Brand: Kamstrup
Kamstrup MULTICAL 21 flowIQ 2101 Compact Water Meter
Description
Ultrasonic water metering for apartments and small commercial supplies
The Kamstrup MULTICAL 21 and flowIQ 2101 is a hermetically closed compact static water meter for registering cold and hot water in households, apartment buildings and small commercial properties. Two ultrasonic transducers send sound with and against the flow, and the time difference gives velocity and volume, so there are no moving parts to wear. Kamstrup quotes a start flow of only 2 l/h for Q3 of 1.6 and 2.5 m³/h and 3.2 l/h for Q3 of 4.0 m³/h, and built-in leak monitoring down to 0.1 % of Q3. The meter also measures water and ambient temperature and logs minimum, mean and maximum values.
Technical specifications
| Parameter | Specification |
|---|---|
| Nominal flow Q3 | 1.6, 2.5 or 4.0 m³/h |
| Dynamic range Q3/Q1 | 100:1, 160:1 or 250:1 depending on type (for example Q3 1.6: Q1 10 or 16 l/h; Q3 2.5: Q1 10 or 25 l/h; Q3 4.0: Q1 16 or 40 l/h) |
| Max flow Q4 | 2.0, 3.1 and 5.0 m³/h respectively |
| Pressure loss at Q3 | 0.17 bar (Q3 1.6) and 0.40 bar (Q3 2.5 and 4.0) |
| Connections / length | G¾B x 110 or 170 mm; G1B x 105, 130 or 190 mm (170 mm versions only for selected markets) |
| Medium temperature | Cold 0.1 to 30 °C (T30) or 0.1 to 50 °C (T50); hot 0.1 to 70 °C (T70); T30/70 on M-Bus versions |
| Accuracy / class | OIML R49 accuracy class 2, sensitivity U0/D0, ambient class B and O; MID approval DK-0200-MI001-015 |
| MPE | ±5 % for Q1 ≤ Q < Q2; ±2 % for Q2 ≤ Q ≤ Q4 (up to 30 °C); ±3 % above 30 °C |
| Drinking water approvals | DVGW W 421, WRAS, ACS, Belgaqua, SCU, PZH, NNK |
| Pressure stage / protection | PN16; IP68; ambient 2 to 55 °C |
| Battery | 3.65 VDC, 1 C-cell lithium; up to 16 years (up to 8 years for M-Bus at battery temperature below 55 °C) |
| Wetted materials | Housing and pipe PPS 40 % glass fibre and PSU; reflectors stainless steel; strainer PES |
| Radio | Wireless M-Bus (16 or 96 s intervals) or Sigfox (daily, RC1 868 MHz, 14 dBm, class zero); wired M-Bus version available |
| Data storage | Daily registers for 460 days, monthly for 36 months, yearly for 10 years |
| Other approvals | ATEX 2014/34/EU, zone 2 |
Type number, cold or hot water and communication
The type number has the form 021-YY-C0x-8XX. The letter after C0 selects the size, flow range and thread length, from C0A (Q3 1.6 m³/h, G¾B x 110 mm) to C0P (Q3 4.0 m³/h, G1B x 190 mm). YY selects the communication package, XX is the country code assigned by Kamstrup, and the last block is 8XX for cold water and 7XX for hot water. Extension pipes are available as accessories so the meter can match existing installation lengths. Info codes on the display include LEAK, BURST, TAMPER, DRY and REVERSE, which help operators locate losses and fraud attempts.
Installation and where it fits
The meter can be installed horizontally or vertically independent of piping and installation conditions. The housing is moulded composite with a vacuum-sealed electronics chamber, so condensation between glass and display is avoided; the unit can only be opened by Kamstrup, and a broken seal ends its validity for billing. For larger bulk connections see the Kamstrup flowIQ 4200, and for another smart ultrasonic water meter the Kamstrup flowIQ 2200. More meters are listed under Flowmeters.
How the Kamstrup MULTICAL 21 works
Two ultrasonic transducers send sound pulses through the water, one with the flow and one against it. The pulse with the flow arrives first. The meter measures the time difference and calculates the velocity and the volume. With no moving parts there is nothing to wear. A battery in the meter powers the electronics and the radio.
