- Automation & ControlView all 3,188 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Encoders
- Motor Soft Starters
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Victaulic
Victaulic Style 927 FireLock Mechanical-T Branch Outlet
Description
Overview
Victaulic Style 927 is the FireLock Mechanical-T bolted branch outlet. It gives a direct branch connection wherever a hole can be cut in a carbon steel pipe, in run by branch sizes from 2 x 1 inch to 8 x 4 inch (DN50 x DN25 to DN200 x DN100), at up to 363 psi (2503 kPa, 25 bar). The branch can be a female threaded outlet or, on the larger combinations, a grooved outlet, and a cross version, Style 927 Cross, puts a branch on both sides of the run. The manufacturer designs it for fire protection systems only. Seven Star LLC is an independent supplier serving Oman and the GCC.
The housing is ductile iron to ASTM A536 grade 65-45-12, finished in red as standard or hot dip galvanized as an option. Two zinc plated track bolts with hex flange nuts pull the saddle onto the pipe, compressing a gasket that surrounds the cut hole.
How Victaulic Style 927 is used in a fire water layout
A mechanical tee replaces a welded or fabricated tee. The fitter cuts a hole with a hole saw, seats the gasket, clamps the housing and has a branch. That makes the outlet useful for adding a branch to an existing main during an extension, for dropping a riser from a ring main, and for inserting a hose valve or flow switch position at a spot not planned in the original design.
Technical data
| Parameter | Value |
|---|---|
| Product | FireLock Mechanical-T bolted branch outlet, Style 927 and 927 Cross |
| Run x branch sizes | 2 x 1 inch to 8 x 4 inch, DN50 x DN25 to DN200 x DN100 |
| Maximum working pressure | 363 psi / 2503 kPa / 25 bar |
| Pipe material | Carbon steel |
| Service | Fire protection systems only |
| Housing | Ductile iron ASTM A536 grade 65-45-12 |
| Coating | Red as standard; hot dip galvanized optional |
| Gasket, 2 x 1 to 2 x 1 1/2 inch | Grade E EPDM, green; wet and oil free dry sprinkler service; FM approved; ambient temperature only |
| Gasket, 2 1/2 x 3/4 to 8 x 4 inch | Grade E EPDM Type EC, green and violet stripes; same service limits |
| Bolts and nuts | Zinc plated carbon steel track bolts ASTM A449 or ISO 898-1 Class 9.8, flange nuts ASTM A563 Grade B; hot dip galvanized optional |
| Publication | 10.55 |
Hole size and dimensions
| Run x branch | Hole saw and housing dimensions |
|---|---|
| 2 x 1 inch (DN50 x DN25) | Required hole 1 1/2 in, maximum 1 5/8 in; V 1.65 in, W 1.56 in, Y 5.43 in, Z 2.88 in; about 1.13 lb |
| 2 x 1 1/2 inch | Hole 1 3/4 in, max 1 7/8 in; V 1.81 in; Y 5.43 in; Z 3.13 in |
| 2 1/2 x 1 inch (DN65 x DN25) | Hole 1 1/2 in, max 1 5/8 in; V 1.87 in, W 1.82 in, Y 5.83 in, Z 3.03 in |
| 3 x 1 1/2 inch (DN80 x DN40) | Hole 2 in, max 2 1/8 in; V 2.15 in, W 2.13 in, Y 6.39 in, Z 3.35 in |
| 3 x 2 inch (DN80 x DN50) | Hole 2 1/2 in, max 2 5/8 in; V 2.08 in, W 2.13 in, Y 6.39 in, Z 4.09 in threaded outlet |
The hole must be within the stated limits, so use the right saw. A hole that is too small chokes the branch, and a hole that is too large leaves the gasket unsupported at the edge.
How Victaulic Style 927 differs from Style 922 and Style 912
The two smaller outlets stop at 2 1/2 inch runs and carry threaded outlets only: Style 922 up to 300 psi, Style 912 to 232 psi. Style 927 reaches runs of 8 inch with branches of 4 inch, offers grooved branches, and its 363 psi rating is higher. Its Type EC gasket on 2 1/2 x 3/4 inch and larger is a green and violet striped EPDM, whereas the two smallest sizes use a plain green Grade E gasket. All of these are for ambient temperature fire sprinkler service and not for hot water or steam.
Typical applications in Oman and the GCC
Cross mains in logistics warehouses, hangar sprinkler grids, tank farm fire water rings, and hotel risers all need branch points. Where a project is built in phases, a mechanical tee allows the next phase to be tied in without shutting down and welding. In industrial plants, the tee is a handy way to add a hydrant spur or foam inlet.
Planning branches on a fire water main
Branch outlets deserve some planning because each hole weakens the pipe locally and each outlet adds a possible leak path. Keep outlet positions clear of weld seams and of couplings, leave enough distance between adjacent holes that the housings do not overlap, and orient the outlet so that the bolts remain reachable with a spanner or impact wrench after the pipe is hung. Think about hydraulics too: a branch of 4 inch on an 8 inch run takes a large share of flow, and the friction loss through the outlet should be taken from the manufacturer data, not guessed. On vertical risers, mark the hole position on the high side of the pipe if the outlet will feed an air vent. When specifying for hot, sun exposed plant yards in the Gulf, consider the galvanized housing and bolts so the assembly stays serviceable for the life of the system.
