Brand:

Viking Pump HL897 Stainless Steel Mag Drive Gear Pump

Description

Overview

Viking Pump HL897 is the 30 GPM member of the stainless steel 897 mag drive family. It has 1 1/2 inch ports, a nominal capacity of 30 GPM (6.8 m3/h) at 1800 rpm or 20 GPM (4.5 m3/h) at 1200 rpm and a pump weight of about 30 lb (14 kg). Like all 897 pumps it uses a Viking Mag Drive coupling in place of a shaft seal, so hazardous liquids stay inside the pump. Seven Star LLC is an independent supplier serving Oman and the GCC.

A larger displacement in the same envelope

The HJ and HL pumps share a casing envelope and port size, which means the piping and base are the same. What distinguishes the HL is the longer gear set, which sweeps more liquid per turn. That extra displacement also asks for more torque from the coupling, so the HL is typically paired with the MD-A at 1800 rpm for thin liquids and the MD-B at 1200 rpm, rated at a maximum of 40 foot-pounds (54 Nm), where the liquid is thicker. Because the pump is dimensionally interchangeable with the HJ, an installation can be upgraded from 20 to 30 GPM without rebuilding the pipework.

Viking Pump HL897 technical data

Parameter Value
Model Viking Pump HL897, series 897, stainless steel mag drive, catalog section 1743
Port size 1 1/2 inch (40 mm)
Nominal rating (100 SSU and below) 30 GPM (6.8 m3/h) at 1800 rpm; 20 GPM (4.5 m3/h) at 1200 rpm
Magnetic coupling MD-A at 1800 rpm; MD-B (40 ft-lb, 54 Nm) at 1200 rpm
Casing Stainless steel, ASTM A743 Grade CF8M
Head and rotor Stainless steel, ASTM A743 Grade CF8M, case hardened
Idler PPS composite standard; non-galling stainless optional
Rotor shaft and idler pin Hard coated stainless steel, ASTM A276 Type 316
Bushings Carbon graphite standard; silicon carbide optional
Canister 316L stainless steel (316 on MD-A couplings)
Magnets Neodymium iron boron standard; samarium cobalt optional
O-rings PTFE derivative encapsulated; FKM or FFKM optional
Maximum hydrostatic pressure 400 PSIG (28 bar)
Series operating pressure 125 PSI (8.5 bar)
Standard maximum temperature 225 F (105 C); higher with samarium cobalt magnets
Series viscosity range 28 to 25,000 SSU (1 to 5,500 cSt)
Approximate pump weight, less power about 30 lb (14 kg)

Choosing between Viking Pump HL897 and the AS897

The next frame, the AS897, has 3 inch ports and delivers 35 GPM at 1200 rpm, with a pump weight of about 78 lb (35 kg) and a choice of MD-B or MD-C couplings. If you need 30 GPM, the HL at 1800 rpm is the smaller, lighter option, but it runs at a higher speed and therefore suits thin liquids best. If the liquid is viscous, a slower AS with a larger port may deliver more reliably. So think about viscosity first and port size second.

Applications

  • Loading of hazardous liquids to tankers or isotanks.
  • Circulation of reactive chemicals through coolers.
  • Transfer of refined fuels and lube oils in sealless service.
  • Handling of liquids that are hard to seal because of low viscosity or crystallisation.

Materials

Casing is cast stainless steel CF8M and the head and rotor are case hardened CF8M. The idler is PPS composite by default with a non-galling stainless option. Shafts and pins are hard coated 316 stainless. Standard bushings are carbon graphite, with silicon carbide for abrasive services. The canister is 316L stainless steel, the magnets are neodymium iron boron and the standard O-rings are PTFE derivative encapsulated, with FKM and FFKM as options.

Limits of use

Standard temperature limit is 225 F (105 C), with samarium cobalt magnets used for higher temperatures. The series operating pressure is 125 PSI (8.5 bar) with a hydrostatic limit of 400 PSIG (28 bar), and viscosity can range from 28 to 25,000 SSU. A metal idler is advised above 10,000 SSU. Always check that the liquid is free of magnetic particles.

