Brand:

ABB TU830V1 S800 I/O Extended Module Termination Unit

Description

The 3BSE013234R1 is the S800 I/O Extended Module Termination Unit TU830V1 from ABB. ABB’s product page describes it as an extended unit with 2 x 16 signal terminals. It hosts one S800 I/O module, offers 56 process connections and carries the fuses for transmitter supply, so it is the base used for analog inputs and for channels that need protected sensor power. Modules are listed under PLC and I/O cards, and the DI810/DO810 set is an example of modules that can sit on it.

Technical specifications

Parameter Specification
Type / article number TU830V1 / 3BSE013234R1
Unit class Extended module termination unit (MTU)
Connection Terminal block
Channels / voltage 16 channels, 50 V
Process connections 56
Mounting DIN rail, both directions, 55 C
Single or redundant I/O Single
Width 126 mm including connector, 120.5 mm edge to edge installed
Depth / height 64 mm including terminals / 110 mm
Weight 0.28 kg (0.6 lb)
Transmitter supply fusing On the extended MTU; TU830 maximum 1 A slow per group (from the AI810 data sheet)
Sensor power distribution Maximum 1 A per connection (AI810 data)
Compliance RoHS EN 50581:2012, WEEE Directive 2012/19/EU

Modules supported by the TU830V1

ABB lists the TU830V1 for analog inputs AI810, AI815, AI820, AI830, AI830A, AI835, AI835A, AI843 and AI845, analog outputs AO810, AO810V2, AO815, AO820, AO845 and AO845A, digital inputs DI810, DI811, DI814, DI818, DI830, DI831, DI840, DI880 and DI885, digital outputs DO810, DO814, DO815, DO818, DO840 and DO880, and the DP820 and DP840 pulse counters. That makes it the broadest base in the 50 V group, and the one specified when transmitter supply needs individual fusing.

Why choose the extended unit

The extended MTU is wider than the compact TU810V1, 126 mm against 64 mm, and lower at 110 mm against 170 mm, so panel layout changes. In return it provides more process connections and the fuse positions for transmitter supply, a feature the AI810 data sheet lists for transmitter supply. If only plain switching signals are wired, a compact unit can be enough. Check the keying code of the module being mounted, because the MTU keys prevent a wrong module from being inserted.

Installation and environment

The TU830V1 is rated for 55 C in both mounting directions according to the ABB outline, so unlike the compact TU810V1 it has no separate lower limit for vertical mounting. At 0.28 kg it weighs more than the 0.17 kg compact unit, and at 126 mm including connector it takes more rail width. S800 I/O is ABB’s distributed, modular process I/O system: it communicates with parent controllers over industry-standard field buses, and hot swap of modules and on-line reconfiguration are part of its design. ABB lists it for single, non-redundant I/O, and it meets RoHS (EN 50581:2012) and WEEE (2012/19/EU).

Planning the cabinet layout around the TU830V1

Because the extended termination unit is wider than a compact base, the rail plan should be drawn before the cabinet is built rather than after. Count the positions that will carry analog inputs or other channels needing fused transmitter supply, assign those to TU830V1 bases, and reserve the remaining rail length for modules that only need plain terminals. Leave room for wiring ducts on both sides of the rail, since 56 process connections on a single unit produce a dense bundle of field cores. Mark each base with its module type and keying code on the cabinet drawing, so that a technician replacing a module years later does not have to guess which card belongs in which position.

Wiring and commissioning checks

Before power is applied, check every field core against the loop drawing at the terminal block itself, not only at the marshalling side. Confirm that transmitter supply fuses are fitted in the positions the design calls for and that their rating follows the module data sheet rather than a habit carried over from another project. With the module removed, check that no unexpected field voltage is present on terminals intended for passive inputs. Once the module is inserted and recognised by the controller, step each channel through its range from the field side and record the reading on the commissioning sheet. A blown transmitter fuse usually shows up at this stage as a group of dead channels, which is far easier to trace before the plant is running than after.

