Brand: SEKO
SEKO Tekna TPG Digital Solenoid Dosing Pump 0.4-110 l/h
Description
The SEKO Tekna TPG is the digital-interface member of the Tekna solenoid dosing pump range. Where the AKL has a front knob and the APG a six-position switch, the TPG adds a display menu with proportional dosing, a timer, ppm dosing, statistics and a password, and it can talk MODBUS. It is a plastic-housed pump in IP65 fibreglass-reinforced polypropylene with a PVDF head and PTFE diaphragm.
Five sizes span 0.4 to 110 l/h and 0.1 to 20 bar, so the same electronics are reused from a laboratory-scale 0.4 l/h feed to a 110 l/h bulk chemical line.
A programmable metering pump for water and wastewater chemistry
The TPG is the Tekna to choose when the dosing rule is more than a fixed rate. It can follow a water meter pulse in division or multiplication mode (1:n or n:1), follow a 4-20 mA flow or analyser signal, or dose by ppm against a set flow. That makes it a natural fit for chlorine and hypochlorite dosing on potable-water booster stations, polymer and coagulant feed at wastewater plants, and biocide programmes on cooling towers, where the dose has to track flow. A remote ON-OFF input lets a level switch or PLC enable the pump, and statistics help plant staff see how much product has actually been pumped.
Features listed on the datasheet
- Constant flow rate, manually adjustable
- Timer function and ppm proportional dosing
- Operation from 100 to 240 Vac, 50/60 Hz
- Input ON-OFF (remote control) and communication via MODBUS protocol (see TPG-TPR-MODBUS variant)
- Statistics and password protection
- Manual priming valve, PVDF foot filter and injection valve in the standard kit
- Proportional flow from an external analogue (4-20 mA) or digital signal such as a water meter, 1:n or n:1
Technical specification
| Parameter | Specification |
|---|---|
| Series | Tekna TPG |
| Flow rate | 0.4 to 110 l/h |
| Maximum back pressure | up to 20 bar |
| Enclosure | PP reinforced with fibreglass, IP65 |
| Installation kit | Included (PVDF foot filter and injection valve, PVC suction tube, PE delivery tube) |
| Pump head | PVDF (PVC on request); SS316L option in the key code |
| Diaphragm | PTFE |
| Ambient limit | Up to 40 C, humidity up to 90 percent, not in sun or weather |
| Power supply | 100 to 240 Vac, 50/60 Hz |
| Stroke rate | 120 to 300 strokes/min |
| Priming | Manual priming valve |
| Drawing sheet | Datasheet rev 3.0, TD_Tekna_TPG_Series |
| Model | Smallest stroke volume cc | Max strokes/min | Flow versus pressure | Connections mm |
|---|---|---|---|---|
| TPG500N | 0.06 | 120 | 1.5 l/h at 6 bar up to 0.4 l/h at 20 bar | 4/6 and 4/7 |
| TPG600N | 0.35 | 120 | 7.0 l/h at 8 bar up to 2.5 l/h at 20 bar | 4/6 and 4/7 |
| TPG603N | 0.42 | 160 | 8.0 l/h at 2 bar down to 4.0 l/h at 12 bar | 4/6 |
| TPG800N | 0.39 | 300 | 18 l/h at 1 bar down to 7 l/h at 16 bar | 4/6 |
| TPG803N | 1.11 | 300 | 110 l/h at 0 bar, 62 l/h at 2 bar, 20 l/h at 5 bar | 8/12 |
Ordering with the TPG key code
The datasheet key code is TPG, size (500, 600, 603, 800 or 803), supply N, liquid end, installation kit, seals, optional and customisation. The liquid end letter H means PVDF, A is PVDF with automatic degassing (not for the 803 hydraulic) and I is SS316L. The installation kit can be H (PVDF), P (PVDF-T), X (with a 1.5 bar injection valve) or 0 (without kit, only for SS316L). Seals are 0 FKM-B, 1 EPDM, 2 PTFE, 3 FFKM (not on 803), B FPM for sizes 603 and 800, and C EPDM, a special seal for car-wash applications. The example in the datasheet is TPG 800 N H H 0 0 00.
Choose the size from the pressure you actually have at the injection point, not from the maximum flow alone. The 803 gives 110 l/h only at zero back pressure and falls to 20 l/h at 5 bar.