Where the MULTICAL 21 is used
- Apartment buildings
- Households
- Small commercial properties
- Cold water supply lines
- Hot water lines up to 70 degrees C
Selection checklist for the MULTICAL 21
- Nominal flow Q3 of 1.6, 2.5 or 4.0 m3/h
- Dynamic range
- Thread size and length
- Cold or hot water
- Wireless M-Bus, Sigfox or wired M-Bus
- Battery life needed
- Pipe pressure of PN16
- Reading method
Installation, commissioning and maintenance notes for the MULTICAL 21
Flush the pipe before fitting the meter. Fit it with the arrow along the flow and with the seals in place. Keep the pipe full of water. Check the display and the leak monitor after start-up. Keep the radio free from metal covers.
Requesting a quotation for the Kamstrup MULTICAL 21
Please send the flow size, the thread, the communication and the quantity. Seven Star LLC serves industrial customers in Oman and the GCC and replies with a quotation based on the information provided.
MULTICAL 21 nominal flow
The nominal flow Q3 is 1.6, 2.5 or 4.0 m3/h.
MULTICAL 21 start flow
The start flow is 2 l/h for the two smaller sizes and 3.2 l/h for the largest.
MULTICAL 21 maximum flow
The maximum flow Q4 is 2.0, 3.1 and 5.0 m3/h.
MULTICAL 21 pressure stage
The meter is rated PN16 and IP68.
MULTICAL 21 medium temperature
Cold water types work to 30 or 50 degrees C and hot water types to 70 degrees C.
MULTICAL 21 battery
The battery is one C-cell lithium cell that lasts up to 16 years.
MULTICAL 21 radio
The radio is wireless M-Bus or Sigfox, and a wired M-Bus version is also made.
MULTICAL 21 data storage
It keeps daily registers for 460 days, monthly for 36 months and yearly for 10 years.
Meter records for the MULTICAL 21
Record the serial number, the first reading and the date of installation.
Choosing the right MULTICAL 21 type
Choose the dynamic range by the lowest flow the building must register accurately.
Documents and quotation
The Kamstrup data sheet for MULTICAL 21 and flowIQ 2101 is attached; note that it is dated June 2021, so check current approvals when you place an order. Please tell us Q3 and thread size, installation length, cold or hot water, communication (wireless M-Bus, Sigfox or wired M-Bus), reading method and the destination country, and we will prepare a quotation.
Datasheets & Documents
- Datasheet Kamstrup MULTICAL 21 and flowIQ 2101 Data Sheet (58101587_F1_GB-UAE_06.2021) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Ultrasonic measurement with no moving parts is the idea behind the flowIQ water meters and ultrasonic energy meters of Kamstrup. The Danish company, founded in 1946 in Skanderborg, makes meters for water, heat and cooling that are read remotely. Seven Star LLC lists the Kamstrup flowIQ water meters and the MULTICAL 403 energy meter, and supplies Kamstrup meters to utilities, district cooling operators and building owners in Oman and the GCC.
Kamstrup meter families on this page
The flowIQ 2200 is an ultrasonic smart water meter for residential, multi-unit and commercial connections. The flowIQ 4200 is the bulk water meter, made in five sizes from DN125 to DN300. The MULTICAL 403 is an ultrasonic thermal energy meter that can be supplied as a heat meter, a cooling meter or a combined heat and cooling meter, with a matched pair of temperature sensors and communication modules.
Ordering Kamstrup meters: what we need
Send the type number from the meter front if you are matching installed units. Otherwise give nominal flow and pipe size, connection type and meter length, heat or cooling service, where the flow sensor sits (supply or return pipe), the temperature sensor type and cable length, and the communication you need, for example wired M-Bus or a radio option.
Browse Kamstrup products by category: Flowmeters.
Related products
Frequently Asked Questions
According to the datasheet they are one meter platform. The version with Wired M-Bus is ordered under the name flowIQ 2101, and the Wireless M-Bus and Sigfox versions under MULTICAL 21.
Nominal flow Q3 is 1.6, 2.5 or 4.0 m3/h with G3/4B or G1B connections and lengths of 105 to 190 mm. Cold water is 0.1 to 30 °C (T30) or 0.1 to 50 °C (T50), and hot water is 0.1 to 70 °C (T70) or T30/70 on M-Bus versions.
By display or optical eye, or remotely. Wireless M-Bus radio packages transmit every 16 or 96 seconds and can be set for drive-by or fixed network, while the Sigfox version transmits daily. A wired M-Bus version is also offered.
The meter is IP68 type tested and hermetically sealed, and the datasheet describes pit installation and bathroom environments. Direct prolonged sunlight must be avoided.
No. Seven Star LLC is an independent industrial supplier in Muscat and is not a distributor or agent of Kamstrup. We check the type number against Kamstrup documentation before quoting.