Parker Racor 500FG10 500FG Fuel Filter Water Separator
Description
500FG10 Racor 500FG diesel fuel filter water separator, 10 micron
The Parker Racor 500FG10 is a single turbine fuel filter and water separator assembly for diesel engines. It belongs to the Racor Turbine Series 500FG, a compact housing with a clear plastic bowl, a brass T-handle on the lid and mounting brackets cast into the housing. The Parker Racor 500FG10 is supplied with a 10 micron element, and it connects with 3/4"-16 UNF (SAE J1926) ports.
Seven Star LLC supplies Parker Racor 500FG10 in Oman and the GCC. This page explains the part number, lists the data published by Parker in the 500FG data sheet and on the Parker product page, and covers selection, installation, servicing and the matching parts. The 10 micron grade is the middle choice of the three element grades in the 500FG data sheet. It suits engines and day tanks where the fuel is reasonably clean but a finer cut than 30 micron is wanted ahead of the injection equipment.
How to read the part number 500FG10
The Parker 500FG data sheet includes a part number builder. The number starts with the turbine model, then an optional heater voltage and then the filtration rating. For 500FG10 the elements are:
| Element | Meaning for 500FG10 |
|---|---|
| 500FG | Turbine model: 500FG single turbine assembly, rated 60 gph (227 lph) |
| 12 / 24 (heater option) | Absent for 500FG10, so the assembly has no heater (12 = 12 VDC and 24 = 24 VDC heater options exist in the range) |
| 10 (filtration rating) | 10 = 10 micron element (the range offers 2, 10 and 30 micron) |
The data sheet lists the following assemblies for this housing: 500FG2 is the 500 Turbine Assy., 2 micron; 500FG10 is the 500 Turbine Assy., 10 micron; 500FG30 is the 500 Turbine Assy., 30 micron; 500FG1230 is the 500 Turbine Assy., 12 VDC heater, 30 micron; 500FG242 is the 500 Turbine Assy., 24 VDC heater, 2 micron; 500FG2430 is the 500 Turbine Assy., 24 VDC heater, 30 micron.
Parker Racor 500FG10 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Parker Racor / 500FG10 |
| Product type | 500FG filter housing, 500 single turbine assembly |
| Application | Diesel fuel, mobile filtration |
| Filtration rating | 98% at 10 micron |
| Heater | Not included |
| Maximum flow rate | 60 gph (227 lph) |
| Connection | 3/4"-16 UNF-2B SAE female (SAE J1926) |
| Bowl | Clear engineering plastic |
| Height | 11.45 in (29.08 cm) |
| Width | 4.15 in (10.5 cm); 6.5 in (16.51 cm) with bracket |
| Depth | 4.15 in (10.5 cm); 5.17 in (13.13 cm) with bracket |
| Dry weight | 4.0 lb (1.8 kg) |
| Service clearance (top) | 4.0 in (10.16 cm) |
| Maximum head pressure | 15 psi (1.03 bar) |
| Installation | Vacuum (suction side) installation recommended |
| Replacement element | 2010TM-OR (includes element seal parts) |
| Data sheet | RSL0288 Turbine Series 500FG |
The figures above come from the Parker data sheet RSL0288 (revision of March 2025) and from the Parker product page for the 500FG10. The product page lists the application as mobile filtration and the valve type as none. Treat the dimensions as nominal and leave the clearances shown in the data sheet when you plan the mounting location.
How the 500FG10 works
A turbine series housing combines a centrifuge stage and a filter element in one unit. The data sheet lists a centrifuge and baffle kit, a checkball and gasket kit and a self-venting drain kit as service parts, which reflects the internal layout: fuel enters the housing, passes the turbine centrifuge and baffle where water and heavier contaminants are thrown out, and then flows through the replaceable 10 micron element before leaving to the engine. Water and sediment collect in the clear bowl below, where they can be seen and drained.
The 500FG10 is rated at 98 percent at 10 micron on the Parker product page, and the maximum flow rate is 60 gph (227 lph). The label on the housing shown on the Parker product image gives a maximum working vacuum of 28.5 in. Hg and a test pressure of 30 psig, which is why the data sheet recommends installing the assembly on the suction side of the fuel pump, with a maximum head pressure of 15 psi (1.03 bar).
The 500FG10 has no heater. If you need heating on the same 500FG housing, the 12 VDC and 24 VDC heated versions are listed in the data sheet (for example 500FG1230 and 500FG2430 with 30 micron elements, 500FG242 with a 2 micron element).
