Brand:

SEKO BL095020 Double Impeller Side Channel Blower 15-25 kW

Description

The SEKO BL 095 020 is a double-impeller, single-stage side channel blower with a 5 inch connection, built for continuous duty as either an exhaust (vacuum) or compression blower. It is a large-frame unit: 15, 20 or 25 kW at 50 Hz, airflow of 2050 m3/h (2480 m3/h at 60 Hz), vacuum up to -310 mbar and pressure up to 280 mbar.

It is the blower SEKO’s ring-blower range offers for larger aeration and process-air jobs, and it ships as three order codes: BL09502015000, BL09502020000 and BL09502025000.

A high-flow ring blower for aeration and vacuum duty

Side channel blowers work on the lateral duct principle: the impeller sits directly on the motor shaft and moves gas around a ring channel, building pressure or vacuum without oil in the air stream. All rotating parts are dynamically balanced and the housing is full die-cast aluminium. The BL 095 020 is used on wastewater aeration, where it feeds diffusers in aeration tanks and sludge holding tanks, on pneumatic conveying and vacuum lifting, and on large drying and degassing systems that need a steady, oil-free air supply.

Features printed on the datasheet

  • Lateral channel (side channel) principle; works as exhaust or compression fan, designed for continuous service
  • Full die-cast aluminium construction
  • Double impeller, single stage, 5 inch connection
  • Data given for gas at 15 C inlet, normal density 1.23 kg/m3, absolute pressure 1023 mbar, tolerance plus or minus 10 percent
  • Impeller assembled directly on the motor shaft; rotating parts dynamically balanced

Technical specification

Parameter Specification
Order codes BL09502015000 (15 kW), BL09502020000 (20 kW), BL09502025000 (25 kW)
Frequency 50 Hz and 60 Hz versions
Maximum airflow 2050 m3/h at 50 Hz; 2480 m3/h at 60 Hz
Test gas condition 15 C, 1.23 kg/m3, 1023 mbar absolute, tolerance 10 percent
Connection 5 inch
Construction Full die-cast aluminium, impeller on motor shaft
Flange fixing (drawing) 490 mm circle, M12x30, holes at 0, 120 and 240 degrees
Model (50 Hz) Power Voltage delta / star Rated current Vacuum mbar Compressor mbar Noise dB(A) Weight kg
BL09502015000 15 kW 345-415 / 600-720 V 35.0 / 20.0 A -160 170 75 220
BL09502020000 20 kW 345-415 / 600-720 V 40.0 / 23.0 A -250 230 75 230
BL09502025000 25 kW 345-415 / 600-720 V 52.0 / 30.0 A -310 280 75 235

At 60 Hz the datasheet lists 17.5, 23 and 29 kW with 380-480 V delta and 660-720 V star, 2480 m3/h, vacuum of -120, -190 and -270 mbar, pressure of 110, 180 and 230 mbar, and noise of 84 dB(A).

Selecting between the three codes

Airflow is the same for all three codes, so the choice is pressure. The 15 kW unit reaches -160 mbar vacuum or 170 mbar pressure, the 20 kW unit -250 or 230 mbar, and the 25 kW unit -310 or 280 mbar. For aeration the pressure needed is set by the water depth over the diffusers plus pipe and filter losses, so size from the highest operating point rather than the average. Order by the full code including frequency, since the same frame has separate 50 and 60 Hz entries.

Installation notes

Mount on the supplied feet with anti-vibration pins (BLAV12), connect with a flexible sleeve and hose clips (BLSH125) and fit a pressure or vacuum gauge (BLMN06306 or BLVG06306). A safety valve (BLSV100AL02 or BLSV100AL24 with kit BLKS125100C) protects against overpressure, and an inlet cartridge filter (BLCF125PA007) protects the channel from dust, which matters in dusty Gulf locations. Blowers heat the air they compress, so the discharge pipe can be hot; provide guarding and ventilation.

Applications in GCC projects

Typical uses are municipal and industrial wastewater treatment plants, fish and aquaculture aeration, pneumatic conveying of powders, and vacuum holding on packaging and material-handling lines. In dusty or humid sites select the inlet filter grade by particle size.

