Brand: Panametrics
Panametrics PanaFlow HT SIL Ultrasonic Flow Meter for Liquids
Description
Panametrics PanaFlow HT overview
The Panametrics PanaFlow HT is a SIL-rated wetted ultrasonic flow meter for liquids in nominal or extremely high or low process temperatures. The manufacturer describes it as the first ultrasonic flow meter to receive SIL certification under IEC 61508. It is aimed at safety-critical duty such as coker flow metering, where reliable measurement reduces risk to personnel, plant assets and the environment.
The system consists of the XMT1000 electronics, the Bundle Waveguide Technology (BWT) transducer system and a factory-assembled meter body, so installation is largely a matter of bolting the end flanges in place. The buffers use waveguide bundles to concentrate ultrasonic energy into the process while protecting the transducers from extreme temperature, and pulse-echo measurement of dead time keeps accuracy as process temperature changes. Panametrics PanaFlow HT is a SIL2 meter as a single design, with SIL3 capability in a redundant design configuration.
Key features of the PanaFlow HT
- IEC 61508 certified: SIL2 single design, SIL3 with redundant design.
- Flow measurement from -200 deg C to 600 deg C process temperature applications.
- No drifting, no periodic calibration, no maintenance, no restriction in the pipe.
- Bidirectional measurement with 400:1 rangeability.
- Active temperature compensation using pulse echo.
- Configurations 1P1R, 2P1R, 1P2R, 1P3R, 1P4R and 2P4R.
- XMT1000 transmitter with explosion-proof/flameproof enclosure, HART 7.0, Foundation Fieldbus and RS485/Modbus.
PanaFlow HT technical specifications
| Parameter | Value |
|---|---|
| Fluid types | Liquids; acoustically conductive, small amounts of entrained solids or gas |
| Meter sizes | 3 in to 16 in (80 mm to 600 mm) standard; up to 72 in on request |
| Body materials | Carbon steel A106 Gr. B, stainless steel 316/316L, or 9Cr-1Mo; others on request |
| Accuracy | Plus or minus 0.5 percent of reading (3-4 in: 7 to 40 ft/s; 6-36 in: 3 to 40 ft/s); plus or minus 0.9 percent for 3-4 in at 3 to 7 ft/s |
| Repeatability | Plus or minus 0.25 percent of reading (plus or minus 0.5 percent at lower velocities) |
| Range | 0.1 to 40 ft/s (0.03 to 12.19 m/s) bidirectional; 400:1 |
| Transducer temperature | Normal -190 to 315 deg C; high temperature -190 to 600 deg C |
| Pressure | Up to ANSI 600; optional up to ANSI 2500 |
| Transducer certifications | Class I Division 1 Groups B, C, D; ATEX II 2 G Ex d IIC T6; IECEx Ex d IIC T6 |
| Enclosure | Aluminum (copper free) or SS316, IP66/IP67 |
| Power | 100-240 VAC, 50/60 Hz; optional 12-28 VDC |
| Ambient temperature | -40 to 65 deg C |
| Standard outputs | One 4-20 mA (NAMUR NE43) and one pulse or frequency output; SIL 4-20 mA optional |
| Digital interfaces | RS485/Modbus standard; HART 7.0 or Foundation Fieldbus optional |
The datasheet includes an ordering matrix for the meter body, configuration, transducer and electronics options, so the RFQ must be matched to that matrix.
Typical applications in Oman and the GCC
Applications named include coker crude distillation, vacuum distillation, crackers, hydrotreaters, visbreakers, crude oil and LNG. In the GCC the PanaFlow HT is relevant for refinery units where high temperature and safety instrumented functions are in scope.
Selection and compatibility notes
Specify line size, flange rating, material, temperature, SIL level and configuration (single path or redundant). Confirm whether the flow meter is part of a safety instrumented function so the SIL 4 to 20 mA output option is included.
Functional safety purchases are more than a product choice. A SIL claim depends on the full safety instrumented function, the proof-test interval and the system architecture. Share the safety requirement specification and the target SIL with the supplier and your safety engineer so that the configuration (for example single path or one of the redundant options) matches the calculated need.
Because the meter body is assembled at the factory, pipe spool dimensions, flange facings and material certificates should be confirmed before order placement. Material test certificates and any inspection requirements for coker or high temperature service should be listed in the RFQ.
Installation and commissioning
The meter body is delivered with the necessary components installed. Provide the typical straight run of 10 diameters upstream and 5 downstream for a fully developed profile, avoid piping that induces swirl, and bolt in the flanges. Wire the XMT1000 per its manual.
Maintenance and service life
The datasheet states there is no maintenance and no periodic calibration requirement, and transducers can be accessed at any time. Follow your site proof-test procedure for SIS applications.
Related products and ordering notes
Related products are the XMT868i and DF868 for non-SIL liquid service. For a PanaFlow HT RFQ, give the ordering matrix choices, line size, material and SIL requirement. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Quick answers about the PanaFlow HT
- Is the PanaFlow HT SIL certified? Yes. It is IEC 61508 certified, SIL2 as a single design and SIL3 capable in a redundant design.
- What temperatures can the PanaFlow HT handle? Process temperatures from -200 deg C to 600 deg C; transducer buffers cover -190 to 600 deg C in high-temperature versions.
