Brand:

Bürkert 126411 Type 6106 3/2-Way Rocker Solenoid Valve 1.2 mm 24 V DC

Description

Overview

When a pneumatic function needs a little more air than the smallest rocker valves can deliver, the Bürkert 126411 is the usual next step. It remains a 16 mm wide, direct-acting 3/2-way rocker solenoid valve from the Bürkert Type 6106 range and it is normally closed, but the orifice grows to 1.2 mm, the coil to 2 W and the pressure limit to 10 bar. Mounting is on the Bürkert sub-base. Seven Star LLC is an independent supplier serving Oman and the GCC.

Why a bigger orifice changes the numbers

Moving from 0.9 mm to 1.2 mm raises the standard nominal flow from 22 to 40 litres per minute for the path 1 to 2, and from 25 to 47 litres per minute for the path 2 to 3. That is an increase of roughly 80 percent in the first path and almost 90 percent in the second, which can halve the stroke time of a medium-sized single-acting cylinder. To keep the armature able to hold the larger seat against 10 bar, the coil is rated at 2 W instead of 1 W, so the heat generated by the valve is also higher and the designer should leave some air around it on a crowded manifold.

Specification of Bürkert 126411

Item Value
Article number Bürkert 126411
Circuit function C, 3/2-way, normally closed
Port connection Bürkert sub-base 16 x 27 mm
Orifice DN 1.2
Nominal power 2 W
Flow QNn, 1 to 2 40 l/min
Flow QNn, 2 to 3 47 l/min
Pressure range vacuum to 10 bar
Valve body / seal polyamide / FKM
Operating voltage 24 V DC, tolerance plus/minus 10 percent
Duty cycle 100 percent continuous operation
Medium neutral gases, 5 micrometre filtering
Medium and ambient temperature minus 10 to plus 55 degrees C
Switching frequency approx. 16 Hz
Electrical connection plug contacts to DIN EN 175301-803 form C, cable plug Type 2516 or rectangular plug Type 2505 (ordered separately)
Degree of protection IP65 with cable plug Type 2516; IP30 with rectangular plug Type 2505
Width 16 mm
Optional approval ATEX / IECEx Ex ia IIC T5, T6 Gb on request (explosion-proof variant draws 0.5 W)

How Bürkert 126411 differs from other Type 6106 variants

Consider the quartet of normally closed codes. The 0.9 mm Bürkert sub-base valve is 126417, 1 W, 22 and 25 l/min, 8 bar. The 1.2 mm Bürkert sub-base valve is this one, 2 W, 40 and 47 l/min, 10 bar. The CNOMO sub-base twin of this valve, 126414, is rated at 33 and 38 l/min instead, because the lateral CNOMO flow path is slightly more restrictive. The normally open counterpart is 126419. If you require less flow, step down to 126417; if you require another valve function, the normally open versions are the answer.

Where it is used in the field

Typical roles include driving double-acting cylinders through external amplification, switching vacuum generators on pick-and-place stations, and operating spool valves as pilot stage. Process industries in Oman use the same kind of valve in analysers, sampling systems and packaged skids where instrument air is limited to a few bar. Because the valve operates from vacuum up to 10 bar, it covers both pressure and suction duty with the same part.

Installation notes

Seat the sub-base seals before tightening the two M2.5 screws, and tighten alternately to avoid tilting the valve on its seal. Fit a cable plug Type 2516 for IP65 or a rectangular plug Type 2505 for IP30; both are ordered separately. Check the supply for ripple: the tolerance of plus/minus 10 percent includes the residual ripple of the supply. Use filtered, dry, neutral gas with 5 micrometre filtering. Run the manual override once to confirm free movement of the air path before connecting electricity.

Keep in mind the 2 W coil when sizing the 24 V supply for a long manifold. Ten valves energised together draw 20 W, which is still modest, but it should appear in the load calculation of the power supply and of the output cards that drive them.

Reliability and servicing

The rocker design is optimised for a very high switching life with low power consumption, and the valve may run continuously. Contamination, liquid carry-over and ice from wet compressed air are what shorten life, so keep dryers and filters in good condition. During overhauls replace the sub-base seals, inspect the plug gasket and verify that the manual override returns smoothly. Valves of this type are normally replaced and not repaired in the field.

Choosing between the two sub-base standards

Both the Bürkert and the CNOMO interface are common on European machinery, and Gulf plants inherit both. Before you place an order, identify the manifold on your machine and take a photograph of the valve mounting face with a ruler beside it. The Bürkert pattern measures 16 by 27 mm, while the CNOMO lateral pattern has a different spacing and a side connection. If you are unsure, send the photograph and the type plate data with your enquiry, and we will check which article number matches before the order is confirmed. This avoids the situation where a valve arrives that cannot be mounted on the machine and the stoppage is extended.

