Brand: Panametrics
Panametrics C-ET Clamp-On Waveguide Transducer System
Description
Panametrics C-ET overview
The Panametrics C-ET is a clamp-on extended temperature transducer system for liquid flow measurement. A solid waveguide, which the manufacturer compares to a thin ice hockey stick, lifts the C-RS transducer away from the pipe wall so the piezoelectric element stays well inside its own operating range even when the process is extremely hot or extremely cold. It is the latest generation of the older OKS buffer transducer system and is designed for use with Panametrics DigitalFlow ultrasonic flow meters.
For buyers in Oman and the wider Gulf, the C-ET is a part that is searched for by exact model name, because the equipment it belongs to often stays in service for many years. This page describes the C-ET clamp-on waveguide transducer system using only information published by the manufacturer, so that you can confirm the model before you send a request for quotation. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Key features of the Panametrics C-ET
The manufacturer highlights the following points for the C-ET.
- Waveguide technology for process temperatures up to 400 C (750 F) and down to -200 C (-328 F).
- Clamp-on installation, so no process shutdown and no penetration into the pipe.
- No pressure drop, no leak path and no clogging risk.
- Bi-directional measurement with low flow capability down to 0.03 m/s (0.1 ft/s).
- No drift and no periodic calibration, with little or no maintenance.
- Two ultrasonic frequencies, 0.5 MHz and 1 MHz, for different liquids.
- Mounting with a stainless steel V-style clamping fixture or a PI-style chain fixture using solid couplant.
Together these points explain why the C-ET remains a practical choice where the measurement must be dependable and where service access is limited. Each statement above comes from the published datasheet, and nothing has been added beyond it.
Technical specifications of the C-ET
| Parameter | Value |
|---|---|
| Pipe sizes | 3 to 24 in (80 to 600 mm) NB and larger |
| Pipe wall thickness | Up to 3 in (80 mm) |
| Accuracy, pipe ID above 6 in | 1 to 2 percent of reading (velocity) |
| Accuracy, pipe ID below 6 in | 2 to 5 percent of reading (velocity) |
| Process temperature | -200 to 400 C (-328 to 750 F) |
| Ambient temperature | -40 to 75 C (-40 to 167 F) |
| Frequencies | 0.5 MHz or 1 MHz (C-RS transducers) |
| Materials | Stainless steel fixture and waveguide; stainless steel and plastic transducer; coated aluminum holder |
| Certifications (integral C-RS) | CSA Class 1 Div 1 Groups B, C, D; ATEX II 2 GD Eex md IIC T6 |
| Fixtures | V4, V8, V12 brackets for 3 to 12 in pipes; PIC chain for 8 to 24 in pipes |
| Couplants | Numbers 12, 13, 14, 15 depending on temperature range |
Values are taken from the manufacturer datasheet for the C-ET; always confirm against the current document, because ranges, certifications and options depend on the exact configuration that is ordered.
Typical applications for the C-ET in Oman and the GCC
The C-ET is applied in refinery coker, crude and vacuum distillation, cracker, hydrotreater and visbreaker lines, power plant boiler feed water, heat transfer oil loops and cryogenic liquid duties in the Gulf region.
In oil and gas, the C-ET supports process monitoring where an accurate reading helps operators protect equipment and keep production stable. In utilities and water, it gives plant teams a measurement they can trust for balance and efficiency checks. In general manufacturing, it is used wherever the process fluid or gas has to be controlled closely. The hot climate and demanding duty of the region put extra weight on dependable instruments, so spare availability of the C-ET matters to maintenance planners.
Selection and compatibility notes for the C-ET
The ordering code of the C-ET describes a pair of C-RS transducers with waveguide, mounting fixture and couplant. You choose the frequency (05 for 0.5 MHz or 10 for 1 MHz), the junction box option (none, CSA aluminum, ATEX aluminum or ATEX stainless steel), the fixture size (V4, V8, V12 or PIC), the pipe outer diameter and the couplant number. Couplant 13 covers -200 to 100 C, while couplants 12, 14 and 15 are listed for the high-temperature end. Accuracy assumes a fully developed profile, typically ten diameters upstream and five downstream, and a velocity above 0.3 m/s.
If you are replacing an existing C-ET, the safest approach is to read the nameplate, note the full model code, serial number and any certification marking, and send those details with your enquiry. This avoids mismatches in mounting, connector or range, which are the most common causes of a replacement that does not fit.
Installation and commissioning of the C-ET
Follow the installation guide or user manual that belongs to your meter or analyzer. Before fitting the C-ET, check that the process conditions, including temperature, pressure and fluid, are inside the limits in the specification table. Confirm the cable or connector type, use the recommended wiring and keep signal cables away from power cabling. After mounting, verify the reading against a known reference or an expected process value and record the configuration so that later maintenance can repeat it. In hazardous areas, install only with the certified accessories and follow the local code of practice.
Maintenance and service life of the C-ET
Routine care for the C-ET consists of visual inspection of the connector, cable, seals and mounting hardware, checking the reading for drift or noise, and keeping the surface free of deposits where that applies to the design. Keep a spare on the shelf for critical measurements, since lead times for specialist parts can be long. Recalibration or exchange intervals should follow the manufacturer recommendation for the instrument system in which the C-ET operates.
