Brand: SERVOMEX
Servomex S1804989B High-Flow O2 Transducer for Oxy 1800
Description
Servomex S1804989B: the fast-flow oxygen cell
Servomex S1804989B is the high-flow O2 transducer assembly in the xendos 1800 Series spares table. Where the standard cell is fed with a gentle 50 to 250 millilitres per minute, this version is built for sample passing at tens of litres per hour, a regime common in plants where the sample line is long and a slow stream would delay every reading. The manual gives it its own column in the performance table, headed high flow transducers: standard or solvent resistant.
This page assists buyers and maintenance teams who need to verify the part against an Oxy 1800 nameplate before ordering. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Performance figures that define S1804989B
| Parameter | Value |
|---|---|
| Part number | S1804989B |
| Manual description | High-flow O2 Transducer Assy., 1 off |
| Response time T90 | Less than 5 seconds |
| Noise, peak to peak | Less than 0.04 percent O2 |
| Sample flow rate effect | Less than 0.2 percent O2 over 50 to 70 litres per hour |
| Ambient pressure coefficient | 1 percent of reading per 1 percent pressure change |
| Intrinsic error | Less than 0.2 percent of reading or 0.05 percent O2 |
| Zero drift | Less than 0.05 percent O2 per week |
| Measurement range | 0.0 – 100.0 percent O2 |
| Connections | 1/4 inch NPT female inlet and outlet |
| Vent pressure | 11.5 to 18 psia, do not restrict |
Why a fast-flow cell shortens response
In a paramagnetic analyser the response is limited by how quickly the cell volume is exchanged. By accepting a higher volumetric flow, the cell is purged faster, so a step change in oxygen at the sampling point appears on the display and 4-20 mA output sooner. For purity control loops in air separation or blanketing control, that cuts the dead time the controller has to fight. S1804989B therefore suits analysers placed far from the tapping point, or sample systems that already carry a high flow by design.
How S1804989B differs from sibling transducers
- Compared with S1800989B, the flow window moves from 50 to 250 ml/min to 50 to 70 litres per hour, and T90 is under 5 seconds with the sample moving at 60 litres per hour in the manual note.
- Compared with S1802989B, there is no change of elastomer: S1804989B does not carry the Chemraz seals.
- Compared with S1806989B, S1804989B lacks solvent resistance but is otherwise the same fast-flow concept.
Applications in industrial plants
Examples include nitrogen header monitoring at industrial gas plants, oxygen-in-inert checks at long pipeline tapping points on utilities, and furnace atmosphere control where the sample must travel a distance in a heated sample line before reaching the analyser. These installations are typical in Oman and the Gulf, where plant layouts can be large and ambient temperature high. Remember the operating range of the analyser: minus 10 to plus 50 degrees Celsius, so keep the housing shaded or in an enclosure on exposed sites.
Installation and commissioning checks
Run the sample through a filter capable of stopping particles larger than 3 micrometres, keep the sample non-condensing, and vent freely. Allow a four-hour warm-up before introducing gas. Because high flow carries more moisture and particulates through the cell, confirm that the upstream conditioning is sized for the flow before commissioning. Calibrate with nitrogen and instrument air at the flows given in the manual, and never exceed the limits during leak testing; the manual warns that rapid pressure changes can create high internal flows that damage the measuring cell.
Maintenance and replacement
The transducer is replaced as a complete assembly by trained staff following service manual 01800002B. Before work, disconnect the sample and flush the pipework with dry nitrogen or instrument air for ten minutes, per the shutdown procedure in the manual, then remove power. Keep records of the date of replacement and the calibration results; a high-flow cell sees more contamination, so shorter intervals between filter changes than the 3 months suggested for clean service may be sensible.
Related Oxy 1800 spares
Pair S1804989B with the AFCD filter element kit S1800985 if an automatic flow control device is fitted, and with the S1800988 back pressure regulator where purity measurements must be protected from barometric swings.
Practical limits of the high-flow cell S1804989B
Fast flow is only an advantage if the sample is delivered cleanly. The manual keeps the same particulate limit of below 3 micrometres and the same requirement that sample be free from oil and condensate, so a coalescing filter and a short, heated sample line remain good practice. If the oxygen content is above 21 percent, span with a certified gas instead of air.
Commissioning record for S1804989B
After installation, log the flow in litres per hour, the vent pressure, the zero reading on nitrogen and the span reading on air. The manual defines the performance with a noise level below 0.04 percent O2 peak to peak for the high-flow cells, so a noisy trace after fitting usually points to pressure pulsing, which a reservoir ahead of the analyser can reduce when an external pump is used. Keep these records beside the part number S1804989B so the next service engineer has a baseline for the next exchange.
Documents and quotation
The Servomex SERVOTOUGH Oxy 1800 quick start manual, part number 01800003B revision 4, is the document we attach for Servomex S1804989B; it carries the spares table, the sample condition table and the performance figures quoted on this page. State whether your sample line already delivers the high flow range or relies on a bypass, so we can check the cell type. To request a quotation, send the part number S1804989B, the quantity, the analyser serial number if you have it, and the delivery location in Oman or elsewhere in the GCC. We reply to each RFQ with availability and lead time.
