unit would keep the trapped pressure, which is why the relief letter is worth confirming for each machine. The integral gauge reads the regulated pressure, and the non-rising knob makes it easy to see and set the value without the knob climbing out of the body.
For this particular version, the polycarbonate bowl with a nylon bowl guard sets the pressure and temperature envelope. A plastic bowl is rated to 10 bar (150 psig) and -10 to 52 °C (14 to 125 °F), which suits most workshop and machine-side duties but calls for a position away from heat sources and direct sun. The guard around the bowl protects the polycarbonate from knocks.
Where P31EB92EGMBN5P fits in the Global range
Parker lists three families in this platform: P31 at 1/4 in, P32 at 1/4, 3/8 and 1/2 in, and P33 at 1/2 and 3/4 in. The P31EB base code used by P31EB92EGMBN5P stays inside its own size, so sibling part numbers such as P31EB92EGBBN5P, P31EB92EMMBN5P and P31EB92EMBBN5P share the same body and differ only in port, bowl, drain or gauge letters. Catalog flow capacity rises with body size and with port size, so check the demand before treating different sizes as interchangeable.
Modular bodies join with a bayonet latch, which means a lubricator, a second filter stage or a shut-off valve can be added later without re-piping the whole drop. Panel mounting is possible through the nut on the regulator neck where the code carries a P in the final position, and brackets and body connectors are sold as accessories.
Selection checklist before ordering P31EB92EGMBN5P
- Confirm the port: P31EB92EGMBN5P has a 1/4 in NPT connection, so check whether the line is NPT, BSPP or BSPT before choosing the thread digit.
- Check the flow: the catalog gives 15 dm³/s (32 scfm) for this port at the stated test condition.
- Match the bowl to the duty: the polycarbonate bowl with a nylon bowl guard is rated to 10 bar (150 psig) and -10 to 52 °C (14 to 125 °F).
- Decide on the drain: this version has a manual drain, selected by the letter M in the code, and other drain letters are listed in the options chart.
- Verify the outlet range: the 125 psig gauge scale in this code must cover the highest working pressure the machine needs.
- Confirm that a relieving regulator is acceptable for the downstream equipment.
- Make sure the air is within the maximum supply pressure of the bowl, including pressure spikes from the compressor.
Installing, commissioning and maintaining P31EB92EGMBN5P
Mount the P31EB92EGMBN5P vertically with the bowl hanging down, and follow the flow arrow on the body; the head needs free space below it for bowl removal, and the catalog dimension for this version is 176.9 mm (6.96 in) in height with 40 mm (1.58 in) wide, 61.3 mm (2.41 in) deep. Install an isolating valve upstream, make up the thread with a suitable sealant, and avoid over-torquing the aluminum body. Raise the pressure to the target from below rather than turning down from a higher value, because the catalog recommends setting regulated pressure by increasing it to the desired point.
This version has a manual drain, so draining belongs on the routine round sheet; in humid coastal plants the bowl may need emptying more than once per shift. Replace the 5 micron element when pressure drop rises or on the site schedule, and never wash a polycarbonate bowl with solvents.
The catalog lists service parts for this size, including bowl kits P31KB00BGM (plastic bowl with guard, manual drain), P31KB00BGB (plastic bowl with guard, pulse drain) and P31KB00BMB (metal bowl, pulse drain). Keeping one element and one bowl kit on the shelf shortens any outage on a critical line.
Typical applications in Oman and the GCC
The mini filter/regulator is meant for small pneumatic circuits, such as a single cylinder, a gripper or a miniature valve island, where only a modest flow is needed and cabinet space is tight. In Oman and the wider GCC the working conditions are demanding: high ambient temperature, dusty air around construction, oil and gas, power and desalination sites, and humid coastal air that produces plenty of condensate. In such places the poly, with bowl guard bowl and manual drain of P31EB92EGMBN5P should be matched to the temperature at the installation point, and the catalog limit of -10 to 52 °C (14 to 125 °F) for this bowl is a useful reference when a unit sits near hot piping or in direct sun.
Typical users include maintenance teams on process skids, OEM builders of packaging and handling lines, workshop air systems and utility plants. Compressed air quality in the region is often limited by receiver and dryer condition, so a point-of-use filter such as this one remains the last defense before sensitive pneumatic parts.
P31EB family variants and related part numbers
| Part number | Port (NPT) | Variant | Flow, dm³/s (scfm) |
|---|---|---|---|
| P31EB92EGMBN5P (this page) | 1/4 in | 8 bar (125 psig) relieving – poly bowl – manual drain | 15 (32) |
| P31EB92EGBBN5P | 1/4 in | 8 bar (125 psig) relieving – poly bowl – pulse drain | 15 (32) |
| P31EB92EMMBN5P | 1/4 in | 8 bar (125 psig) relieving – metal bowl – manual drain 15 (32) | 17 (250) |
| P31EB92EMBBN5P | 1/4 in | 8 bar (125 psig) relieving – metal bowl – pulse drain | 15 (32) |
The table lists catalog quick-selection part numbers with NPT ports. Letters in the code allow BSPP or BSPT threads, other bowls and different gauge ranges, so a version not shown can often be specified by changing the corresponding position of P31EB92EGMBN5P.
Information to send with an RFQ for P31EB92EGMBN5P
- Full part number and quantity.
- Line size and thread type (NPT, BSPP or BSPT) of the existing piping.
- Working pressure, maximum compressor pressure and required flow.
- Ambient temperature at the installation point and whether the location is indoors or outdoors.
- Preferred bowl, drain and gauge arrangement, and any need for brackets or spare element and bowl kits.
- Delivery location in Oman or the GCC and required date.
