Brand:

Panametrics DigitalFlow XGS868i Steam Ultrasonic Flow Transmitter

Description

Panametrics XGS868i overview

The Panametrics DigitalFlow XGS868i is an ultrasonic flow transmitter for saturated and superheated steam. It measures the flow velocity and, with temperature and pressure inputs, its onboard computer calculates steam mass flow rate, which can be displayed locally or sent to a remote system through analog or digital links. The manufacturer notes its combination of rangeability, ease of installation, low maintenance and accuracy in a low-cost transmitter.

The XGS868i creates no pressure drop, has no moving parts or parts that foul or collect debris, and gives reliable, drift-free operation. All electronics are housed in a compact package installed at the measurement point, and the sealed metal wetted transducers supplied with the system resist erosion and thermal expansion stress. An optional two-channel model gives enhanced accuracy by measuring two paths on one pipe, or one path on each of two pipes.

Key features of the XGS868i

  • Measures mass flow of saturated and superheated steam.
  • No moving parts and no pressure drop.
  • Rangeability of 1500 to 1.
  • Nonobstructive measurement with tolerance to dirty streams.
  • Two-path measurement option.
  • Temperature and pressure inputs for mass flow calculation, with optional RTD inputs.
  • Optional HART, Modbus and RS485 digital interfaces.

Panametrics DigitalFlow XGS868i technical specifications

Parameter Value
Fluid types Saturated or superheated steam
Pipe sizes 2 in to 48 in (50 mm to 1200 mm) nominal bore
Pipe materials All metals
Accuracy (velocity) Plus or minus 1 to 2 percent of reading typical
Repeatability Plus or minus 0.2 to 0.5 percent of reading
Range (bidirectional) -150 to 150 ft/s (-46 to 46 m/s); rangeability 1500:1
Measurement parameters Mass flow, standard and actual flow, totalized flow and velocity
Power 100-240 VAC plus or minus 10 percent; optional 12 to 28 VDC; 20 W
Standard outputs Two isolated 0/4 to 20 mA, 600 ohm maximum, NAMUR NE043
Enclosure Epoxy-coated aluminum Type 4X IP66 Class I Division 1 Groups B, C, D; flameproof II 2 GD EEx d IIC T5
Operating temperature (electronics) -40 to 140 deg F (-40 to 60 deg C)
Wetted transducer temperature -50 to 150 deg C standard; optional -190 to 450 deg C overall
Wetted transducer pressure 0 to 2700 psig (187 bar) standard; optional 3480 psig (240 bar)
Transducer material Titanium standard; Monel or Hastelloy optional

Mounting is by flowcell or cold tap, with flanged and compression fittings. Accuracy depends on pipe size and on one-path or two-path measurement.

Typical applications in Oman and the GCC

Steam mass flow is central to boiler house balance, process heat allocation, turbine steam and utility billing. In Oman and the GCC the XGS868i can be applied on header and branch lines of refineries, petrochemical plants, power and desalination stations and large industrial sites where an orifice plate adds pressure loss and maintenance burden.

Selection and compatibility notes

Provide pipe size and schedule, steam pressure and temperature range and whether the steam is saturated or superheated. Choose transducer material and rating for temperature and pressure, add RTD or 4 to 20 mA inputs for temperature and pressure compensation, and select the relay, pulse and communication options. A preamplifier is available for long cable runs.

Steam metering depends on how well the measurement point represents the line. Choose a straight section away from valves and elbows, avoid locations where condensate can collect, and confirm the line is fully pressurized when the meter is commissioned. The XGS868i accepts temperature and pressure signals so that mass flow can be computed for both saturated and superheated conditions.

Ask your process engineers for the normal and extreme steam conditions rather than design conditions alone, because the transducer rating and the accuracy expectations are tied to the real operating range. Units, totalizer scaling and alarm relay settings should be agreed with the energy management team before shipment.

Installation and commissioning

Install wetted transducers in a flowcell or cold tap using the datasheet pipe and straight-run guidance, with typically 20 diameters upstream and 10 downstream. Use RG62 AU coaxial cable or the type specified for the transducer, up to 1000 ft where needed, and connect temperature and pressure signals for mass flow calculation.

Maintenance and service life

The meter needs little attention. Check transducer signal quality, verify the pressure and temperature inputs during plant shutdown surveys and record diagnostics after commissioning to compare later.

Related products and ordering notes

For other utility flow duties see the XGM868i gas and XMT868i liquid transmitters. For an XGS868i RFQ please state pipe size, steam conditions, transducer and flowcell needs, I/O and certification. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Quick answers about the XGS868i

  • What fluids can the XGS868i measure? It measures saturated and superheated steam and calculates mass flow from velocity plus temperature and pressure inputs.
  • What pipe sizes does the XGS868i cover? Pipes from 2 in to 48 in (50 mm to 1200 mm) nominal bore, all metals.
  • What accuracy does the XGS868i claim? Typically 1 to 2 percent of reading for velocity, with 0.5 percent achievable with process calibration, and repeatability of 0.2 to 0.5 percent.

Documents and quotation

A manufacturer datasheet for the XGS868i is available from Seven Star LLC on request and is attached to this listing where provided. To receive a quotation, send the RFQ with the part number XGS868i, the quantity required and your delivery location, together with any hazardous area, range or configuration details from your project specification.

Ordering Checklist for Panametrics DigitalFlow XGS868i

Before you request a quotation for the Panametrics DigitalFlow XGS868i, confirm the complete order code shown on the nameplate of the unit you are replacing, the supply voltage, and the process or signal ranges your system expects. If you are upgrading rather than replacing like for like, tell us the existing make and model so the mounting, wiring and connection details can be checked against the flowmeters you already run. For multi-unit orders, list the quantity per site and the required delivery location in Oman or the wider GCC, so packing, documentation and lead time can be confirmed in one quotation instead of several follow-up emails.

