Brand:

Bürkert 145778 Type 0256 Brass 2/2-Way Solenoid Valve G3/8 8 mm Orifice

Description

Overview

For low-pressure, high-flow switching, the Bürkert 145778 stands at the generous end of the Type 0256 G3/8 range. It is a normally closed, direct-acting 2/2-way solenoid valve with brass body, 8 mm orifice, NBR seals and a 24 V DC coil. Because the seat is wide and the armature stroke is short, it is aimed at applications where the pressure is only a few hundred millibar and the pipe must not be starved. Seven Star LLC is an independent supplier serving Oman and the GCC.

What you can and cannot ask of it

The headline number is Kv 0.9 m3/h for water, the highest of the G3/8 brass group with a 56 mm body. The trade-off is the pressure window: with a DC coil on liquids the chart allows 0 to 0.5 bar only, with AC coils 0 to 1.5 bar, and for gases 0 to 2.5 bar. So the Bürkert 145778 is not a general-purpose water valve for mains pressure; it is for gravity feed, vented tanks, vacuum lines, blow-off at low pressure and similar duties. Technical vacuum is explicitly permitted for all material combinations in the datasheet.

Bürkert 145778 data sheet values

Item Value
Article number 145778
Valve body brass, 56 mm group
Port connection G3/8
Orifice 8 mm
Kv value (water) 0.9 m3/h
Pressure, liquids DC coil 0 to 0.5 bar
Pressure, liquids AC coil 0 to 1.5 bar
Pressure, gases 0 to 2.5 bar
Rated voltage 24 V DC
Seal material NBR
Operating medium neutral media, compressed air, water and oil with NBR; hot air and oils with additives with FKM; technical vacuum with all materials
Circuit function A, 2/2-way, direct-acting, normally closed
Coil epoxy, thermal insulation class H, 100 percent duty cycle
Electrical connection plug contacts to DIN EN 175301-803 form A, cable plug Type 2518 supplied
Degree of protection IP65 with cable plug
Voltage tolerance plus/minus 10 percent
Maximum viscosity 21 mm2/s (21 cSt)
Maximum ambient temperature 55 degrees C
Switching time AC opening 10 to 20 ms, closing 20 to 30 ms
Switching time DC opening 20 to 80 ms, closing 20 to 30 ms

Where it belongs

Think of header tanks in cooling circuits, gravity drain lines on lube-oil reservoirs, low-pressure pneumatic purges in analyser cabinets and vacuum handling stations. In Omani industry, such low-pressure jobs are common on packaged water treatment units, on wash and rinse stations in food and beverage plants, and on small oil-skimmer or drain systems. Because the coil is a DC type, the valve slots neatly into PLC-driven skids powered from a 24 V supply.

How Bürkert 145778 differs from other Type 0256 variants

The same G3/8 brass group offers 4 mm (Kv 0.5, 6 bar on DC liquids), 5 mm (Kv 0.65, 2.5 bar), 6 mm (Kv 0.8, 2 bar) and this 8 mm (Kv 0.9, 0.5 bar). The longer 74 mm brass body adds 10 mm (Kv 1.5, 0.4 bar) and, on G1/2, up to 12 mm (Kv 1.8, 0.1 bar). If your process has more than half a bar upstream of the valve on a DC coil, step down to one of the smaller orifices; if it has far less, the larger bodies provide still more flow.

Practical installation advice

Because the working pressure is low, leaks tend to be caused by poorly sealed threads and not by the valve itself, so take care with the sealant. Mount the valve where its coil cannot be covered in condensate and orient it with the coil upwards if possible. Wire the form A plug carefully, close it with the screw and gasket and verify IP65 integrity. Remember that DC coils take up to 80 ms to open, which matters in fast dosing sequences.

Choosing between low-pressure and standard variants

Engineers sometimes pick the largest orifice by reflex, assuming that more flow is always better. That habit causes problems with solenoid valves, because the force available to hold the seat closed falls as the orifice grows. A valve that is chosen too large for its pressure may fail to close against line pressure or may chatter when the coil heats up. The sensible approach is to define the maximum upstream pressure first, read the corresponding row in the pressure columns of the chart, and only then select the largest orifice that still satisfies the pressure limit. For this valve the limit is half a bar on liquids with a DC coil, and that figure should be treated as a hard boundary and not as a typical value.

It also helps to think about what happens at start-up and shutdown of the plant. A line that is pressurised briefly by a pump surge can exceed the rated pressure even if normal operation is well below it. If surges are possible, a smaller orifice with a higher pressure rating is the safer choice, or a pressure regulator can be placed upstream of the valve to keep the pressure inside the window.