Compressed air and medium quality

Most early failures of small solenoid valves trace back to the medium and not to the valve. Compressed air from a hot climate carries a lot of water vapour, and when it cools in a long pipe the condensate ends up at the first valve with a small seat. Filtering, drying and draining must therefore be treated as part of the valve installation, not as an optional extra. Keep the dew point of the supply well below the lowest ambient temperature the pipe will see, fit auto-drains at low points and inspect filter elements on a fixed schedule. For water or oil service, a strainer upstream of the valve protects the seat from scale, welding residue and thread sealant fragments left over from construction.

Related items you may also need: Bürkert Type 8681 Control Head for Hygienic Process Valves | Bürkert Type 6026 Direct-Acting 2/2-Way Plunger Solenoid Valve | SMC VQC4101-5 Plug-in 5-Port Solenoid Valve VQC4000 | All Bürkert products.

Before you order the Bürkert 126411

  • To avoid a wrong delivery, compare the code on the nameplate of the installed unit with the Bürkert 126411 code on this page.
  • The quotation for the Bürkert 126411 states the confirmed code and the lead time to site.
  • The attached manufacturer datasheet covers the Bürkert 126411 ratings, dimensions and installation details.
  • Delivery of the Bürkert 126411 is arranged to project sites in Oman and across the GCC, alongside the rest of our solenoid valves range.
  • A spare Bürkert 126411 on the shelf is a simple way to protect critical service from long lead times.

Documents and quotation

The Type 6106 datasheet is attached to this page and includes the full ordering chart for this number, the manifold options and the connector types. Send your RFQ with Bürkert 126411, quantity and delivery location in Oman or the GCC.

Other Models in the 6106 Range

Seven Star LLC supplies models from the 6106 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Bürkert 126417 Type 6106 3/2-Way Rocker Solenoid Valve 24 V DCSolenoid ValvesView details
Bürkert 126411 Type 6106 3/2-Way Rocker Solenoid Valve 1.2 mm 24 V DCSolenoid ValvesYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Bürkert 126411 Type 6106 3/2-Way Rocker Solenoid Valve 1.2 mm 24 V DC Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Bürkert is a German family-owned maker of fluid control systems, headquartered in Ingelfingen, Baden-Württemberg. Christian Bürkert founded the company in 1946, and it is known for solenoid valves, process and control valves, flow and analytical sensors, and mass flow controllers. Its products serve water treatment, hygienic processing, gas handling and laboratory applications.

Seven Star LLC lists Bürkert valves and valve automation devices and supplies Bürkert solenoid valves and spare parts to plants in Oman as an independent supplier.

Bürkert company profile

Founded 1946, by Christian Bürkert
Headquarters Ingelfingen, Germany
Ownership Family-owned
Product families Solenoid valves, angle seat process valves, positioners, flow meters, mass flow controllers

Bürkert types listed on this page

Two types are listed. Type 6026 is a direct-acting 2/2-way plunger solenoid valve, with a stainless steel bellows that separates the medium from the coil, and as a direct-acting valve it switches without needing a pressure difference. Type 8681 is the Bürkert control head that mounts on top of hygienic process valves to pilot the actuator and report valve position to the control system. Control heads of this kind are common in food, beverage and pharmaceutical plants in the GCC.

Ordering Bürkert valves: what we need

The type number alone is not enough. Send the identification number from the label, or else the type with orifice, port connection, body and seal material, coil voltage and frequency, circuit function and pressure range. For a Type 8681 control head add the communication variant and the make and model of the process valve it sits on.

Facts checked against Bürkert's published company history, October 2026.

FAQ

Questions about the Bürkert 126411 Type 6106 3/2-Way Rocker Solenoid

Answers from our engineering team on installation, compatibility and integration.

01How does the Bürkert 126411 differ from the 126417?
It has a larger 1.2 mm orifice, a 2 W coil, 40 and 47 l/min nominal flow and a 10 bar limit, versus 0.9 mm, 1 W, 22 and 25 l/min and 8 bar.
02Which sub-base does the Bürkert 126411 fit?
It fits the Bürkert sub-base of 16 by 27 mm; the CNOMO lateral version of the same valve has a different article number, 126414.
03Is the Bürkert 126411 normally open or closed?
It is circuit function C, normally closed, with direct-acting 3/2-way operation and a manual override.
04What medium can run through the Bürkert 126411?
Neutral gases filtered to 5 micrometres, from minus 10 to plus 55 degrees C, from vacuum up to 10 bar.
05What electrical data does the 126411 have?
It runs on 24 V DC, 2 W, with plus/minus 10 percent tolerance, 100 percent duty cycle and form C plug contacts.