Brand: Brooks Instrument
Brooks Instrument Quantim QMC Coriolis Mass Flow Controller
Description
Low-flow Coriolis control for liquids and gases in one compact unit
The QMC is the third-generation Quantim low-flow Coriolis mass flow meter and controller from Brooks Instrument for liquids and gases. It is compatible in fit, form and function with the second-generation QMB models, and adds a modern digital architecture for fast response, more simultaneous outputs and better diagnostics. The controller version (QMCC) integrates the sensor, a coplanar control valve and PID control; the meter version is the QMCM.
A Coriolis sensor measures mass flow directly, independent of fluid type and process variables, so the chemistry or conditions can change without recalibration. With a range of 0.001 to more than 27 kg/hr, the device reports mass flow, volume flow, density and temperature together with diagnostic values. A service port on a 2.5 mm jack and the free BEST (Brooks Expert Support Tool) software simplify setup and troubleshooting.
Technical specifications
| Parameter | Specification |
|---|---|
| Models | QMCC controller and QMCM meter, tube sizes 2, 3 and 4 |
| Nominal flow, controller, liquid | 0.15, 0.78 and 7.97 kg/hr (tube 2, 3, 4) |
| Nominal flow, meter, liquid | 0.19, 1.30 and 13.50 kg/hr |
| Nominal flow, controller, gas | 1051, 2955 and 24787 sccm |
| Nominal flow, meter, gas | 1432, 7207 and 53116 sccm |
| Maximum flow, liquid | 0.3, 1.4 and 16.0 kg/hr (controller); 0.38, 1.4 and 27.0 kg/hr (meter) |
| Minimum flow, liquid | 0.001, 0.010 and 0.100 kg/hr |
| Standard accuracy | Liquid 0.2% of rate; gas 0.5% of rate, or zero stability divided by flow if greater |
| Repeatability | +/-0.05% of rate or +/-[0.5 x (zero stability / flow rate) x 100]%, whichever is greater |
| Response time | Under 2 s (controller); under 0.5 s (meter), to 2% of final value |
| Turndown | 100:1 or down to minimum flow |
| Operating temperature | 0 to 60 C; device temperature accuracy +/-0.5 C |
| Differential pressure | Liquid 10 to 200 psi (0.69 to 13.8 bar); gas 10 to 150 psi (0.69 to 10.3 bar) |
| Maximum operating pressure | 500 psi (34.5 bar); optional 1500 psi (103 bar) |
| Density | Range 0 to 2.0 g/cc, accuracy +/-0.005 g/cc |
| Leak integrity (external) | Elastomer 1×10-9 atm cc/sec He; metal seal 1×10-10 |
| Wetted materials | 316L, 316L VAR, high-alloy ferritic stainless steel, 17-7PH |
| Seals | Viton, Buna, Kalrez or EPDM; metal seal option in stainless steel and nickel |
| Enclosure and weight | IP40 or IP66 polyurethane-painted aluminium; 2.4 kg (IP40) and 2.5 kg (IP66) |
| Outputs | RS485 S-Protocol; analog 0-20 mA, 4-20 mA, 0-5 Vdc or 0-10 Vdc for mass or volume flow, plus density or temperature |
| Power | +14 to 27 Vdc; controller up to 10.6 W, meter up to 3.7 W |
| Alarms | Mass flow, density, volumetric flow, temperature, slug flow, diagnostic failure, setpoint deviation, valve drive |
| Compliance | EMC 2014/30/EU EN 61326-1, RoHS 2011/65/EU and 2015/863 |
Using the QMC model code
Positions 1 to 4 select the QMCC controller or QMCM meter, position 5 the tube size and position 6 liquid or gas service. The valve is normally closed or absent for a meter, and the accuracy code gives 0.2 percent of rate for liquid, 0.5 percent for gas or 1.0 percent optional for gas. The enclosure code runs from IP40 with no area classification through IP66, UL recognised or listed Class 1 Division 2, ATEX Zone 2 and IECEx Zone 2 versions. Maximum pressure is 500 or 1500 psi, the tube is 316L stainless steel, and process connections include 5/16-24 UNF, tube compression from 1/16 inch to 1/4 inch and 6 mm, NPT female, VCR, VCO and 3.2 mm UPG, with metal seals available on VCR and UPG ports.