- What sizes are standard? 3 in to 16 in (80 to 600 mm) standard, with sizes up to 72 in (1800 mm) available on request.
Documents and quotation
A manufacturer datasheet for the PanaFlow HT is available from Seven Star LLC on request and is attached to this listing where provided. To receive a quotation, send the RFQ with the part number PanaFlow HT, the quantity required and your delivery location, together with any hazardous area, range or configuration details from your project specification.
What to Send With Your Panametrics PanaFlow HT Enquiry
A fast, accurate quotation for the Panametrics PanaFlow HT depends on a few details. Please share the full part number, any suffix codes for options or approvals, the operating conditions at the installation point, and whether certificates of conformity or test reports must ship with the goods. It also helps to know if the unit is for planned maintenance, a shutdown, or an urgent breakdown, because that decides how we source and ship it. With that information we can check compatibility with your existing flowmeters, confirm availability, and reply with a clear delivery estimate for your site.
Datasheets & Documents
- Datasheet Panametrics PanaFlow HT SIL Ultrasonic Flow Meter for Liquids Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Panametrics is an American maker of ultrasonic flowmeters and moisture, oxygen and gas analysers. It was founded in 1960 and was based in Waltham, Massachusetts, when GE bought it in 2002. It later became a Baker Hughes business, and since 1 January 2026 it has belonged to Crane Company. Its long-running site in Shannon, Ireland, opened in 1973.
Seven Star LLC lists Panametrics flowmeters and analyzers for buyers in Oman: DigitalFlow gas and flare meters, clamp-on and portable liquid meters, and trace moisture analyzers for natural gas and process gases. We are an independent supplier, so each inquiry is checked against the manufacturer's order string before a quotation goes out.
Panametrics company profile
| Founded | 1960, Massachusetts, USA |
|---|---|
| Main sites | Billerica, Massachusetts, and Shannon, Ireland (since 1973) |
| Ownership | Crane Company since 1 January 2026; previously GE (from 2002) and Baker Hughes |
| Key technology | Transit-time ultrasonic flow measurement and aluminium oxide moisture sensing |
| Product families | TransPort PT900 portable and DigitalFlow fixed ultrasonic flowmeters for liquid, gas and flare gas, aluminium oxide moisture probes and hygrometers, Aurora laser moisture analysers, XMO2 oxygen and XMTC thermal conductivity transmitters |
Milestones
- 1960: Panametrics is founded.
- 1973: The Shannon, Ireland, site is established.
- 2002: GE acquires Panametrics.
- 2026: Crane Company completes its purchase of Baker Hughes' Precision Sensors & Instrumentation, including Panametrics.
Panametrics product families on this page
The listed items follow the manufacturer's own grouping:
- Gas and flare flow: DigitalFlow GF868 flare gas meter, GM868 and XGM868i gas flow transmitters
- Liquid flow: XMT1000 transmitter, AT600 AquaTrans clamp-on meter, TransPort PT900 portable meter
- Moisture: moisture.IQ multichannel analyzer, HygroPro II aluminum oxide transmitter, Aurora TDLAS analyzer for natural gas
Older units may carry GE Panametrics or GE Sensing on the nameplate. They belong to the same product lines, and the model string is read the same way.
Where Panametrics flowmeters and moisture analyzers are used
Flare meters report flared volumes on production sites, refineries and LNG plants. Clamp-on and portable ultrasonic meters check water, hydrocarbon liquid and utility lines without cutting the pipe. Aluminum oxide and TDLAS moisture analyzers watch dehydration units, gas pipelines, hydrogen and industrial gas streams. The manufacturer also names chemical processing, energy and water and wastewater among its markets, which matches what GCC operators ask us for.
Panametrics products we list
Ordering Panametrics equipment: what we need
A Panametrics model is a long configuration string, and the transducers or probes are ordered separately. Please send the full model and serial number of the electronics, the transducer or moisture probe part number, pipe size, schedule and material, fluid, pressure and temperature, flow range, hazardous area approval and output or protocol. For a flare meter add the flare gas composition range and velocity range. For moisture, give the dew point range and whether sample system components are required.
Facts checked against GE's 2002 acquisition release, Crane Company's January 2026 completion release and Irish press, October 2026.
FAQ
Questions about the Panametrics PanaFlow HT SIL Ultrasonic Flow Meter
Answers from our engineering team on installation, compatibility and integration.
01Is the PanaFlow HT SIL certified?
Yes. It is IEC 61508 certified, SIL2 as a single design and SIL3 capable in a redundant design.
02What temperatures can the PanaFlow HT handle?
Process temperatures from -200 deg C to 600 deg C; transducer buffers cover -190 to 600 deg C in high-temperature versions.
03What sizes are standard?
3 in to 16 in (80 to 600 mm) standard, with sizes up to 72 in (1800 mm) available on request.
04What accuracy does the PanaFlow HT offer?
Plus or minus 0.5 percent of reading across most of its velocity range, per the datasheet.
05What electronics does the PanaFlow HT use?
The XMT1000 transmitter with a six-button magnetic keypad and Modbus, HART or Foundation Fieldbus communication.