Other Models in the Panametrics Digitalflow Range

Seven Star LLC supplies models from the Panametrics Digitalflow range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Panametrics DigitalFlow XMT868i Liquid Ultrasonic Flow TransmitterUltrasonic FlowmetersView details
Panametrics DigitalFlow XGS868i Steam Ultrasonic Flow TransmitterUltrasonic FlowmetersYou are viewing this model
Panametrics DigitalFlow GC868 Clamp-On Gas Ultrasonic FlowmeterUltrasonic FlowmetersView details
Panametrics DigitalFlow DF868 Liquid Ultrasonic FlowmeterUltrasonic FlowmetersView details
Datasheets & Documents
  • PDF Datasheet Panametrics DigitalFlow XGS868i Steam Ultrasonic Flow Transmitter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Panametrics is an American maker of ultrasonic flowmeters and moisture, oxygen and gas analysers. It was founded in 1960 and was based in Waltham, Massachusetts, when GE bought it in 2002. It later became a Baker Hughes business, and since 1 January 2026 it has belonged to Crane Company. Its long-running site in Shannon, Ireland, opened in 1973.

Seven Star LLC lists Panametrics flowmeters and analyzers for buyers in Oman: DigitalFlow gas and flare meters, clamp-on and portable liquid meters, and trace moisture analyzers for natural gas and process gases. We are an independent supplier, so each inquiry is checked against the manufacturer's order string before a quotation goes out.

Panametrics company profile

Founded 1960, Massachusetts, USA
Main sites Billerica, Massachusetts, and Shannon, Ireland (since 1973)
Ownership Crane Company since 1 January 2026; previously GE (from 2002) and Baker Hughes
Key technology Transit-time ultrasonic flow measurement and aluminium oxide moisture sensing
Product families TransPort PT900 portable and DigitalFlow fixed ultrasonic flowmeters for liquid, gas and flare gas, aluminium oxide moisture probes and hygrometers, Aurora laser moisture analysers, XMO2 oxygen and XMTC thermal conductivity transmitters

Milestones

  • 1960: Panametrics is founded.
  • 1973: The Shannon, Ireland, site is established.
  • 2002: GE acquires Panametrics.
  • 2026: Crane Company completes its purchase of Baker Hughes' Precision Sensors & Instrumentation, including Panametrics.

Panametrics product families on this page

The listed items follow the manufacturer's own grouping:

  • Gas and flare flow: DigitalFlow GF868 flare gas meter, GM868 and XGM868i gas flow transmitters
  • Liquid flow: XMT1000 transmitter, AT600 AquaTrans clamp-on meter, TransPort PT900 portable meter
  • Moisture: moisture.IQ multichannel analyzer, HygroPro II aluminum oxide transmitter, Aurora TDLAS analyzer for natural gas

Older units may carry GE Panametrics or GE Sensing on the nameplate. They belong to the same product lines, and the model string is read the same way.

Where Panametrics flowmeters and moisture analyzers are used

Flare meters report flared volumes on production sites, refineries and LNG plants. Clamp-on and portable ultrasonic meters check water, hydrocarbon liquid and utility lines without cutting the pipe. Aluminum oxide and TDLAS moisture analyzers watch dehydration units, gas pipelines, hydrogen and industrial gas streams. The manufacturer also names chemical processing, energy and water and wastewater among its markets, which matches what GCC operators ask us for.

Panametrics products we list

Family Examples
Flowmeters AT600 AquaTrans Clamp-On Ultrasonic Wate…, DigitalFlow GM868 General-Purpose Gas Ul…, GF868 DigitalFlow Flare Gas Ultrasonic F…, PT900 TransPort Portable Ultrasonic Flow…, XGM868i DigitalFlow Gas Ultrasonic Flow…, XMT1000 Liquid Flow Ultrasonic Transmitter
Gas Analyzer Systems Aurora TDLAS Moisture Analyzer for Natur…, HygroPro II Aluminum Oxide Moisture Tran…, moisture.IQ Multichannel Trace Moisture…

Ordering Panametrics equipment: what we need

A Panametrics model is a long configuration string, and the transducers or probes are ordered separately. Please send the full model and serial number of the electronics, the transducer or moisture probe part number, pipe size, schedule and material, fluid, pressure and temperature, flow range, hazardous area approval and output or protocol. For a flare meter add the flare gas composition range and velocity range. For moisture, give the dew point range and whether sample system components are required.

Facts checked against GE's 2002 acquisition release, Crane Company's January 2026 completion release and Irish press, October 2026.

FAQ

Questions about the Panametrics DigitalFlow XGS868i Steam Ultrasonic

Answers from our engineering team on installation, compatibility and integration.

01What fluids can the XGS868i measure?
It measures saturated and superheated steam and calculates mass flow from velocity plus temperature and pressure inputs.
02What pipe sizes does the XGS868i cover?
Pipes from 2 in to 48 in (50 mm to 1200 mm) nominal bore, all metals.
03What accuracy does the XGS868i claim?
Typically 1 to 2 percent of reading for velocity, with 0.5 percent achievable with process calibration, and repeatability of 0.2 to 0.5 percent.
04What is the pressure rating of the wetted transducers?
Standard 0 to 2700 psig (187 bar) and optionally up to 3480 psig (240 bar).
05Can the XGS868i use RTD inputs?
Yes. Optional boards provide two or four isolated three-wire RTD inputs from -100 to 350 deg C.