Documents and quotation
The official Parker Pneumatic Division catalog 0750-3 US for the Global Air Preparation System (P31, P32 and P33 series, English) is attached on this page as a PDF and lists the Parker P31EB92EGMBN5P by its order code. It covers the flow curves, the pressure ranges, the bowl, drain and filter element options, the modular connection kits, the dimensions and the full order-code key for filters, regulators and filter-regulators. Check the port size, the bowl type, the drain and the pressure range against your air system, then send us the quantity and the delivery location for a quotation.
Seven Star LLC supplies Parker pneumatic products in Oman and the GCC, so quotation requests with the details above can be sent for P31EB92EGMBN5P and related Global air preparation parts.
Datasheets & Documents
- Datasheet Parker Global Air Preparation System Catalog 0750-3 US (PDF) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Parker Hannifin is an American manufacturer of motion and control technologies, founded in 1917 in Cleveland, Ohio, by Arthur L. Parker as the Parker Appliance Company. Its first product was a pneumatic brake system for trucks and buses. In 1957 the company bought Hannifin, a maker of hydraulic and pneumatic cylinders and valves, and took the Parker Hannifin name. It is headquartered in the Cleveland area and listed on the New York Stock Exchange.
Seven Star LLC supplies the Parker items that maintenance teams request most: Lucifer solenoid valves, including NAMUR types for actuated valves, along with filter elements and hydraulic gear pumps.
Parker company profile
| Founded | 1917, Cleveland, Ohio, USA, by Arthur L. Parker |
|---|---|
| Headquarters | Cleveland area, Ohio, USA |
| Ownership | Public company, New York Stock Exchange (PH), listed since 1964 |
| First product | Pneumatic brake system for trucks and buses |
| Product families | Hydraulic pumps, cylinders and valves, pneumatic valves and FRLs, instrumentation fittings and valves, hoses and couplings, filtration (including Racor and Velcon), seals and O-rings |
Milestones
- 1917: Arthur L. Parker starts the Parker Appliance Company in Cleveland.
- 1924: Parker restarts the business after a 1919 accident destroyed its inventory.
- 1957: Parker acquires Hannifin and becomes Parker Hannifin.
- 1964: The shares are listed on the New York Stock Exchange.
Parker product lines listed here
Most of the listing is Lucifer, the Parker solenoid valve line that many nameplates still show as a brand in its own right. The 341N types (341N01, 341N22, 341N31) are NAMUR-interface valves that bolt straight onto a pneumatic actuator to pilot it. The E131K03 is a direct-acting 3/2 valve, and the 322K4706 and 7341NAKBHNM0 are further Lucifer solenoid valves. Parker sells Lucifer valve bodies and their coils or electrical parts as separate items, so one body can be combined with different voltages and enclosure types.
Other Parker lines appear: a hydraulic gear pump (P51A478BEY25-07-ZY), a coalescing filter element (9000040001) and a Triple-Lok 37-degree flare tube fitting.
Where Parker components are used
Lucifer NAMUR valves sit on quarter-turn actuators for on-off and shutdown valves in oil and gas, power and water plants across the GCC. Line-mounted solenoid valves switch instrument air, water, steam and light oils on skids and machines. Gear pumps drive hydraulic power units and mobile equipment, and coalescing elements protect instrument air and gas sampling systems from oil and water aerosols.
Parker products we list
Ordering Parker parts: what we need
Parker part numbers are long and every character counts. Please send:
- Solenoid valves: valve number from the body, coil or electrical part number, voltage and frequency, and the Ex marking if the coil is certified
- Gear pumps: the complete code from the nameplate, including the assembly number, which fixes displacement, shaft, ports and rotation
- Filter elements: element number and the housing model it fits
A photo of the nameplate is welcome. We check the code against Parker documentation and identify the manufacturer's current equivalent if a number has been superseded.
Facts checked against Parker's centennial timeline and the Encyclopedia of Cleveland History, October 2026.
Browse Parker products by category: Solenoid Valve, Filtration Elements, Pumps.
FAQ
Questions about the Parker P31EB92EGMBN5P Filter Regulator 1/4 in Poly
Answers from our engineering team on installation, compatibility and integration.
01What does the part number P31EB92EGMBN5P tell me?
It identifies the P31 mini filter/regulator with a 1/4 in NPT port, a polycarbonate bowl with a nylon bowl guard and a manual drain. Each letter and digit follows the Parker ordering code for the P31EB base series, so the version can be checked before ordering.
02What flow can the P31EB92EGMBN5P pass?
The catalog gives 15 dm³/s (32 scfm) for the 1/4 in port, measured at 10 bar (145 psig) inlet, 6.3 bar (91.3 psig) set pressure and 1 bar (14.5 psig) pressure drop. Real flow in a plant depends on inlet pressure, set pressure and the pressure drop that the system accepts.
03What pressure and temperature limits apply to P31EB92EGMBN5P?
With this bowl the maximum supply pressure is 10 bar (150 psig) and the operating temperature range is -10 to 52 °C (14 to 125 °F). Do not exceed these limits, including pressure peaks from the compressor.
04Is the P31EB92EGMBN5P a relieving regulator?
Yes, the letter B in the code selects a relieving regulator. When the setting is reduced against a closed downstream line, the excess pressure vents through the regulator, and the outlet drops to the new value.
05How should the outlet pressure of P31EB92EGMBN5P be set?
Parker recommends setting regulated pressure by increasing it up to the desired value rather than lowering it from a higher one. The integral gauge in this code reads the regulated pressure on the 125 psig scale.


















Reviews
There are no reviews yet.