Viking Pump HL8124A 30 GPM Mag Drive Internal Gear Pump
Description
Overview
Small pumps are often the hardest to seal, because high shaft speed and tight clearances punish a mechanical seal. Viking Pump HL8124A avoids the problem entirely. It is a cast iron internal gear pump driven magnetically through a 316L canister, delivering 30 GPM (7 m3/h) at 1750 rpm through 1 1/2 inch NPT ports in a package of just 60 lb (27 kg). Seven Star LLC is an independent supplier serving Oman and the GCC.
A compact sealless pump
Most internal gear pumps use a seal around a rotating shaft. This one does not. The shaft remains inside the casing, and the motor turns an outer magnet that carries the inner magnet through the canister wall. The result is a pump that suits small dosing and transfer duties on hazardous liquids, laboratory and pilot plants, and skid mounted packages in which space is tight but containment is vital.
Because it is dimensionally interchangeable with the Universal Product Line pump of the same size, it also serves as an upgrade for an existing sealed HL pump. The footprint stays the same and the piping does not move.
Viking Pump HL8124A facts and figures
| Parameter | Value |
|---|---|
| Model | Viking Pump HL8124A, series 8124A, sealless mag drive, catalog section 1403 |
| Port size | 1 1/2 inch (40 mm), tapped for NPT |
| Nominal capacity | 30 GPM (7 m3/h) at 1750 rpm |
| Casing, head and bracket | Cast iron, ASTM A48 Class 35B |
| Rotor | Cast iron ASTM A48 Class 35B; steel ASTM A148 Grade 80-50 optional |
| Rotor shaft and idler pin | Hardened steel, ASTM A108 Grade 1045 |
| Bushings | Carbon graphite standard; hardened cast iron or silicon carbide optional |
| Canister | 316L stainless steel |
| Magnets | Neodymium iron boron standard; samarium cobalt above 225 F (105 C) |
| Maximum hydrostatic pressure | 550 PSIG (38 bar) |
| Maximum discharge pressure | 200 PSIG (14 bar) |
| Temperature, standard pump | 225 F (105 C) |
| Temperature, high temperature construction | 500 F (260 C) |
| Viscosity range, series | 28 to 250,000 SSU (1 to 55,000 cSt) |
| Shipping weight with valve | 60 lb (27 kg) |
Choosing Viking Pump HL8124A instead of H8124A or K8124A
The H8124A is the smallest model in the series, with 15 GPM at 1750 rpm in the same 1 1/2 inch ports and the same 60 lb frame. The Viking Pump HL8124A doubles its flow to 30 GPM in the identical footprint. Moving up one frame to the K8124A raises the port to 2 inch and the weight to 195 lb, but drops the shaft speed to 780 rpm and lifts capacity to 80 GPM. So the HL is the right choice when the line is 1 1/2 inch, the flow target is around 30 GPM and a motor-speed direct drive is wanted.
Good applications
- Dosing of reactive chemicals from drums into reactors.
- Transfer of lubricants, fuel additives and light oils on equipment skids.
- Circulation of paint, ink and resin raw materials in batch plants.
- Sampling and loading duties where vapour escape must be avoided.
Details that matter in service
High motor speed means that the thrust control and bushings are working harder than in the large pumps, so the liquid must be clean and have some lubricity. Carbon graphite bushings are standard and tolerate dry starts for short periods, but they do not cope with abrasive solids. Use a strainer and verify that the liquid is compatible with the cast iron, carbon graphite and static O-ring materials.
The temperature limit is 225 F (105 C) with standard magnets. If the liquid goes hotter during steaming or flushing, tell the supplier so that samarium cobalt magnets are specified. Never run the pump against a closed valve; the internal relief valve bypasses liquid back to suction only for pressure relief, not for continuous recirculation.
Installation and start-up
Set the pump on its foot and align the motor through a flexible coupling. Rotate the casing before piping if you want a different port position; the standard ports can be turned in 90 degree steps. Prime the casing, open the suction and discharge valves and check the direction of rotation with a short bump. A small, steady rise in discharge pressure should follow within seconds of starting.
