Brand:

Leybold 10770400V01 VACUBE VQ 400 i Oil-Sealed Screw Vacuum Pump

Description

Variable-speed screw vacuum on demand: the VACUBE VQ 400 i

Leybold 10770400V01 is the VACUBE VQ 400 i in the front-panel version, the smallest size of the Leybold VACUBE VQ 400 to VQ 800 range. VACUBE is a family of intelligent single-stage oil-sealed screw vacuum pumps with variable speed drive (VSD) technology: the pump generates vacuum on demand, controlled and maintained by an internal controller, instead of running at full speed all the time. The maximum effective pumping speed of the VQ 400 is 420 m3/h (247 cfm).

The part number ends in V01, which marks the i model with a front panel. The same VQ 400 platform is also ordered as the iH version for high water vapour ingress (10770400V10) and with an HMI controller (V05 or V15), so the suffix decides what arrives on site.

Technical data for VQ 400 from the catalogue

Parameter Specification
Part number / type 10770400V01 / VACUBE VQ 400 i, model with front panel
Maximum effective pumping speed 420 m3/h (247 cfm)
Ultimate pressure 0.35 mbar (0.26 Torr), printed once for the whole VQ 400 to 800 table
Optimal pressure range 5 to 400 mbar (3.75 to 300 Torr)
Motor shaft power 5.5 kW (7.5 hp)
Controller VAControl
Noise level 51 to 65 dB(A), first value group in the shared VQ 400 to 800 row
Ambient temperature 0 to 46 degrees C (32 to 115 degrees F)
Weight 500 kg (1102 lbs), first value in the shared weight row
Protection class IP 54
Supply voltage 380 to 460 V, 3-phase, 50/60 Hz
Cooling Air cooled, vertical cooling air flow
Inlet flange DN 80 PN 10
Exhaust flange DN 65 (non-standard)

Model suffixes and what they mean

Version Meaning in the catalogue VQ 400 part number
i, front panel Intelligent VSD pump, ideal for low-vapour applications such as central vacuum holding, lifting and moving of parts 10770400V01
iH, front panel High water vapour tolerance for humid applications 10770400V10
i, HMI As i, with HMI controller 10770400V05
iH, HMI High water vapour tolerance with HMI 10770400V15

The catalogue also describes iC and iCH versions: iC is designed for short-cycling applications such as packaging or electronics assembly lines, and iCH combines high water vapour tolerance with short-cycling ability.

Controllers, connectivity and accessories

Every VACUBE comes with an on-board controller. The MK5 controller offers setpoint pressure control, temperature management, gas ballast management, alarms and warnings, timers with a work period calendar and maintenance interval follow-up, and can be connected to a PLC through a fieldbus or read out over a local Ethernet connection. The Leybold VAControl controller adds remote monitoring through local access, Wi-Fi, LAN or cloud communication, diagnostics and energy efficiency views. For several pumps, the Multi-VAControl central controller (part number 10430001V01) synchronises up to 20 pumps and can manage a spare pump for redundancy, and up to 3 sensors can be connected.

Accessory Part No.
Multi-VAControl central controller 10430001V01
Wi-Fi option for VACUBE or Multi-VAControl 3002615051
NPT 3 inch threaded inlet 177005A50
NPT 2-1/2 inch threaded outlet 177005A60
Manual inlet valve for VQ 400-800 177005A78
Power transformer 200-230 V, by model 177005A80 / 177005A82 / 177005A83
Power transformer 500-575 V, by model 177005A84 / 177005A86 / 177005A87

Installation notes

  • The catalogue gives installation requirements for the VQ 400 to VQ 800: keep the clearances shown for cooling air, which flows vertically through the pump.
  • Operating ambient is 0 to 46 degrees C, which is broader than most oil-sealed pumps, but a GCC plant room should still be ventilated to stay inside the limit.
  • At about 500 kg the pump needs lifting gear and a level floor; the footprint is described as pallet size for models up to 790 m3/h.
  • The 380-460 V, 50/60 Hz supply and IP 54 enclosure suit indoor factory installation. For 200-230 V or 500-575 V networks the catalogue lists transformers.

Industries and uses

Applications printed for VACUBE include packaging (modified atmosphere and skin packaging, canning), food processing, woodworking and wood lamination, plastics thermoforming, glass forming and handling, print and paper, lithium-ion cell manufacturing, coating, pipeline drying and vacuum cooling. A pump that tracks demand with its variable speed drive saves power in plants where the vacuum load changes through the day.

Tell us the suffix you need (V01, V05, V10 or V15), the supply voltage and whether a central controller is wanted. More equipment is in the pumps category.

Selection and installation notes

A vacuum pump is selected from the pumping speed, the ultimate pressure and the gases or vapours it will handle. Use the oil grade the maker names, check the oil level before starting, connect the exhaust to a safe place and fit an oil mist filter where needed, use a trap or filter ahead of the pump for dust and vapour and warm the pump before pumping condensable vapour. Service the oil and filters on the schedule in the manual.

Information needed for a quotation

Send the full model code, the quantity, the delivery location in Oman or the GCC, the intended use and any accessories needed, so that the complete package can be quoted together.