Installation and maintenance
Depressurize and drain the pipe. Mark and cut the hole, deburr it and clean the pipe surface around it. Check publication I-100 for gasket lubrication. Seat the gasket, position the housing, and tighten the nuts evenly. Check that the threaded or grooved outlet points where the layout drawing says. During maintenance, look for weeping, rust at the bolts and distortion around the hole, and replace the gasket whenever the outlet is removed.
Selection and compatibility
Pick the run and branch combination from the dimensions list, confirm that the pipe is carbon steel, and verify that the service is wet or oil free dry fire protection. Confirm the coating requirement, and ask for galvanized bolts if the housing is galvanized. If the service is anything other than ambient temperature fire water, do not use this outlet.
Ordering notes
For Victaulic Style 927, specify run size, branch size, branch type (threaded or grooved), single or cross, coating and quantity.
Related items you may also need: Victaulic Style 177N QuickVic Flexible Coupling DN50-DN200 | Victaulic Style 107N QuickVic Rigid Coupling | Victaulic Series 761 Vic-300 MasterSeal Butterfly Valve | All Victaulic products.
Documents and quotation
The manufacturer publication 10.55 is attached with the full size list. To obtain a quotation for Victaulic Style 927, send the combinations, quantity and delivery location in your RFQ and we will confirm supply to Oman and the GCC.
Other Models in the Victaulic Outlet Range
Seven Star LLC supplies models from the Victaulic Outlet range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Victaulic Style 922 FireLock Outlet-T Branch Outlet | Pipes & Fittings | View details |
| Victaulic Style 912 FireLock Low Profile Sprinkler Tee | Pipes & Fittings | View details |
| Victaulic Style 927 FireLock Mechanical-T Branch Outlet | Pipes & Fittings | You are viewing this model |
Datasheets & Documents
- Datasheet Victaulic Style 927 FireLock Mechanical-T Branch Outlet Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Victaulic is an American maker of grooved mechanical pipe joining systems, valves and fire protection products, headquartered in Easton, Pennsylvania. Its grooved coupling was patented in 1919 by Ernest Tribe, and the name combines 'victory' and 'hydraulic'. Victaulic is privately held and reinvests in its own plants and technology.
Seven Star LLC lists Victaulic couplings and butterfly valves, among them the Style 107N QuickVic rigid coupling, and supplies Victaulic couplings and fittings for mechanical, utility and process piping in Oman on inquiry.
Victaulic company profile
| Origins | 1919, grooved coupling patent |
|---|---|
| Name | From 'victory' and 'hydraulic' |
| Headquarters | Easton, Pennsylvania |
| Ownership | Privately held |
| Product families | Style 07, 77 and 107N grooved couplings, Vic-300 MasterSeal butterfly valves, FireLock fire protection valves and sprinklers, grooved fittings and tools |
Milestones
- 1919: The grooved Victaulic coupling is patented.
- 2019: Victaulic marks 100 years.
Victaulic Style 107N QuickVic couplings
The Style 107N is a rigid coupling for roll-grooved or cut-grooved carbon steel and stainless steel pipe in sizes from 2 to 12 inches (DN 50 to DN 300). Victaulic rates it from full vacuum up to 750 psi (5171 kPa), but the working pressure of a given joint depends on pipe material, wall thickness and size. The housing has an angled bolt pad that makes the joint rigid, and a galvanized finish is optional.
Where Victaulic couplings are used and what to send
The manufacturer names HVAC, utility and process piping as the applications for this style. For an inquiry, send the style number, nominal size, pipe material and schedule, the fluid and temperature so the gasket grade can be checked, the housing finish and the quantity. GCC consultants often ask for the submittal sheet, which we provide from the manufacturer.
Facts checked against Victaulic's 100-year innovation timeline, October 2026.
Browse Victaulic products by category: Pipes & Fittings.
Victaulic products we list
FAQ
Questions about the Victaulic Style 927 FireLock Mechanical-T Branch
Answers from our engineering team on installation, compatibility and integration.
01What sizes does Victaulic Style 927 cover?
Run by branch sizes from 2 x 1 inch to 8 x 4 inch (DN50 x DN25 to DN200 x DN100), with threaded or grooved branches.
02What is the maximum working pressure of Victaulic Style 927?
363 psi (2503 kPa, 25 bar) on carbon steel pipe.
03Can Victaulic Style 927 be used outside fire protection?
The manufacturer designs it for fire protection systems only; other services should use different outlet products.
04What gasket does Victaulic Style 927 use?
Grade E EPDM on 2 x 1 to 2 x 1 1/2 inch, and Grade E Type EC EPDM with green and violet stripes on the larger combinations, both for ambient wet and oil free dry service.
05Is there a cross version of Victaulic Style 927?
Yes. The datasheet shows a Style 927 Cross that provides a branch on both sides of the run.


















Reviews
There are no reviews yet.