Inspection routine

Look at the line strainer first: a clogged strainer upstream changes behaviour more than any valve fault. Then examine the plug, test the valve closed with the outlet vented, and check coil temperature. With a rated ambient up to 55 degrees C, valves in sunlit enclosures deserve a closer look during the Gulf summer.

Related items to quote with it

A low-pressure valve rarely arrives alone. Most buyers also need a cable plug for the form A contacts, a stainless or brass strainer to protect the wide seat from scale, and spare plug gaskets for the maintenance kit. On low-pressure water lines a simple in-line check of flow with a transparent hose can confirm that the valve opens completely before the circuit is handed over to operations. If the line carries oil, ask us to confirm that the NBR seal suits the specific oil grade; if the oil contains additives or runs hot, the FKM version of the same chart row is the correct alternative and carries a different article number.

Related items you may also need: Bürkert Type 8681 Control Head for Hygienic Process Valves | Bürkert Type 6026 Direct-Acting 2/2-Way Plunger Solenoid Valve | SAMSON Type 3969 Intrinsically Safe NAMUR Solenoid Valve | All Bürkert products.

Documents and quotation

The Type 0256 datasheet with the ordering chart for this article number is attached. Send your RFQ listing Bürkert 145778, quantity and delivery place in Oman or the GCC, plus any accessories you need.

Other Models in the 0256 Range

Seven Star LLC supplies models from the 0256 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Bürkert 145727 Type 0256 Brass 2/2-Way Solenoid Valve G1/4 24 V DCSolenoid ValvesView details
Bürkert 145731 Type 0256 Brass 2/2-Way Solenoid Valve G1/4 230 V ACSolenoid ValvesView details
Bürkert 145766 Type 0256 Brass 2/2-Way Solenoid Valve G3/8 24 V DCSolenoid ValvesView details
Bürkert 145778 Type 0256 Brass 2/2-Way Solenoid Valve G3/8 8 mm OrificeSolenoid ValvesYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Bürkert 145778 Type 0256 Brass 2/2-Way Solenoid Valve G3/8 8 mm Orifice Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Bürkert is a German family-owned maker of fluid control systems, headquartered in Ingelfingen, Baden-Württemberg. Christian Bürkert founded the company in 1946, and it is known for solenoid valves, process and control valves, flow and analytical sensors, and mass flow controllers. Its products serve water treatment, hygienic processing, gas handling and laboratory applications.

Seven Star LLC lists Bürkert valves and valve automation devices and supplies Bürkert solenoid valves and spare parts to plants in Oman as an independent supplier.

Bürkert company profile

Founded 1946, by Christian Bürkert
Headquarters Ingelfingen, Germany
Ownership Family-owned
Product families Solenoid valves, angle seat process valves, positioners, flow meters, mass flow controllers

Bürkert types listed on this page

Two types are listed. Type 6026 is a direct-acting 2/2-way plunger solenoid valve, with a stainless steel bellows that separates the medium from the coil, and as a direct-acting valve it switches without needing a pressure difference. Type 8681 is the Bürkert control head that mounts on top of hygienic process valves to pilot the actuator and report valve position to the control system. Control heads of this kind are common in food, beverage and pharmaceutical plants in the GCC.

Ordering Bürkert valves: what we need

The type number alone is not enough. Send the identification number from the label, or else the type with orifice, port connection, body and seal material, coil voltage and frequency, circuit function and pressure range. For a Type 8681 control head add the communication variant and the make and model of the process valve it sits on.

Facts checked against Bürkert's published company history, October 2026.

FAQ

Questions about the Bürkert 145778 Type 0256 Brass 2/2-Way Solenoid

Answers from our engineering team on installation, compatibility and integration.

01What is the water Kv of the Bürkert 145778?
The 8 mm orifice gives a Kv of 0.9 m3/h, the highest in the 56 mm brass body G3/8 group of Type 0256.
02Can the Bürkert 145778 be used on mains water pressure?
No, the DC liquid rating is only 0 to 0.5 bar, so it suits gravity feed and low-pressure lines; check the type plate before use.
03Does the Bürkert 145778 work on vacuum?
The datasheet lists technical vacuum as a permitted medium for all material combinations of the Type 0256 series.
04What supply does the Bürkert 145778 need?
It is the 24 V DC version with plus/minus 10 percent tolerance; 145779, 145780 and 145781 cover the AC voltages.
05Which seal material is in the 145778?
NBR, suitable for neutral media, air, water and oil from minus 10 to plus 80 degrees C.