Where the 500FG10 fits in the fuel system
The 500FG10 sits between the fuel tank and the engine fuel pump as a primary filter. Related assemblies in the same 500FG housing are 500FG2, 500FG30, 500FG1230, 500FG242, 500FG2430. The 10 element is 2010TM-OR, and each element comes with the T-handle O-ring and lid gasket it needs.
Spare parts for the housing in the data sheet include the T-handle kit RK23183, the 500FG lid kit RK 15078, the bowl kit RK15405 (2002 to present, with a 5/8"-11 drain port), the checkball and gasket kit RK 15010B, the centrifuge and baffle kit RK 15013D, the bowl plug kit RK 20126, the bowl fasteners RK 15081 and the complete seal service kit RK 15211. A water-in-fuel probe (RK33802) and a water detection module kit (RK 11-1570) are available for installations that need a warning light.
Selection checklist for the 500FG10
- Pick the 10 micron grade when the engine builder or injector supplier asks for a finer filtration level than the coarse 30 micron grade, and the fuel supply is clean enough that the element will not block quickly. Pick 2 micron (500FG2) only when the engine data demands it, because a finer element loads faster.
- Check the connection: the ports are 3/4"-16 UNF SAE female, so confirm the hose or tube adapters on the engine before ordering.
- Check the flow: the housing is rated at 60 gph (227 lph), so confirm the engine fuel consumption plus return flow stays below that figure.
- Check the space: the housing is 11.45 in high and needs 4.0 in clearance above for element change.
- Install the assembly on the vacuum (suction) side of the fuel pump, as the data sheet recommends.
- Decide on options: a heater, a water-in-fuel probe or a vacuum gauge kit (RK19671 for assemblies made after 2002) can be added by kit.
Installation, commissioning and maintenance of the 500FG10
- Mount the housing upright with the bracket on a rigid support, with 4.0 in free above the lid.
- Connect the inlet and outlet to the 3/4"-16 UNF ports with the correct adapters and hoses rated for diesel.
- Fill the housing with clean fuel as described in the Parker installation instructions for the 500 series, then prime and vent the system.
- Check for leaks at the lid, the bowl ring and the ports, and for air leaks on the suction side.
- Watch the clear bowl: drain the collected water before it reaches the element, and replace the 2010TM-OR element when the vacuum gauge or engine performance shows restriction.
- Replace the T-handle O-ring, lid gasket and bowl gasket with the element, using the T-handle and seal kits listed in the data sheet.
Keep at least one spare 2010TM-OR element and a seal service kit for each filter. In hot climates fuel in bowls warms quickly, so check the bowl and the plastic parts during routine inspections.
Typical applications in Oman and the GCC
Diesel engines are used across Oman and the GCC for standby and prime power, water supply and pumping, construction plant and workshop equipment. High ambient temperature speeds up water condensation and microbial growth in stored fuel, and dust gets into tanks during refuelling, so a clear-bowl separator that makes water visible is a practical protection. In Oman and the GCC the 500FG10 is a good match for standby generator sets, pumps and compressors driven by small diesel engines, where fuel is stored in tanks for long periods and a fine cut protects the injection equipment from sediment and water that collect in hot conditions.
The 500FG assembly family compared with the 500FG10
| Assembly | Description (Parker data sheet RSL0288) |
|---|---|
| 500FG2 | 500 Turbine Assy., 2 micron |
| 500FG10 | 500 Turbine Assy., 10 micron |
| 500FG30 | 500 Turbine Assy., 30 micron |
| 500FG1230 | 500 Turbine Assy., 12 VDC heater, 30 micron |
| 500FG242 | 500 Turbine Assy., 24 VDC heater, 2 micron |
| 500FG2430 | 500 Turbine Assy., 24 VDC heater, 30 micron |
All six assemblies use the same 500FG housing and ports, so the choice comes down to filtration rating and heater voltage. The element parts for the family are 2010SM-OR (2 micron), 2010TM-OR (10 micron) and 2010PM-OR (30 micron).
Information to send with an RFQ for 500FG10
- Part number 500FG10 and the quantity required.
- Engine make, model and fuel consumption, to check against the 60 gph rating.
- Supply voltage if a heater is wanted (12 or 24 VDC).
- Port adapters or hoses needed for the 3/4"-16 UNF connections.
- Spare elements (2010TM-OR), seal kits and bowl kits, and the delivery location in Oman or the GCC.
Documents and quotation
The Parker data sheet RSL0288 for the 500FG turbine series is attached on this page. It contains the dimensions, the part number builder and the spare parts list for the 500FG10.