Accessories listed in the datasheet

Item Code
Safety valve BLSV100AL02, BLSV100AL24
Safety valve installation kit BLKS125100C
In-line silencer BLIS125
Pressure gauge / vacuum gauge BLMN06306 / BLVG06306
Sleeve and hose clip kit BLSH125
Anti-vibration pins BLAV12
Cartridge filter BLCF125PA007

In-line paper, polyester and stainless steel filters, nipple and socket kits, final silencer, indoor filter and check valve are shown in the accessory list without a code for this frame; ask us for the current code. The wider range is under Compressors.

Selection and installation notes

A side channel blower is selected from the airflow, the vacuum or pressure, the duty cycle and the ambient temperature. Provide a clean intake with a filter, protect the motor against overload, keep the discharge line free of restrictions, fit a safety valve when the system could be blocked and leave clearance around the unit for cooling and for the noise level at the site.

Information needed for a quotation

Send the full model code, the quantity, the delivery location in Oman or the GCC, the intended use and any accessories needed, so that the complete package can be quoted together.

Documents and supply information

The manufacturer data sheet is attached to this page and should be read together with the project specification and the site risk assessment before a purchase is confirmed. Ratings, standards and dimensions are quoted as printed on that sheet. Lead time, stock position and certificates available with the shipment are confirmed in the quotation, and we supply to Oman and the wider GCC region for industrial, utility and building services projects.

Frequently asked questions

Can this blower produce both vacuum and pressure?
Yes. The datasheet says it can operate as either an exhaust or a compression fan, designed for continuous service.

What airflow does it deliver?
2050 m3/h at 50 Hz and 2480 m3/h at 60 Hz, at the standard test condition printed in the datasheet.

What are the three power ratings?
15, 20 and 25 kW at 50 Hz (17.5, 23 and 29 kW at 60 Hz), ordered as BL09502015000, BL09502020000 and BL09502025000.

What connection size is used?
A 5 inch connection.

Is the data guaranteed?
The datasheet gives a tolerance of plus or minus 10 percent at 15 C, 1.23 kg/m3 and 1023 mbar absolute.

Documents and quotation

To buy the SEKO BL095020 through Seven Star LLC, send an enquiry that states the order code, frequency, voltage, vacuum or pressure duty and the accessories needed. We act as an independent supplier in Muscat and reply with delivery time and terms. Please confirm the full order code with frequency and voltage against your duty before ordering. Read the SEKO BL 095 020 technical data sheet rev 3.0 first if you need to verify any figure.

Datasheets & Documents
  • PDF Datasheet SEKO BL 095 020 technical data sheet rev 3.0 Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

SEKO is an Italian manufacturer of chemical dosing and water treatment equipment, trading since 1976 from Rieti. Its range covers solenoid, motor-driven and peristaltic dosing pumps, controllers for treated water and blowers.

Seven Star LLC is an independent supplier in Muscat. We list SEKO pumps and controllers, each with the manufacturer datasheet, for water treatment and process users in Oman and the GCC.

SEKO product series

Solenoid dosing pumps include the Tekna TPG digital pump and the ATEX-marked Tekna for hazardous areas, both for 0.4 to 110 l/h. Motor-driven pumps include the Spring MS1 and compact MSV mechanical diaphragm pumps and the Spring PS1 plunger piston pump for higher pressures. The Kronos 65 is a peristaltic pump with a stepper motor.

The Kontrol 65 and Kontrol 102 controllers measure pH, ORP and conductivity and drive the dosing pumps, and the BL095020 and BL320002 are double impeller side channel blowers.

Where SEKO equipment is used

Chemical feed in cooling towers and boilers, effluent neutralisation, disinfection of potable and process water, swimming pools, aeration and hazardous-area dosing where the ATEX Tekna is specified.

Ordering SEKO pumps and controllers: what we need

Send the flow range, back pressure, chemical and concentration, pump head and seal material, supply voltage and, for pumps with a key code, the complete code as printed in the datasheet.

Frequently Asked Questions

Can this blower produce both vacuum and pressure?
Yes. The datasheet says it can operate as either an exhaust or a compression fan, designed for continuous service.
What airflow does it deliver?
2050 m3/h at 50 Hz and 2480 m3/h at 60 Hz, at the standard test condition printed in the datasheet.
What are the three power ratings?
15, 20 and 25 kW at 50 Hz (17.5, 23 and 29 kW at 60 Hz), ordered as BL09502015000, BL09502020000 and BL09502025000.
What connection size is used?
A 5 inch connection.
Is the data guaranteed?
The datasheet gives a tolerance of plus or minus 10 percent at 15 C, 1.23 kg/m3 and 1023 mbar absolute.