- Automation & ControlView all 3,044 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- Encoders
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: SERVOMEX
Servomex S1802966 Hastelloy C-276 Sample Tubes Kit Oxy 1800
Description
Servomex S1802966 in plain terms
Servomex S1802966 is a kit of sample inlet and outlet tubes made from Hastelloy C-276 for the SERVOTOUGH Oxy 1800. It is a plumbing spare, not an electronic one: the tubes connect the 1/4 inch NPT sample ports on the underside of the casting to the transducer, and in the corrosive variant they must survive what the sample brings. The manual lists S1802966 in the sample option table for the solvent resistant / high-flow cell, immediately above the two transducer assemblies.
We describe it so that buyers can distinguish it from the stainless steel kit before a turnaround. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Facts taken from the manual
| Parameter | Value |
|---|---|
| Part number | S1802966 |
| Description | Sample Inlet and Outlet Tubes (Hastelloy C-276) Kit, 1 off |
| Counterpart | S1800966, Sample Inlet and Outlet Tubes (SS316) Kit |
| Option table | xendos 1800 sample option, solvent resistant / high-flow cell |
| Sample port thread | 1/4 inch NPT internal |
| Vent pressure limit | 11.5 to 18 psia, do not restrict |
| Particulates in sample | Below 3 micrometres |
| Condition of sample | Non-condensing at ambient temperature, no oil |
| Analyser mass | 26 kg |
Why Hastelloy matters here
Hastelloy C-276 is a nickel-molybdenum-chromium alloy that resists a wide range of acidic and chloride-bearing media better than 316 stainless steel. The manual does not elaborate on its chemistry; it simply assigns the alloy to the corrosive-sample configuration, noting that a corrosive sample needs the 1802 version. So use S1802966 when the sample is corrosive, and the standard S1800966 when it is clean.
Differences against other Oxy 1800 kits
- S1800966: SS316 tubes, standard option; the tubes in S1802966 differ in alloy only.
- S1802989B and S1806989B: transducers, not tubes; they complete the solvent resistant sample path.
- S1800988: back pressure regulator, a separate flow part for purity measurement.
Where corrosive samples occur
Think of chlorinated process gas streams, wet nitrogen with acid carryover, and flue-adjacent applications where acid gases can reach the sample line. In the Gulf region, sulfur-bearing streams in refining and gas processing are the typical cause of corrosion concerns, though you should treat the analyser sample as non-flammable as the manual requires.
Fitting the tubes
The tubes are replaced with the transducer exposed, so isolate and vent the sample, disconnect and flush with dry nitrogen for ten minutes, power down, and open the left cover with a 5 mm key. Use new seals from the enclosure seals kit S1800986 when closing, as the analyser is rated IP66 and NEMA 4X only when sealed properly. After reassembly leak-test slowly: the manual warns that fast pressure ramps create high internal flows that can damage the cell.
Inspection interval
Inspect tubes for discoloration or deposits whenever the transducer is serviced. If the sample is wet or dirty, check the conditioning upstream; the manual says as much when the filter element is found wet.
Order together
Typical order set: S1802966 plus S1802989B for a solvent resistant refurbishment, or S1802966 plus S1806989B for the fast variant.
Safe handling and risks around S1802966
Samples for which this tube kit is chosen may be toxic or asphyxiant. The manual advises verifying that all connections are leak free at full operating pressure before applying sample or calibration gas, and considering toxicity, corrosiveness and the asphyxiant nature of the sample and purge gas when choosing the vent location. Vent freely to atmosphere and never restrict the outlet.
Pressure during testing should be raised and lowered slowly. The cell is a delicate glass structure, and rapid flows produced by pressure steps can damage it long before the tubes themselves are affected. For gauge reference, the standard base analyser needs only about 0.3 kPa gauge at the inlet, while an automatic flow control device expects 7 to 35 kPa gauge.
Questions to settle before ordering S1802966
- Is the analyser an Oxy 1800 or an Oxy 1810, which has its own documents?
- Do the existing tubes show corrosion and does the sample contain acid gases?
- Is a matching transducer also due for replacement?
Installation sequence for the S1802966 kit
- Disconnect and flush the sample line with dry nitrogen or clean instrument air for ten minutes, then switch off the supply.
- Open the hinged left cover with a 5 mm key on the four M6 bolts, and use the display cover screw if the front is to be opened.
- Remove the old SS316 or Hastelloy tubes, noting the orientation of inlet and outlet.
- Fit S1802966, use fresh seals, close the covers fully and leak test slowly.
- Warm up for four hours, then zero and span.
Never run the analyser without its filter element where an automatic flow control device is fitted; the manual says dust and particulates can permanently damage the measuring cell, and the same logic applies to a freshly fitted tube set.
For purchasing records, note that S1802966 is a kit of two tubes, an inlet and an outlet, sold as one item, so a quantity of one covers a single analyser. If you operate several Oxy 1800 units in a corrosive duty, ask for S1802966 in multiples and keep one kit spare per site. Quote S1802966 together with the analyser serial number to avoid receiving the stainless steel S1800966 by mistake, because the two kits look alike on a packing list.
Documents and quotation
The Servomex SERVOTOUGH Oxy 1800 quick start manual, part number 01800003B revision 4, is the document we attach for Servomex S1802966; it carries the spares table, the sample condition table and the performance figures quoted on this page. Please state whether you also need the matching transducer, as the tube kit alone does not include it. To request a quotation, send the part number S1802966, the quantity, the analyser serial number if you have it, and the delivery location in Oman or elsewhere in the GCC. We reply to each RFQ with availability and lead time.