Installation, commissioning and care
Mount the pump on a wall or base bracket below the day tank where possible so the suction line stays flooded, use the manual priming valve until liquid is delivered, and set the mode with the selector menu. SEKO limits the site to 40 C and 90 percent humidity, away from sun and weather, so in outdoor Gulf installations a shaded cabinet is advisable. Pressure data were measured with the SEKO standard injection fitting.
Where it is used in the GCC
The TPG suits municipal and industrial water treatment: hypochlorite at reservoir inlets, pH correction on cooling-tower blowdown, antiscalant ahead of reverse-osmosis membranes at desalination and boiler-feed plants, and polymer dosing at sewage works. Because the housing is plastic and the head PVDF, it handles acids and hypochlorite better than metals, but it is not marked for hazardous areas; for those use the Tekna ATEX.
Accessories and neighbouring models
Related items are SEKO foot filters, injection valves, suction and delivery tubing and wall brackets. The same family includes the AKL and AKS (manual), APG (analogue proportional) and TCK (timer) pumps. More dosing equipment is listed under Pumps.
Frequently asked questions
What is the difference between TPG and APG?
The datasheet describes the TPG as the digital interface version of the APG, adding menu control, timer, ppm dosing, statistics and password.
What flow range does the TPG offer?
0.4 to 110 l/h at up to 20 bar, depending on whether size 500N, 600N, 603N, 800N or 803N is chosen.
Is an installation kit included?
Yes. The standard kit has a PVDF foot filter and injection valve, a PVC suction tube and a PE delivery tube.
Which liquid ends can be ordered?
PVDF (H), PVDF with automatic degassing (A, not for 803) or SS316L (I) per the key code.
What supply voltage does it use?
100 to 240 Vac, 50/60 Hz.
Documents and quotation
Looking for a quotation on the TEKNA TPG? We are an independent supplier, not the manufacturer, so stock and delivery time are confirmed enquiry by enquiry. Tell us the flow in l/h, back pressure, chemical, control mode and supply voltage. Please confirm size, liquid end and seals against your process data before ordering. Before you order, open the SEKO Tekna TPG technical data sheet rev 3.0 from the document box above.
Datasheets & Documents
- Datasheet SEKO Tekna TPG technical data sheet rev 3.0 Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
SEKO is an Italian manufacturer of chemical dosing and water treatment equipment, trading since 1976 from Rieti. Its range covers solenoid, motor-driven and peristaltic dosing pumps, controllers for treated water and blowers.
Seven Star LLC is an independent supplier in Muscat. We list SEKO pumps and controllers, each with the manufacturer datasheet, for water treatment and process users in Oman and the GCC.
SEKO product series
Solenoid dosing pumps include the Tekna TPG digital pump and the ATEX-marked Tekna for hazardous areas, both for 0.4 to 110 l/h. Motor-driven pumps include the Spring MS1 and compact MSV mechanical diaphragm pumps and the Spring PS1 plunger piston pump for higher pressures. The Kronos 65 is a peristaltic pump with a stepper motor.
The Kontrol 65 and Kontrol 102 controllers measure pH, ORP and conductivity and drive the dosing pumps, and the BL095020 and BL320002 are double impeller side channel blowers.
Where SEKO equipment is used
Chemical feed in cooling towers and boilers, effluent neutralisation, disinfection of potable and process water, swimming pools, aeration and hazardous-area dosing where the ATEX Tekna is specified.
Ordering SEKO pumps and controllers: what we need
Send the flow range, back pressure, chemical and concentration, pump head and seal material, supply voltage and, for pumps with a key code, the complete code as printed in the datasheet.
Browse SEKO products by category: Pumps.
Related products
Frequently Asked Questions
The datasheet describes the TPG as the digital interface version of the APG, adding menu control, timer, ppm dosing, statistics and password.
0.4 to 110 l/h at up to 20 bar, depending on whether size 500N, 600N, 603N, 800N or 803N is chosen.
Yes. The standard kit has a PVDF foot filter and injection valve, a PVC suction tube and a PE delivery tube.
PVDF (H), PVDF with automatic degassing (A, not for 803) or SS316L (I) per the key code.
100 to 240 Vac, 50/60 Hz.

Reviews
There are no reviews yet.