Other Models in the Servomex Oxy1800 Range
Seven Star LLC supplies models from the Servomex Oxy1800 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Servomex S1806989B Solvent Resistant High-Flow O2 Transducer | Gas Analyzer Systems | View details |
| Servomex S1802989B Solvent Resistant O2 Transducer Oxy 1800 | Gas Analyzer Systems | View details |
| Servomex S1800989B Standard O2 Transducer for Oxy 1800 | Gas Analyzer Systems | View details |
| Servomex S1804989B High-Flow O2 Transducer for Oxy 1800 | Gas Analyzer Systems | You are viewing this model |
| Servomex S1800912A 4.5 Digit Display PCB for Oxy 1800 | Gas Analyzer Systems | View details |
| Servomex S1802966 Hastelloy C-276 Sample Tubes Kit Oxy 1800 | Gas Analyzer Systems | View details |
Datasheets & Documents
- Datasheet Servomex S1804989B High-Flow O2 Transducer for Oxy 1800 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Servomex is a British specialist in gas analysis, founded in 1952 by Richard Steel, John Crockett and Ronald Mudie; the name comes from servomechanism. It first made electronic products, then built its first paramagnetic oxygen analyser in 1961 after work with Charles Munday on a paramagnetic sensor. Servomex is based in Crowborough, East Sussex, and is part of Spectris.
Seven Star LLC lists Servomex process, combustion, emissions and portable gas analyzers, plus accessories, and sources them for refineries, petrochemical plants and industrial gas producers in Oman.
SERVOMEX company profile
| Founded | 1952, United Kingdom |
|---|---|
| Founders | Richard Steel, John Crockett and Ronald Mudie |
| Headquarters | Jarvis Brook, Crowborough, East Sussex |
| Ownership | Spectris plc, since 1999 |
| Key technologies | Paramagnetic oxygen sensing (1961), infrared analysis (1969), zirconia oxygen sensors (1981) |
| Product families | MultiExact and SERVOPRO MultiExact analysers, SERVOTOUGH OxyExact and Oxy 1800 oxygen analysers, SERVOTOUGH Laser 3 Plus TDL analysers, SERVOFLEX portable analysers, zirconia combustion analysers |
Milestones
- 1952: Servomex is founded.
- 1961: The first Servomex paramagnetic oxygen analyser is introduced.
- 1981: Servomex introduces zirconia oxygen sensors.
- 1999: Spectris acquires Servomex.
Servomex analyzer families listed
Servomex groups its analyzers under family names that indicate where they can be used. SERVOTOUGH covers analyzers built for hazardous areas and field mounting, SERVOPRO covers units for general purpose areas and analyzer houses, and SERVOFLEX is the portable line. On this page:
- SERVOTOUGH OxyExact 2200: paramagnetic oxygen analyzer for process control and safety
- SERVOTOUGH SpectraExact 2500: photometric analyzer for process gas components
- SERVOTOUGH Laser 3 Plus: compact tunable diode laser analyzer for combustion
- SERVOPRO 4900 Multigas: multi-component analyzer for emissions monitoring
- SERVOPRO NanoTrace DF-550E: ultra-trace oxygen analyzer for high purity gases
- SERVOFLEX Micro i.s. 5100: intrinsically safe portable oxygen analyzer
A flow alarm relay box for the 2700 flue gas analyzer is also listed.
Where Servomex gas analyzers are used
Typical duties are oxygen measurement for inerting and blanketing, vapor recovery and flare header safety, combustion control on fired heaters and reformers, purity control in air separation and electronic gases, and continuous emissions monitoring. In the GCC the main users are refining, petrochemicals, fertilizer, LNG and industrial gas plants.
SERVOMEX products we list
Ordering Servomex analyzers and spares: what we need
A Servomex gas analyzer is built to an order code that fixes the measured gas, range, sample wetted materials, outputs and hazardous area approval. For replacements and spare parts, send the model, the serial number and the order code from the data plate. For a new Servomex oxygen analyzer or multigas unit, send the full stream composition, the component and range to be measured, sample pressure and temperature, the area classification, power supply and communication needs. We check the configuration against Servomex documentation before quoting.
Facts checked against Servomex's own 70-year history and company profiles, October 2026.
Browse SERVOMEX products by category: Gas Analyzer Systems, Gas Analyzer Accessories, Portable Test & Measurement.
FAQ
Questions about the Servomex S1804989B High-Flow O2 Transducer for Oxy
Answers from our engineering team on installation, compatibility and integration.
01What is special about Servomex S1804989B?
S1804989B is the high-flow O2 transducer assembly, designed so sample can pass at tens of litres per hour for a quicker response than the base cell.
02What response time does the high-flow cell give?
The manual specifies a T90 of less than 5 seconds for the high-flow transducers, against less than 4 seconds for the base analyser and 7 seconds with AFCD.
03What flow range applies to S1804989B?
The flow rate effect is stated as less than 0.2 percent O2 over 50 to 70 litres per hour for the high-flow transducers.
04Does S1804989B tolerate solvents?
No, it is the standard-material high-flow cell. The solvent resistant high-flow version is S1806989B.
05Which part do I order for a corrosive, fast-flow stream?
Order S1806989B together with the Hastelloy tube kit S1802966.