Brand:

Alicat L-100CCM Liquid Flow Meter 100 CCM

Description

The Alicat L-100CCM is a volumetric liquid flow meter with a full scale of 100 cubic centimetres per minute. In the range-specific table of the L-Series sheet, sizes from 2 to 500 ccm share a 2.0 PSID pressure drop with water at full scale and 1/8 inch NPT female ports.

Small liquid flows with a display and a digital bus

The L-Series measures liquid flow with a laminar flow element and the same interactive display used across Alicat instruments, showing flow, temperature and pressure together. Volumetric accuracy is 2 % of full scale with 0.2 % of full scale repeatability, over a flow range of 2 to 100 % of full scale, and the sensor responds in under 1 ms.

Operating pressure is 100 PSIG, so the meter suits low-pressure dosing, coolant, sampling and laboratory circuits rather than high-pressure hydraulics. A tare before use removes the zero offset for the liquid in your line.

Key features as printed in the datasheet

  • Accuracy 2 % of full scale; repeatability (2 sigma) 0.2 % of full scale.
  • Pressure accuracy 0.5 % of full scale; operating pressure 100 PSIG.
  • Wetted materials 316L and 303 stainless steel with FKM elastomers; EPDM or FFKM optional.
  • Mounting orientation sensitivity: none.
  • Portable LB version adds a battery and Micro-USB communication.

Technical specification

Performance data (L-Series sheet)

Parameter Specification
Full scale 100 ccm
Volumetric flow accuracy 2 % of full scale (after tare, includes repeatability and linearity)
Repeatability (2 sigma) 0.2 % of full scale
Flow measurement range 2 to 100 % of full scale
Pressure accuracy 0.5 % of full scale
Operating pressure 100 PSIG
Temperature sensitivity 0.02 % of full scale per degC from 25 degC
Temperature accuracy / range 0.75 degC / -10 to 60 degC
Totalizer volume uncertainty 0.1 % of reading additional
Sensor / indication response under 1 ms / under 10 ms

Mechanical and electrical data

Parameter Specification
Pressure drop at full scale 2.0 PSID with water (venting to atmosphere)
Process connection 1/8 inch NPT female
Dimensions / weight 4.658 x 2.375 x 1.050 in (118.3 x 60.3 x 26.7 mm) / approx. 0.8 lb (0.4 kg)
Wetted materials 316L, 303 stainless steel and FKM elastomers
Maximum pressure 200 PSIG common mode; 75 PSI differential
Ingress protection IP40
Digital output RS-232 Serial and Modbus RTU as default; RS-485 serial and Modbus RTU, Modbus TCP/IP, DeviceNet, EtherCAT, EtherNet/IP, PROFINET, PROFIBUS and IO-Link as options
Analog output 4-20 mA, 0-5 Vdc, 1-5 Vdc, 0-10 Vdc; 1 kHz update, 0.1 % of full scale additional uncertainty
Power 0-5 V output 9-28 Vdc, 40 mA; 0-10 V 12-28 Vdc, 40 mA; 4-20 mA 12-28 Vdc, 80 mA

Selection and ordering guide

Alicat lists L-Series sizes from 0.5 ccm to 10 lpm; the 100 ccm size sits in the 2 to 500 ccm group that shares 1/8 inch NPT ports and mounting holes. The LS variant uses FFKM elastomers as standard for harsher fluids, and the LB variant is the battery-powered portable.

State the liquid, the viscosity, the line pressure and the communication option when you ask for a quotation, because the meter is calibrated for the fluid you name.

Because the meter reads volumetric flow, the indicated value depends on the liquid being the one it was set up for, and a change in viscosity or temperature shifts the result slightly; the sheet allows for this with its temperature sensitivity figure of 0.02 % of full scale per degC. Plan a loop that keeps the liquid within the -10 to 60 degC range, avoids dry running and lets you tare when the line is full and still. Where several L-Series sizes are installed, the 100 ccm unit is the same body as the 2 to 500 ccm group, so spare connectors and mounting hardware are interchangeable across that group.

Installation and operation notes

The Alicat L-Series manual calls for a clean, bubble-free liquid stream and a filter upstream of the meter; trapped gas will upset the reading. Mount with the flow arrow matching the line direction and purge air before taring.

Check that thermal expansion cannot trap liquid and raise pressure above the 200 PSIG damage limit, and tare only with the meter full of static liquid.

Applications in Oman and the GCC

A 100 ccm liquid meter fits reagent dosing, coolant loops on lasers and test benches, additive injection, fuel-cell water management and laboratory sampling. Verify chemical compatibility with 316L, 303 stainless steel and FKM before use with solvents or aggressive fluids.

Compatible accessories and related items

For gas service see the MC-100SLPM controller and BM-100SCCM compact meter on this site; for pressure see the P-100PSIG meter.

Frequently asked questions

What does the L-100CCM measure?

Volumetric liquid flow up to 100 ccm full scale, with 2 % of full scale accuracy.

What is the pressure drop?

2.0 PSID with water at full scale.

What is the maximum operating pressure?

100 PSIG, with damage possible above 200 PSIG common mode.

Which wetted materials are used?

316L and 303 stainless steel with FKM elastomers; EPDM and FFKM are optional.

Is Seven Star LLC an ALICAT distributor?

No, we are an independent supplier in Muscat and supply ALICAT items on request rather than acting as a ALICAT channel partner.

Documents and quotation

For quotation, send your required quantity and destination. The ALICAT datasheet for L-100CCM is provided below the description on this page. Seven Star LLC works as an independent supplier from Muscat. Please compare code, ratings and approvals with the document before you place an order; see also the category listing.

Datasheets & Documents
  • PDF Datasheet Alicat L-Series liquid flow meter specification sheet DOC-SPECS-L, rev 1 March 2026 (PDF) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

ALICAT Scientific is a flow and pressure instrument maker based in Tucson, Arizona. The company states that it is built on the principle that flow is caused by a difference in pressure, which led to its laminar differential-pressure mass flow technology, and that it has been part of the Halma Environmental and Analysis Sector since 2010.

Mass flow, liquid flow and pressure instruments

The ALICAT range covers gas mass flow meters and controllers, liquid flow meters, pressure meters and pressure controllers, with intrinsically safe IS-Max versions and compact BASIS models for OEM use. Most instruments store 98 gases, show flow, pressure and temperature on an interactive display and offer Modbus RTU and industrial fieldbus options.

Typical industries

ALICAT lists calibration and metrology, gas chromatography, semiconductor thin film deposition, leak testing, hydrogen, bioreactors and oil and gas research laboratories among its industries. Seven Star LLC quotes ALICAT instruments in Oman and the GCC with the official specification sheet for each item.

Frequently Asked Questions

What does the L-100CCM measure?
Volumetric liquid flow up to 100 ccm full scale, with 2 % of full scale accuracy.
What is the pressure drop?
2.0 PSID with water at full scale.
What is the maximum operating pressure?
100 PSIG, with damage possible above 200 PSIG common mode.
Which wetted materials are used?
316L and 303 stainless steel with FKM elastomers; EPDM and FFKM are optional.
Is Seven Star LLC an ALICAT distributor?
No, we are an independent supplier in Muscat and supply ALICAT items on request rather than acting as a ALICAT channel partner.