Brand: KELLER
KELLER Series 26Y Level Probe 4-20 mA 0.1 to 10 bar
Description
KELLER Series 26Y is a high-accuracy piezoresistive level probe, a submersible 4…20 mA transmitter that measures hydrostatic pressure from 0…0.1 to 0…10 bar. The AISI 316L body is 21 mm in diameter and about 73 mm long, weighs about 60 g without cable, and the cable gland is rated IP68.
Hydrostatic level from a probe hanging on its own cable
The datasheet lists hydrostatic pressure measurement, groundwater and surface-water level, and fill-level measurement in water and fuel tanks as typical uses. The probe is compensated over 0…50 degC and KELLER claims many years of maintenance-free operation.
Ranges are given in bar and metres of water column, and the analog interface can be scaled to other units. Accuracy is at most 0.25 %FS above 0.3 bar, 0.5 %FS from 0.15 to 0.3 bar and 1.0 %FS from 0.1 to 0.15 bar, with a total error band of 0.5 %FS above 2 bar and 1.0 %FS from 0.3 to 2 bar at 0…50 degC.
Key features as printed in the datasheet
- 2-wire 4…20 mA, supply 8…32 VDC.
- Standard shock voltage protection (50 A line-line, 200 A line-case, 8/20 us); optional lightning protection to 10 kA.
- Cable sheaths for water (PE or polyolefin) and for fuels (TPE-E); lengths 5, 10, 15, 25 or 40 m.
- Intrinsically safe 26Y-Ei version available for explosive atmospheres.
- Medium temperature -20…85 degC.
Technical specification
Performance and electrical data
| Parameter | Specification |
|---|---|
| Pressure ranges | 0…0.1 to 0…10 bar (relative PR, absolute PAA) |
| Accuracy at room temperature | max. 0.25 %FS above 0.3 bar; 0.5 %FS 0.15…0.3 bar; 1.0 %FS 0.1…0.15 bar |
| Total error band 0…50 degC | 0.5 %FS (2…10 bar); 1.0 %FS (0.3…2 bar); +/- 3 mbar (0.1…0.3 bar) |
| Long-term stability | max. 0.2 %FS per year above 2 bar; 4 mbar at 2 bar and below |
| Position dependency | max. 1.5 mbar |
| Output / supply | 4…20 mA (3.2…22.3 mA limits) / 8…32 VDC; 26Y-Ei 10…30 VDC |
| Load | below (U – 8 V)/25 mA; 26Y-Ei below (U – 10 V)/25 mA |
| Limiting frequency / start-up | 1 kHz / below 5 ms |
| Insulation GND-case | above 10 MOhm at 200 VDC |
Mechanical and environmental data
| Parameter | Specification |
|---|---|
| Housing material | AISI 316L; end cap POM |
| Seals | FKM internal and cable-gland seals |
| Oil filling | Silicone oil |
| Pressure connection | None (end cap), optional G1/4 |
| Dimensions / weight | dia 21 mm x approx. 73 mm; approx. 60 g without cable |
| Cable | Water: PR polyethylene dia 5.8 mm with capillary, PAA polyolefin; fuel: TPE-E |
| Medium / ambient / storage temperature | -20…85 degC each; no icing |
| Ingress protection | IP68 cable gland |
| Vibration / shock | 10 g, 10…2000 Hz / 50 g, 6 ms |
| Explosion protection | 26Y-Ei intrinsically safe version; conditions for safe use in the operating instructions |
Selection and ordering guide
Choose the range from the maximum depth: the table gives the water column in metres beside each bar range, and PAA 0.8…2 bar ranges need a special measuring range for sites above 2000 m. Select PR (vented, with capillary in the cable) for open tanks and wells, or PAA where the cable cannot be vented.
Pick the cable sheath for the liquid (water or fuel) and length (5 to 40 m standard). Specify the optional G1/4 connection if the probe will be fixed instead of suspended, and the lightning-protection option for long outdoor cable runs.