What to confirm before ordering
We need the fluid, minimum and maximum flow in mass units, inlet and outlet pressure, operating temperature, fitting, enclosure and area classification, signal type and seal material. The datasheet recommends additional upstream filtration for all installations and in-line filters of 1 or 10 micron on the smallest controller, and it notes that in-line filters are not recommended in moisture-sensitive applications. Units are purged to a dew point below minus 40 C before shipment.
How the Brooks QMC works
The fluid flows through a vibrating tube. The mass flow changes the motion of the tube, and the sensor measures that change directly. On the controller version, a coplanar control valve and PID control then hold the flow at the setpoint.
Where the QMC is used
- Low-flow liquid dosing
- Low-flow gas control
- Process lines where the fluid changes
- Replacement of second-generation QMB units
- Skid and laboratory systems
Selection checklist for the QMC
- Controller or meter version
- Liquid or gas
- Tube size
- Flow range
- Differential pressure
- Operating pressure
- Wetted materials
- Seal material
Installation, commissioning and maintenance notes for the QMC
Mount the unit where vibration is low and keep the line full of fluid. Connect power and the outputs, then use the service port and BEST software for setup. Zero the unit with no flow and check the diagnostic values at regular intervals.
Requesting a quotation for the Brooks QMC
Please send the fluid, the flow range, the pressure and the version needed. Seven Star LLC serves industrial customers in Oman and the GCC and replies with a quotation based on the information provided.
QMC generation
It is the third-generation Quantim low-flow Coriolis mass flow meter and controller.
QMC fluids
It is made for liquids and gases.
QMC compatibility
It is compatible in fit, form and function with the second-generation QMB models.
QMC digital architecture
A modern digital architecture gives fast response, more simultaneous outputs and better diagnostics.
QMC versions
The controller version is the QMCC and the meter version is the QMCM.
QMC controller parts
The QMCC integrates the sensor, a coplanar control valve and PID control.
QMC direct measurement
A Coriolis sensor measures mass flow directly, independent of fluid type and process variables.
QMC no recalibration
The chemistry or conditions can change without recalibration.
QMC flow range
The range is 0.001 to more than 27 kg/hr.
QMC reported values
It reports mass flow, volume flow, density and temperature with diagnostic values.
QMC service port
A service port on a 2.5 mm jack is provided.
QMC BEST software
The free BEST software simplifies setup and troubleshooting.
QMC tube sizes
Tube sizes are 2, 3 and 4.
QMC controller liquid flow
Nominal liquid flow on the controller is 0.15, 0.78 and 7.97 kg/hr.
QMC meter liquid flow
Nominal liquid flow on the meter is 0.19, 1.30 and 13.50 kg/hr.
QMC controller gas flow
Nominal gas flow on the controller is 1051, 2955 and 24787 sccm.
QMC meter gas flow
Nominal gas flow on the meter is 1432, 7207 and 53116 sccm.
QMC minimum liquid flow
The minimum liquid flow is 0.001, 0.010 and 0.100 kg/hr.
QMC response time
The controller responds in under 2 s and the meter in under 0.5 s.
QMC turndown
The turndown is 100:1 or down to the minimum flow.
QMC operating temperature
The operating temperature is 0 to 60 degrees C.
QMC differential pressure
Liquid needs 10 to 200 psi and gas 10 to 150 psi.
QMC maximum pressure
The maximum operating pressure is 500 psi, with 1500 psi optional.
QMC density range
The density range is 0 to 2.0 g/cc.
QMC wetted materials
Wetted parts are 316L, high-alloy ferritic stainless steel and 17-7PH.
Flow records for the QMC
Record the fluid, the setpoint and the date of each zero check.
Choosing the right QMC tube size
Choose the tube size from the flow range and the pressure drop the line allows.