Related products and ordering notes for the C-ET
The C-ET is one member of the wider Panametrics range of flow, moisture, oxygen and gas measurement equipment. Related items on this site include other Panametrics analyzers and flow meters. When ordering, give the exact part or model code, the quantity, the meter or analyzer it will connect to and the delivery location. Do not rely on the family name alone, because the C-ET family has several configurations.
Frequently asked questions about the C-ET
The questions below summarize what buyers most often ask about the Panametrics C-ET: what it is, where it is used, which conditions it handles and how to order a matching part. The answers are drawn from the published datasheet. For anything that depends on a specific configuration, send us the nameplate data and we will help confirm the match before quoting.
Documents and quotation
A manufacturer datasheet for the C-ET is attached to this page. To request a quotation, send the RFQ with the part number C-ET, the full model code from your nameplate and the quantity you need, and our team will respond with availability and lead time. C-ET enquiries from Oman and the GCC are welcome.
Datasheets & Documents
- Datasheet Panametrics C-ET Clamp-On Waveguide Transducer System Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Panametrics is an American maker of ultrasonic flowmeters and moisture, oxygen and gas analysers. It was founded in 1960 and was based in Waltham, Massachusetts, when GE bought it in 2002. It later became a Baker Hughes business, and since 1 January 2026 it has belonged to Crane Company. Its long-running site in Shannon, Ireland, opened in 1973.
Seven Star LLC lists Panametrics flowmeters and analyzers for buyers in Oman: DigitalFlow gas and flare meters, clamp-on and portable liquid meters, and trace moisture analyzers for natural gas and process gases. We are an independent supplier, so each inquiry is checked against the manufacturer's order string before a quotation goes out.
Panametrics company profile
| Founded | 1960, Massachusetts, USA |
|---|---|
| Main sites | Billerica, Massachusetts, and Shannon, Ireland (since 1973) |
| Ownership | Crane Company since 1 January 2026; previously GE (from 2002) and Baker Hughes |
| Key technology | Transit-time ultrasonic flow measurement and aluminium oxide moisture sensing |
| Product families | TransPort PT900 portable and DigitalFlow fixed ultrasonic flowmeters for liquid, gas and flare gas, aluminium oxide moisture probes and hygrometers, Aurora laser moisture analysers, XMO2 oxygen and XMTC thermal conductivity transmitters |
Milestones
- 1960: Panametrics is founded.
- 1973: The Shannon, Ireland, site is established.
- 2002: GE acquires Panametrics.
- 2026: Crane Company completes its purchase of Baker Hughes' Precision Sensors & Instrumentation, including Panametrics.
Panametrics product families on this page
The listed items follow the manufacturer's own grouping:
- Gas and flare flow: DigitalFlow GF868 flare gas meter, GM868 and XGM868i gas flow transmitters
- Liquid flow: XMT1000 transmitter, AT600 AquaTrans clamp-on meter, TransPort PT900 portable meter
- Moisture: moisture.IQ multichannel analyzer, HygroPro II aluminum oxide transmitter, Aurora TDLAS analyzer for natural gas
Older units may carry GE Panametrics or GE Sensing on the nameplate. They belong to the same product lines, and the model string is read the same way.
Where Panametrics flowmeters and moisture analyzers are used
Flare meters report flared volumes on production sites, refineries and LNG plants. Clamp-on and portable ultrasonic meters check water, hydrocarbon liquid and utility lines without cutting the pipe. Aluminum oxide and TDLAS moisture analyzers watch dehydration units, gas pipelines, hydrogen and industrial gas streams. The manufacturer also names chemical processing, energy and water and wastewater among its markets, which matches what GCC operators ask us for.
Panametrics products we list
Ordering Panametrics equipment: what we need
A Panametrics model is a long configuration string, and the transducers or probes are ordered separately. Please send the full model and serial number of the electronics, the transducer or moisture probe part number, pipe size, schedule and material, fluid, pressure and temperature, flow range, hazardous area approval and output or protocol. For a flare meter add the flare gas composition range and velocity range. For moisture, give the dew point range and whether sample system components are required.
Facts checked against GE's 2002 acquisition release, Crane Company's January 2026 completion release and Irish press, October 2026.
FAQ
Questions about the Panametrics C-ET Clamp-On Waveguide Transducer
Answers from our engineering team on installation, compatibility and integration.
01What is the Panametrics C-ET?
The Panametrics C-ET is a extended temperature clamp-on ultrasonic transducer system. It is described in the manufacturer datasheet referenced on this page.
02Where is the C-ET typically used?
The datasheet and application notes point to uses such as refinery coker and similar process duties.
03What are the key specifications of the C-ET?
Pipe sizes: 3 to 24 in (80 to 600 mm) NB and larger; Pipe wall thickness: Up to 3 in (80 mm). See the specifications table for the full list.
04How do I make sure I order the correct C-ET?
Send the full model code, nameplate details and the instrument it connects to. Many Panametrics items are configured by code, so every field must match.
05Is Seven Star LLC affiliated with the manufacturer of the C-ET?
No. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number and quantity.