Operating the unit in Omani equipment rooms

Many sites in Oman place I/O cabinets in local equipment rooms close to the process, where summer heat and fine dust are the main threats to electronics. The 55 C rating of the TU830V1 applies to the air around the unit, so the cabinet interior has to stay below that figure even when the room air conditioning is struggling. Filtered ventilation or a cooled enclosure, door seals in good condition and a routine of changing filters before the hot season all help. In coastal locations such as Sohar, Duqm or Sur, salt-laden air can attack terminal screws and fuse contacts over time, so keep cabinet doors closed, inspect terminals during planned shutdowns and retighten any connection that shows discolouration or corrosion.

Spares and maintenance routine

Since S800 I/O is designed for hot swap of modules, many I/O faults can be cleared by exchanging the module, but the termination unit itself carries the field wiring and is a slower job to replace. Keep spare transmitter supply fuses of the correct type with the cabinet, record which channels are fed through each fuse group, and include a visual check of the MTU terminals and keying in the annual maintenance plan. When a termination unit does have to be replaced, photograph the wiring first and label every core before it is disconnected.

Ordering and documents

Use the article number 3BSE013234R1. Please confirm the module type, signal voltage, fusing needs and wiring before ordering. The ABB outline linked here dated 2026-06-04 lists the whole MTU range; Seven Star LLC is an independent supplier in Muscat and quotes on request, with no price or stock shown on this page.

Datasheets & Documents
  • PDF Datasheet ABB data sheet I/O MTUs - S800 I/O, outline of module termination units (Freelance hardware selector, 2026-06-04) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

ABB, formed in 1988 and headquartered in Zurich, covers an unusually long stretch of a plant's equipment list, from the flowmeter and analyzer in the field to the drive, breaker and protection relay in the electrical room.

Seven Star LLC is an independent supplier serving Oman and the GCC. Our ABB listing concentrates on measurement and analytics: ABB flowmeters, liquid analysis sensors and systems, level and pressure instruments. It also includes valve actuators, low voltage circuit breakers, ABB drives, soft starters and protection relays.

ABB product families on this page

Flow measurement includes ABB electromagnetic, Coriolis, vortex and swirl meters, sold under names such as ProcessMaster, AquaMaster, CoriolisMaster and SwirlMaster. Liquid analysis covers pH, conductivity and dissolved oxygen sensors with their transmitters. SensyTemp TSP sensors handle temperature. On the electrical side the listing has ACS355 machinery drives, the ACS550 general purpose drive, the ACQ580 for water and wastewater and the ACS880-01 industrial drive, with fieldbus adapters such as the FPBA-01 for PROFIBUS DP. Protection and switching products include SACE Tmax XT molded case breakers, SACE Emax 2 air circuit breakers, PSR soft starters and the REM615 and RET615 relays.

Where ABB instruments and drives are used

Water and wastewater plants use the electromagnetic flowmeters, analyzers and ACQ580 drives together. Oil and gas, power and chemical plants specify the Coriolis and vortex meters, pressure and level transmitters and the 615 series relays for motor and transformer feeders. The drives run pumps, fans, conveyors and compressors in almost every industry.

Ordering ABB parts: what we need

For drives send the full type code from the rating label, for example ACS355-03E-05A6-4, plus the serial number if it is a replacement. For instruments send the complete order code, measuring span, process connection, wetted materials, output or protocol and the hazardous area approval. For breakers give frame size, rated current, breaking capacity, number of poles, trip unit and fixed or withdrawable version.

Frequently Asked Questions

What is 3BSE013234R1?
The ABB S800 I/O extended module termination unit TU830V1, 50 V, terminal block.
How many process connections does the TU830V1 have?
56 process connections according to the ABB outline.
What are the TU830V1 dimensions?
126 mm wide including connector (120.5 mm installed), 64 mm deep and 110 mm high.
Does it provide transmitter fusing?
Yes. The AI810 data sheet states fusing of the transmitter supply is on the extended MTU, TU830 maximum 1 A slow per group.
Which modules can it host?
Many S800 analog and digital modules, for example AI810, AI835, DI810, DO810 and DP840, as listed in the ABB outline.