Materials and magnets
Casing, head and bracket are cast iron to ASTM A48 Class 35B. The rotor is cast iron, and the idler is cast iron as standard. The rotor shaft and idler pin are hardened steel to ASTM A108 Grade 1045, the canister is 316L stainless steel, and the bushings are carbon graphite with hardened cast iron or silicon carbide as options. Neodymium iron boron magnets are fitted as standard, with samarium cobalt available for hot service. In the smaller frame sizes the magnet torque is modest, so a sudden start against a blocked line will make the coupling slip rather than break the shaft, which is a protective feature.
Drive and speed notes
The 1750 rpm rating corresponds to a four pole motor on 60 Hz supply. On a 50 Hz network, a four pole motor turns at about 1450 rpm, and the delivered flow falls in proportion, so the quoted 30 GPM is a figure for the rated speed and not for every supply. Gulf networks run at 50 Hz, so consider that when sizing, and ask for the performance curve for your actual speed. The catalog also points to the Viking Pump curve generator for pressure and viscosity corrections.
If the liquid is thick, a gear reducer is better than a belt, since slow speed improves filling and reduces the torque peaks on the coupling. Keep the suction line short, and use a larger diameter for viscous products.
Related items you may also need: KRACHT KP 2/62 G10G Y00 4DL1 High-Pressure Gear Pump | Tapflo TD100 PE and PTFE Diaphragm Drum Pump | Verder VA25 Air-Operated Double Diaphragm Pump | All Viking Pump products.
Viking Pump HL8124A ordering checklist
- When the Viking Pump HL8124A replaces an installed unit, check the existing nameplate against the code on this page before ordering.
- Every enquiry for the Viking Pump HL8124A is answered with a written confirmation of the code and expected lead time.
- Use the attached datasheet to check the Viking Pump HL8124A ratings, dimensions and connection details against your drawings.
- We supply the Viking Pump HL8124A as part of our positive displacement pumps range to plants in Oman and the GCC.
Documents and quotation
The Viking catalog section for the 8124A series is attached, containing dimensions, materials and the model key. For a quotation on Viking Pump HL8124A, please send quantity, liquid, temperature and delivery location in Oman or the GCC, and mention the motor frame you plan to use.
Other Models in the Viking 8124a Range
Seven Star LLC supplies models from the Viking 8124a range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Viking Pump K8124A Sealless Mag Drive Internal Gear Pump | Positive Displacement Pumps | View details |
| Viking Pump L8124A 135 GPM Cast Iron Mag Drive Gear Pump | Positive Displacement Pumps | View details |
| Viking Pump LS8124A 200 GPM Mag Drive Internal Gear Pump | Positive Displacement Pumps | View details |
| Viking Pump Q8124A 300 GPM Mag Drive Internal Gear Pump | Positive Displacement Pumps | View details |
| Viking Pump QS8124A 500 GPM Mag Drive Internal Gear Pump | Positive Displacement Pumps | View details |
| Viking Pump HL8124A 30 GPM Mag Drive Internal Gear Pump | Positive Displacement Pumps | You are viewing this model |
Datasheets & Documents
- Datasheet Viking Pump HL8124A 30 GPM Mag Drive Internal Gear Pump Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Viking Pump is the American maker of positive displacement pumps best known for the internal gear pump, often described as the "gear-within-a-gear" design. The principle goes back to Jens Nielsen, a Danish-born quarry owner in Cedar Falls, Iowa, who needed a better way to drain water from his quarry and patented his internal gear pump in 1904. In 1911 Nielsen and three local partners formed the Viking Pump Company in Cedar Falls, which is still the company's home. Viking has been part of IDEX Corporation since 1989.
Viking Pump company profile
| Founded | 1911, Cedar Falls, Iowa, USA, by Jens Nielsen with P.C. Petersen, W.L. Hearst and George Wyth |
|---|---|
| Headquarters | Cedar Falls, Iowa, USA |
| Ownership | A unit of IDEX Corporation since 1989 |
| Core technology | Internal gear pumps (rotor, idler gear and crescent), plus external gear, vane, lobe and circumferential piston pumps |
| Typical liquids | Viscous and difficult liquids: fuel and lube oils, asphalt and bitumen, resins, polymers, chemicals, ammonia, molasses, inks and adhesives |
| Standards | API 676 versions for refinery and petrochemical service; jacketed and heated versions for liquids that must be kept hot |
Milestones
- 1904: Jens Nielsen patents his internal gear pump design.