Installation sequence

Mount the pump on a solid base, fit the bearing carrier and driver, and check alignment with the piping connected. Install a strainer and a pressure gauge. Fill the casing and bleed air before starting. Run the pump for a short time and watch for noise or temperature rise. The optional temperature probe port allows continuous monitoring of the canister region.

Service

Plan inspection of bushings and thrust washers at regular intervals, since these are the wear parts. Keep spare O-rings and a bushing set. Do not run dry for long periods and do not start against a closed discharge.

Suction side and NPSH

A gear pump delivering 30 GPM at 1800 rpm needs adequate suction head, especially on viscous liquids. The catalog includes NPSH required curves for each size, and the available head at your tank should exceed the required value by a safe margin. Keep the suction pipe short and no smaller than the port, avoid sharp elbows near the inlet, and fit a strainer with ample area. If the margin is small, reduce the speed with a gear reducer, since the magnetic coupling can transmit the torque of a slow-speed drive.

Handling hazardous liquids safely

A sealless pump contains the liquid, but a safe installation still needs care. Provide drip protection under the pump, a drain valve on the casing line and a vent for gas freeing. Make provision for flushing before maintenance, and wear the right protection when the pump is opened. If the liquid is flammable, the drive motor, coupling guard and any temperature probe must meet the hazardous area classification of the site. When the liquid is toxic, route the relief valve return to the suction line or to the supply tank in accordance with the plant safety procedure.

Magnetic particles and cleanliness

Neodymium magnets attract iron and steel particles. Rust flakes or weld debris in a new pipeline may therefore collect on the inner magnet and cause rubbing against the canister. Flush new piping before connecting the pump, fit a strainer, and consider a magnetic trap in the suction line if the system has carbon steel pipework.

Related items you may also need: KRACHT Pump Technology Series | Verder VA25 Air-Operated Double Diaphragm Pump | Allweiler ALLFUEL AFI Horizontal Screw Pump for Fuels and Oils | All Viking Pump products.

Checklist before ordering the Viking Pump HL897

  • Before ordering the Viking Pump HL897, compare the nameplate of the unit being replaced with the code shown on this page, character by character.
  • Our team confirms the Viking Pump HL897 code and lead time in writing before any order is placed.
  • The datasheet attached to this page is the reference for the Viking Pump HL897 dimensions, ratings and connections.
  • The Viking Pump HL897 is listed in our positive displacement pumps range and ships to sites across Oman and the GCC.
  • Spare quantities of the Viking Pump HL897 are worth planning for critical duty so that a failure does not stop production.

Documents and quotation

The Viking catalog section for the 897 series is attached. For a quotation on Viking Pump HL897, please send quantity, liquid, temperature, pressure, drive arrangement and delivery location in Oman or the GCC.

Other Models in the Viking 897 Range

Seven Star LLC supplies models from the Viking 897 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Viking Pump GG897 Stainless Steel Mag Drive Gear PumpPositive Displacement PumpsView details
Viking Pump HJ897 Stainless Steel Mag Drive Gear PumpPositive Displacement PumpsView details
Viking Pump HL897 Stainless Steel Mag Drive Gear PumpPositive Displacement PumpsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Viking Pump HL897 Stainless Steel Mag Drive Gear Pump Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Viking Pump is the American maker of positive displacement pumps best known for the internal gear pump, often described as the "gear-within-a-gear" design. The principle goes back to Jens Nielsen, a Danish-born quarry owner in Cedar Falls, Iowa, who needed a better way to drain water from his quarry and patented his internal gear pump in 1904. In 1911 Nielsen and three local partners formed the Viking Pump Company in Cedar Falls, which is still the company's home. Viking has been part of IDEX Corporation since 1989.