Seven Star LLC supplies 500FG10 in Oman and the GCC, with elements and service kits. Send your RFQ with the details above and we will confirm availability and delivery.
Datasheets & Documents
- Datasheet Parker Racor 500FG10 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Parker Hannifin is an American manufacturer of motion and control technologies, founded in 1917 in Cleveland, Ohio, by Arthur L. Parker as the Parker Appliance Company. Its first product was a pneumatic brake system for trucks and buses. In 1957 the company bought Hannifin, a maker of hydraulic and pneumatic cylinders and valves, and took the Parker Hannifin name. It is headquartered in the Cleveland area and listed on the New York Stock Exchange.
Seven Star LLC supplies the Parker items that maintenance teams request most: Lucifer solenoid valves, including NAMUR types for actuated valves, along with filter elements and hydraulic gear pumps.
Parker company profile
| Founded | 1917, Cleveland, Ohio, USA, by Arthur L. Parker |
|---|---|
| Headquarters | Cleveland area, Ohio, USA |
| Ownership | Public company, New York Stock Exchange (PH), listed since 1964 |
| First product | Pneumatic brake system for trucks and buses |
| Product families | Hydraulic pumps, cylinders and valves, pneumatic valves and FRLs, instrumentation fittings and valves, hoses and couplings, filtration (including Racor and Velcon), seals and O-rings |
Milestones
- 1917: Arthur L. Parker starts the Parker Appliance Company in Cleveland.
- 1924: Parker restarts the business after a 1919 accident destroyed its inventory.
- 1957: Parker acquires Hannifin and becomes Parker Hannifin.
- 1964: The shares are listed on the New York Stock Exchange.
Parker product lines listed here
Most of the listing is Lucifer, the Parker solenoid valve line that many nameplates still show as a brand in its own right. The 341N types (341N01, 341N22, 341N31) are NAMUR-interface valves that bolt straight onto a pneumatic actuator to pilot it. The E131K03 is a direct-acting 3/2 valve, and the 322K4706 and 7341NAKBHNM0 are further Lucifer solenoid valves. Parker sells Lucifer valve bodies and their coils or electrical parts as separate items, so one body can be combined with different voltages and enclosure types.
Other Parker lines appear: a hydraulic gear pump (P51A478BEY25-07-ZY), a coalescing filter element (9000040001) and a Triple-Lok 37-degree flare tube fitting.
Where Parker components are used
Lucifer NAMUR valves sit on quarter-turn actuators for on-off and shutdown valves in oil and gas, power and water plants across the GCC. Line-mounted solenoid valves switch instrument air, water, steam and light oils on skids and machines. Gear pumps drive hydraulic power units and mobile equipment, and coalescing elements protect instrument air and gas sampling systems from oil and water aerosols.
Parker products we list
Ordering Parker parts: what we need
Parker part numbers are long and every character counts. Please send:
- Solenoid valves: valve number from the body, coil or electrical part number, voltage and frequency, and the Ex marking if the coil is certified
- Gear pumps: the complete code from the nameplate, including the assembly number, which fixes displacement, shaft, ports and rotation
- Filter elements: element number and the housing model it fits
A photo of the nameplate is welcome. We check the code against Parker documentation and identify the manufacturer's current equivalent if a number has been superseded.
Facts checked against Parker's centennial timeline and the Encyclopedia of Cleveland History, October 2026.
Browse Parker products by category: Solenoid Valve, Filtration Elements, Pumps.
FAQ
Questions about the Parker Racor 500FG10 500FG Fuel Filter Water
Answers from our engineering team on installation, compatibility and integration.
01What flow rate can the 500FG10 handle?
The Parker data sheet gives a maximum flow rate of 60 gph (227 lph) for the 500FG housing. Check the fuel consumption of the engine plus any return flow against this figure before installing the 500FG10.
02What filtration rating does the 500FG10 have?
The Parker product page lists 98 percent at 10 micron for the 500FG10. The 500FG range also offers 2 micron and 10 or 30 micron elements in the other part numbers.
03Does the 500FG10 have a heater?
No, the 500FG10 is the unheated version. Heated versions of the same housing exist with 12 VDC or 24 VDC heaters, for example 500FG1230 and 500FG2430.
04Which element fits the 500FG10?
The replacement element for the 500FG10 is 2010TM-OR, a 10 micron element. Parker states that it includes the T-handle O-ring and lid gasket needed for the change.
05Where should the 500FG10 be installed in the fuel line?
The data sheet recommends vacuum installation, which means on the suction side of the fuel pump. The maximum head pressure is 15 psi (1.03 bar), and the housing needs 4.0 in clearance above the lid to change the element.