Documents and quotation
The manufacturer datasheet (8 pages) is attached to this page as a download. For a quotation, send the full model code and the process data to Seven Star LLC in Muscat; browse more instruments in the Flowmeters category. We supply this item as an independent supplier, so please confirm availability and delivery with us.
Datasheets & Documents
- Datasheet Brooks Instrument Quantim QMC Series datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Brooks Instrument makes mass flow controllers, flowmeters and pressure and vacuum instruments for gases and liquids. The industrial chemist Stephen A. Brooks started the business in 1946 as the Brooks Rotameter Company near Philadelphia, building variable area flowmeters. After many years as part of Emerson, Brooks was sold to American Industrial Partners at the end of 2007 and has been a division of Illinois Tool Works (ITW) since January 2012. It is headquartered in Hatfield, Pennsylvania.
Seven Star LLC is an independent supplier listing Brooks Instrument thermal and Coriolis mass flow controllers and variable area flowmeters for buyers in Oman and the GCC. Instruments are matched from the model code and the gas, range and calibration data on the label.
Brooks Instrument at a glance
| Origin | Founded in 1946 by Stephen A. Brooks as the Brooks Rotameter Company, Lansdale, Pennsylvania |
|---|---|
| Headquarters | Hatfield, Pennsylvania, USA |
| Ownership | Emerson division until 31 December 2007, then American Industrial Partners; part of ITW since January 2012 |
| Product families | Thermal, pressure-based and Coriolis mass flow controllers and meters, metal tube and glass tube variable area flowmeters, pressure and vacuum products |
| Typical duty | Precise gas and liquid flow control in process, laboratory, analyser, fuel cell and semiconductor applications |
Brooks mass flow controllers and flowmeters
| Series | Type | Typical use |
|---|---|---|
| SLA5800, SLAMf | Thermal mass flow controllers and meters | Gas flow control in process and analytical systems; SLAMf with an IP66 enclosure for harsh or outdoor locations |
| 5800E | Analog thermal mass flow controller | Installed base in older systems; often replaced with the SLA5800 series |
| Quantim QMC | Coriolis mass flow controller | Low-flow liquid and gas control independent of fluid properties |
| GF40, GF80, GF100, GP200 | Metal-sealed thermal and pressure-based mass flow controllers | High-purity and semiconductor gas delivery; MultiFlo allows gas and range changes without recalibration |
| MT3750C, MT3809G | Metal tube variable area flowmeters | Purge, chemical injection and utility flows at higher pressure and temperature, with optional transmitter and alarms |
| GT1600, Sho-Rate 1250/1255 | Glass tube variable area flowmeters | Visual flow indication on purge, sample and laboratory lines |
Where Brooks instruments are used
Brooks mass flow controllers dose gases in analyser systems, catalyst and pilot plant testing, gas blending, burner and combustion control, fuel cell test stands and semiconductor tools. Variable area flowmeters are widely used on purge gas, seal flush, sample and chemical injection lines in oil and gas, refining and petrochemical plants, where a simple local indication without external power is preferred.
Ordering Brooks instruments: what we need
Send the full model code and serial number from the label. Mass flow controllers are calibrated for a specific gas and full-scale flow, so state the gas or gas mixture, flow range, inlet and outlet pressure, temperature, process connection, seal material, signal (analog, RS-485, DeviceNet, EtherNet/IP or other) and any hazardous-area requirement. For variable area meters add the fluid, density, viscosity, flow range, connection size, materials and whether alarms or a 4-20 mA output are needed.
Facts checked against Brooks Instrument company information and product data, October 2026.
Browse Brooks Instrument products by category: Flowmeters.
Related products
Frequently Asked Questions
Mass flow of liquids and gases directly, with simultaneous volume flow, density and temperature outputs.
From 0.001 kg/hr up to more than 27 kg/hr, depending on tube size and fluid.
Brooks states it is compatible in fit, form and function with second-generation QMB models.
IP40 and IP66, with optional UL Class 1 Division 2, ATEX Zone 2 and IECEx Zone 2 versions.
The free Brooks Expert Support Tool (BEST), connected through the 2.5 mm service jack.