Viking Pump company profile

Founded 1911, Cedar Falls, Iowa, USA, by Jens Nielsen with P.C. Petersen, W.L. Hearst and George Wyth
Headquarters Cedar Falls, Iowa, USA
Ownership A unit of IDEX Corporation since 1989
Core technology Internal gear pumps (rotor, idler gear and crescent), plus external gear, vane, lobe and circumferential piston pumps
Typical liquids Viscous and difficult liquids: fuel and lube oils, asphalt and bitumen, resins, polymers, chemicals, ammonia, molasses, inks and adhesives
Standards API 676 versions for refinery and petrochemical service; jacketed and heated versions for liquids that must be kept hot

Milestones

  • 1904: Jens Nielsen patents his internal gear pump design.
  • 1911: Viking Pump Company is founded in Cedar Falls, Iowa.
  • 1989: Viking becomes part of IDEX Corporation.
  • 2011: Viking marks 100 years in Cedar Falls.
  • Today: Internal and external gear pumps, mag drive pumps and API 676 pumps sold through distributors worldwide.

How a Viking internal gear pump works

An internal gear pump has two moving parts: an outer rotor gear and a smaller idler gear that turns inside it, offset on a pin. A crescent-shaped partition on the head fills the space between them. As the gears come out of mesh on the suction side, liquid fills the opening tooth spaces, is carried around both sides of the crescent and is pushed out as the teeth mesh again on the discharge side. Flow is smooth and almost proportional to speed, so the same pump can handle thin solvents or very thick liquids. The pump is reversible, and an internal relief valve is often fitted to protect it if the discharge is blocked. For thick liquids, choose a larger pump at a lower speed; for hot products such as asphalt, choose a jacketed or heated version.

Where Viking pumps are used in Oman and the GCC

In the region, Viking pumps move fuel oil, lube oil and base oils in refineries and terminals, bitumen and asphalt in road-building and storage plants, resins and chemicals in petrochemical plants, and ammonia in refrigeration systems. External gear pumps such as the GB series are used for chemical injection into pipelines, and mag drive pumps are chosen where a seal leak is not acceptable.

Viking Pump models we list

Family Examples
General-purpose internal gear pumps KK124C, H1124C O-Pro, QS124C, M124A, N324A, RS4324A
Jacketed and heated pumps KK224C, Q224C, M224A, KK124E asphalt
Steel and stainless steel pumps L123C, QS4123C, RS4323A, KK127C, Q4127C
API 676 pumps LS4223AX, Q4223AX, N4323AX, R4323AX, KK4223AA
Motor speed, external gear and mag drive pumps HL495, AK4195, GB-41013, GB-41430, SG-0741, AK893 mag drive
Special-duty pumps KK4924A ammonia, KK4624C abrasive, LVP41027 vane

Ordering Viking pumps: what we need

Send the full model number and serial number from the nameplate. The letters at the start of the model (for example G, H, KK, LS, Q or RS) give the pump size, and the digits give the construction, seal and material. For a new pump, tell us the liquid, its viscosity and temperature, the flow rate, the discharge pressure, the port size and whether you need a jacket, a relief valve, a motor and baseplate, or API 676 construction. For spares, send the model and serial number and say whether you need the rotor, idler, idler pin, bushing or seal kit.

Facts checked against Viking Pump and IDEX company history and published Viking product catalogues, November 2026.

FAQ

Questions about the Viking Pump HL897 Stainless Steel Mag Drive Gear

Answers from our engineering team on installation, compatibility and integration.

01What flow does the Viking Pump HL897 deliver?
The catalog rating is 30 GPM (6.8 m3/h) at 1800 rpm and 20 GPM (4.5 m3/h) at 1200 rpm on liquids of 100 SSU and below.
02How does the HL897 differ from the HJ897?
They share 1 1/2 inch ports and a 30 lb pump weight, but the HL delivers 30 GPM where the HJ delivers 20 GPM at 1800 rpm.
03What materials does the HL897 use?
Cast stainless steel CF8M for casing, head and rotor, a PPS composite idler, a 316L canister and carbon graphite bushings.
04What pressure applies to the HL897?
The series operating pressure is 125 PSI (8.5 bar), with a hydrostatic limit of 400 PSIG (28 bar).
05Which coupling does the HL897 use?
MD-A at 1800 rpm and MD-B at 1200 rpm according to the catalog, with MD-B rated at 40 ft-lb (54 Nm).