Other Models in the Servomex Oxy1800 Range
Seven Star LLC supplies models from the Servomex Oxy1800 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Servomex S1806989B Solvent Resistant High-Flow O2 Transducer | Gas Analyzer Systems | View details |
| Servomex S1802989B Solvent Resistant O2 Transducer Oxy 1800 | Gas Analyzer Systems | View details |
| Servomex S1800989B Standard O2 Transducer for Oxy 1800 | Gas Analyzer Systems | View details |
| Servomex S1804989B High-Flow O2 Transducer for Oxy 1800 | Gas Analyzer Systems | View details |
| Servomex S1800912A 4.5 Digit Display PCB for Oxy 1800 | Gas Analyzer Systems | View details |
| Servomex S1802966 Hastelloy C-276 Sample Tubes Kit Oxy 1800 | Gas Analyzer Systems | You are viewing this model |
Datasheets & Documents
- Datasheet Servomex S1802966 Hastelloy C-276 Sample Tubes Kit Oxy 1800 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Servomex is a British specialist in gas analysis, founded in 1952 by Richard Steel, John Crockett and Ronald Mudie; the name comes from servomechanism. It first made electronic products, then built its first paramagnetic oxygen analyser in 1961 after work with Charles Munday on a paramagnetic sensor. Servomex is based in Crowborough, East Sussex, and is part of Spectris.
Seven Star LLC lists Servomex process, combustion, emissions and portable gas analyzers, plus accessories, and sources them for refineries, petrochemical plants and industrial gas producers in Oman.
SERVOMEX company profile
| Founded | 1952, United Kingdom |
|---|---|
| Founders | Richard Steel, John Crockett and Ronald Mudie |
| Headquarters | Jarvis Brook, Crowborough, East Sussex |
| Ownership | Spectris plc, since 1999 |
| Key technologies | Paramagnetic oxygen sensing (1961), infrared analysis (1969), zirconia oxygen sensors (1981) |
| Product families | MultiExact and SERVOPRO MultiExact analysers, SERVOTOUGH OxyExact and Oxy 1800 oxygen analysers, SERVOTOUGH Laser 3 Plus TDL analysers, SERVOFLEX portable analysers, zirconia combustion analysers |
Milestones
- 1952: Servomex is founded.
- 1961: The first Servomex paramagnetic oxygen analyser is introduced.
- 1981: Servomex introduces zirconia oxygen sensors.
- 1999: Spectris acquires Servomex.
Servomex analyzer families listed
Servomex groups its analyzers under family names that indicate where they can be used. SERVOTOUGH covers analyzers built for hazardous areas and field mounting, SERVOPRO covers units for general purpose areas and analyzer houses, and SERVOFLEX is the portable line. On this page:
- SERVOTOUGH OxyExact 2200: paramagnetic oxygen analyzer for process control and safety
- SERVOTOUGH SpectraExact 2500: photometric analyzer for process gas components
- SERVOTOUGH Laser 3 Plus: compact tunable diode laser analyzer for combustion
- SERVOPRO 4900 Multigas: multi-component analyzer for emissions monitoring
- SERVOPRO NanoTrace DF-550E: ultra-trace oxygen analyzer for high purity gases
- SERVOFLEX Micro i.s. 5100: intrinsically safe portable oxygen analyzer
A flow alarm relay box for the 2700 flue gas analyzer is also listed.
Where Servomex gas analyzers are used
Typical duties are oxygen measurement for inerting and blanketing, vapor recovery and flare header safety, combustion control on fired heaters and reformers, purity control in air separation and electronic gases, and continuous emissions monitoring. In the GCC the main users are refining, petrochemicals, fertilizer, LNG and industrial gas plants.
SERVOMEX products we list
Ordering Servomex analyzers and spares: what we need
A Servomex gas analyzer is built to an order code that fixes the measured gas, range, sample wetted materials, outputs and hazardous area approval. For replacements and spare parts, send the model, the serial number and the order code from the data plate. For a new Servomex oxygen analyzer or multigas unit, send the full stream composition, the component and range to be measured, sample pressure and temperature, the area classification, power supply and communication needs. We check the configuration against Servomex documentation before quoting.
Facts checked against Servomex's own 70-year history and company profiles, October 2026.
Browse SERVOMEX products by category: Gas Analyzer Systems, Gas Analyzer Accessories, Portable Test & Measurement.
FAQ
Questions about the Servomex S1802966 Hastelloy C-276 Sample Tubes Kit
Answers from our engineering team on installation, compatibility and integration.
01What is in Servomex S1802966?
The manual calls it the sample inlet and outlet tubes kit in Hastelloy C-276, listed under the Oxy 1800 solvent resistant / high-flow sample option.
02What does S1802966 replace?
It is the corrosion-resistant counterpart of S1800966, the 316 stainless steel inlet and outlet tubes kit used with the standard sample option.
03Why choose Hastelloy C-276 tubes?
The manual notes that corrosive samples require the 1802-type configuration; Hastelloy C-276 is the tube material it lists for that case.
04Does the kit include the transducer?
No. The transducer assemblies are separate parts such as S1802989B and S1806989B.
05What are the connection sizes on the analyser?
Sample inlet, outlet, purge and breather ports are 1/4 inch NPT female, per the manual figure key.


















Reviews
There are no reviews yet.