Documents and supply information

The manufacturer data sheet is attached to this page and should be read together with the project specification and the site risk assessment before a purchase is confirmed. Ratings, standards and dimensions are quoted as printed on that sheet. Lead time, stock position and certificates available with the shipment are confirmed in the quotation, and we supply to Oman and the wider GCC region for industrial, utility and building services projects.

Frequently asked questions

What is Leybold 10770400V01?

It is the VACUBE VQ 400 i oil-sealed screw vacuum pump with variable speed drive, front-panel model.

What pumping speed does the VQ 400 offer?

Up to 420 m3/h (247 cfm) maximum effective pumping speed, with an ultimate pressure of 0.35 mbar (0.26 Torr) as printed.

What supply is needed?

380 to 460 V, three-phase, 50/60 Hz; transformers for 200-230 V and 500-575 V are listed as accessories.

How do iH and V10 differ from this i model?

iH is the variant with high water vapour tolerance, ordered as 10770400V10 for the VQ 400.

Is Seven Star LLC the VACUBE manufacturer?

No. Seven Star LLC is an independent supplier in Muscat that checks suffix and voltage with you before an order.

Datasheets & Documents
  • PDF Datasheet Leybold Full Line Catalog 2022, oil sealed vacuum pumps: VACUBE VQ 400 i to VQ 800 i extract (catalogue pages 174-179) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Leybold is a German manufacturer of vacuum pumps and vacuum technology, headquartered in Cologne, with a history that goes back to 1850. Ernst Leybold's firm became known for vacuum research, including Wolfgang Gaede's work on the turbomolecular principle in 1911 and the diffusion pump in 1913. Leybold was part of Oerlikon until September 2016, when Atlas Copco completed its acquisition.

Seven Star LLC is an independent supplier in Muscat. We list selected Leybold pumps with the official catalogue pages for industrial and laboratory users in Oman and the GCC.

Leybold company profile

Origins 1850, Cologne, Germany
Headquarters Cologne, Germany
Ownership Atlas Copco, since September 2016
Previous owner Oerlikon
Product families SOGEVAC single-stage and TRIVAC two-stage rotary vane pumps (including ATEX versions), NEO D rotary vane pumps, VACUBE screw pumps, dry screw and Roots pumps, turbomolecular pumps, vacuum gauges

Milestones

  • 1850: The business is founded in Cologne.
  • 1911: The turbomolecular pump principle is developed with Wolfgang Gaede.
  • 2016: Atlas Copco acquires Leybold.
  • 2025: Leybold marks 175 years.

Leybold product series

SOGEVAC single-stage oil-sealed rotary vane pumps on this site include the SV 16 D, SV 25 B, SV 100 B and SV 220 B, and the SV 40 ATEX Category 2 pump for gas group IIB+H2. Two-stage rotary vane pumps include the NEO D 25 and the TRIVAC D 40 B, and the TRIVAC D 16 B-Ex is an explosion-protected version.

The VACUBE VQ 400 i and VQ 700 i are oil-sealed screw vacuum pumps with variable speed drive for larger volume flows. The catalogue numbers (for example 960 250) identify the exact pump variant and motor.

Where Leybold pumps are used

Vacuum packaging and food processing, drying and degassing, coating, metallurgy and heat treatment, transformer and power engineering work, chemical processes, laboratories and analytical instruments. ATEX versions serve areas where explosive gases may be pumped.

Leybold products we list

Family Examples
Pumps 10770400V01 VACUBE VQ 400 i Oil-Sealed S…, 112 86 TRIVAC D 40 B Two-Stage Rotary Va…, 140 091 TRIVAC D 16 B-Ex Explosion Prote…, 960 250 SOGEVAC SV 25 B Rotary Vane Vacu…, 960 345 SOGEVAC SV 40 ATEX Cat 2 Vacuum…, 970202V NEO D 25 Two-Stage Rotary Vane V…

Ordering Leybold pumps: what we need

Send the Leybold catalogue number from the nameplate, or the pumping speed, ultimate pressure, gas or vapour being pumped, motor voltage and frequency, and any ATEX requirement. For service, state the pump model and serial number so the right oil, filters and kits can be quoted.

Facts checked against Leybold's own 175-year release and Atlas Copco announcements, October 2026.

Frequently Asked Questions

What is Leybold 10770400V01?
It is the VACUBE VQ 400 i oil-sealed screw vacuum pump with variable speed drive, front-panel model.
What pumping speed does the VQ 400 offer?
Up to 420 m3/h (247 cfm) maximum effective pumping speed, with an ultimate pressure of 0.35 mbar (0.26 Torr) as printed.
What supply is needed?
380 to 460 V, three-phase, 50/60 Hz; transformers for 200-230 V and 500-575 V are listed as accessories.
How do iH and V10 differ from this i model?
iH is the variant with high water vapour tolerance, ordered as 10770400V10 for the VQ 400.
Is Seven Star LLC the VACUBE manufacturer?
No. Seven Star LLC is an independent supplier in Muscat that checks suffix and voltage with you before an order.