Installation and operation notes
Since the cable carries the reference capillary for PR versions, keep the cable end in a dry terminal box and do not kink or flood it. The diaphragm sits recessed behind the end cap, marked M in the drawing, so take care not to damage it during handling.
Mount the probe vertically for the stated 1.5 mbar position dependency, and select the fuel sheath where hydrocarbons are present.
Applications in Oman and the GCC
In the Gulf, level probes of this class serve water tanks, wells and boreholes, stormwater and wastewater sumps, and fuel-storage tanks. The 85 degC medium limit and the water or fuel cable choice should be checked against each application, and the Ei version is the route for classified areas.
Compatible accessories and related items
Related KELLER probes include Series 26X (RS485 and analog), 36XS, 36XiW and the digital Series 36XW listed on this site. Before ordering, confirm the maximum depth, cable sheath, cable length and any lightning-protection option with the datasheet, since each probe is made to the specified cable length.
Frequently asked questions
What does the 26Y measure?
Hydrostatic pressure from 0…0.1 to 0…10 bar, which is converted to liquid level, with a 4…20 mA output.
Can it be used in fuel tanks?
KELLER offers a TPE-E cable sheath for fuel applications; the 26Y-Ei is the intrinsically safe version.
What cable lengths are standard?
5, 10, 15, 25 and 40 m, others on request.
What protection class applies?
IP68 at the cable gland.
Is Seven Star LLC a KELLER distributor?
No, we are an independent supplier in Muscat and supply KELLER items on request rather than acting as a KELLER channel partner.
Documents and quotation
For quotation, send your required quantity and destination. The KELLER datasheet for 26Y is provided below the description on this page. Seven Star LLC works as an independent supplier from Muscat. Please compare code, ratings and approvals with the document before you place an order; see also the category listing.
Datasheets & Documents
- Datasheet KELLER Series 26Y / 26Y-Ei datasheet (PDF) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
KELLER is a Swiss manufacturer of piezoresistive pressure sensors and transmitters, founded in 1974 in Winterthur by physicist Hannes W. Keller, who had co-invented the integrated silicon measuring cell in 1966. Its breakthrough came in 1977 with an order for 1,000 OEM measuring cells. KELLER is family-run, led by Tobias and Mike Keller since 2019.
KELLER company profile
| Founded | 1974, Winterthur, Switzerland, by Hannes W. Keller |
|---|---|
| Headquarters | Winterthur, Switzerland |
| Ownership | Keller family; led by Tobias and Mike Keller since 2019 |
| Technology | Piezoresistive silicon pressure measuring cells |
| Product families | Series 21, 23 and 33X pressure transmitters, OEM pressure sensors and measuring cells, LEO digital manometers, DCX and ADT level dataloggers, level probes, calibrators |
Milestones
- 1966: Hannes W. Keller co-invents the integrated silicon measuring cell.
- 1974: KELLER is founded in Winterthur.
- 1977: A 1,000-cell OEM order brings the breakthrough.
- 2024: KELLER marks 50 years.
Pressure transmitters and level probes
The KELLER range covers standard and front-flush pressure transmitters, differential and low-pressure transmitters, submersible level probes, digital pressure gauges and data loggers. Many X-line devices combine RS485 Modbus RTU with an analog output, and intrinsically safe or increased-safety versions are offered for hazardous areas.
Typical industries
KELLER lists oil and gas, water and environment, HVAC, chemistry, food and pharma, and raw material extraction among its industries. Seven Star LLC quotes KELLER transmitters and level probes in Oman and the GCC with the official datasheet for each item.
KELLER products we list
Facts checked against KELLER's own 50th anniversary release (keller-druck.com), October 2026.
Related products
Frequently Asked Questions
Hydrostatic pressure from 0...0.1 to 0...10 bar, which is converted to liquid level, with a 4...20 mA output.
KELLER offers a TPE-E cable sheath for fuel applications; the 26Y-Ei is the intrinsically safe version.
5, 10, 15, 25 and 40 m, others on request.
IP68 at the cable gland.
No, we are an independent supplier in Muscat and supply KELLER items on request rather than acting as a KELLER channel partner.

Reviews