- 1911: Viking Pump Company is founded in Cedar Falls, Iowa.
- 1989: Viking becomes part of IDEX Corporation.
- 2011: Viking marks 100 years in Cedar Falls.
- Today: Internal and external gear pumps, mag drive pumps and API 676 pumps sold through distributors worldwide.
How a Viking internal gear pump works
An internal gear pump has two moving parts: an outer rotor gear and a smaller idler gear that turns inside it, offset on a pin. A crescent-shaped partition on the head fills the space between them. As the gears come out of mesh on the suction side, liquid fills the opening tooth spaces, is carried around both sides of the crescent and is pushed out as the teeth mesh again on the discharge side. Flow is smooth and almost proportional to speed, so the same pump can handle thin solvents or very thick liquids. The pump is reversible, and an internal relief valve is often fitted to protect it if the discharge is blocked. For thick liquids, choose a larger pump at a lower speed; for hot products such as asphalt, choose a jacketed or heated version.
Where Viking pumps are used in Oman and the GCC
In the region, Viking pumps move fuel oil, lube oil and base oils in refineries and terminals, bitumen and asphalt in road-building and storage plants, resins and chemicals in petrochemical plants, and ammonia in refrigeration systems. External gear pumps such as the GB series are used for chemical injection into pipelines, and mag drive pumps are chosen where a seal leak is not acceptable.
Viking Pump models we list
| Family | Examples |
|---|---|
| General-purpose internal gear pumps | KK124C, H1124C O-Pro, QS124C, M124A, N324A, RS4324A |
| Jacketed and heated pumps | KK224C, Q224C, M224A, KK124E asphalt |
| Steel and stainless steel pumps | L123C, QS4123C, RS4323A, KK127C, Q4127C |
| API 676 pumps | LS4223AX, Q4223AX, N4323AX, R4323AX, KK4223AA |
| Motor speed, external gear and mag drive pumps | HL495, AK4195, GB-41013, GB-41430, SG-0741, AK893 mag drive |
| Special-duty pumps | KK4924A ammonia, KK4624C abrasive, LVP41027 vane |
Ordering Viking pumps: what we need
Send the full model number and serial number from the nameplate. The letters at the start of the model (for example G, H, KK, LS, Q or RS) give the pump size, and the digits give the construction, seal and material. For a new pump, tell us the liquid, its viscosity and temperature, the flow rate, the discharge pressure, the port size and whether you need a jacket, a relief valve, a motor and baseplate, or API 676 construction. For spares, send the model and serial number and say whether you need the rotor, idler, idler pin, bushing or seal kit.
Facts checked against Viking Pump and IDEX company history and published Viking product catalogues, November 2026.
Browse Viking Pump products by category: Positive Displacement Pumps.
FAQ
Questions about the Viking Pump HL8124A 30 GPM Mag Drive Internal Gear
Answers from our engineering team on installation, compatibility and integration.
01What is the capacity of the Viking Pump HL8124A?
The nominal rating is 30 GPM (7 m3/h) at 1750 rpm on medium viscosity liquid, through 1 1/2 inch NPT ports.
02How is the HL8124A different from the H8124A?
They share the 1 1/2 inch ports and 60 lb frame, but the HL delivers 30 GPM where the H delivers 15 GPM at the same 1750 rpm.
03How much does the HL8124A weigh?
The catalog shipping weight with relief valve is about 60 lb (27 kg), without motor, coupling or base.
04What is the pressure limit of the HL8124A?
The maximum hydrostatic pressure is 550 PSIG (38 bar), with a maximum recommended discharge pressure of 200 PSIG (14 bar).
05Does the HL8124A need a seal flush?
No. The sealless magnetic drive removes the shaft seal, so no seal flush or barrier system is needed.