Brand: SERVOMEX
SERVOMEX FluegasExact 2700 Oxygen and Combustibles Analyzer
Description
Overview
Fired heaters and boilers waste fuel and make pollutants when the air-to-fuel ratio drifts, so operators watch oxygen and combustibles in the flue. The SERVOMEX FluegasExact 2700 is a SERVOTOUGH combustion gas analyzer that measures both. It pairs a zirconium oxide cell for oxygen with a thick film catalytic sensor for carbon monoxide and combustibles (COe) in a heated, low-flow extractive sensor head, for processes with gas temperatures up to 1750 degrees Celsius. Seven Star LLC is an independent supplier serving Oman and the GCC.
Design of the SERVOMEX FluegasExact 2700
The sensor head attaches directly to the flue or can be remote mounted, and it is a fully heated stainless steel design certified for Zone 2 and Division 2 monitoring. High temperature and flow sensor options extend its performance. A separate control unit carries the display, relays and analog outputs. The manufacturer states that combining oxygen and combustibles measurement improves process control, helps optimize excess oxygen, reduces SOx, SO3 and CO emissions, and has been proven to save up to four percent of fuel costs per year.
SERVOMEX FluegasExact 2700 installation and environment data
| Measured gases | Oxygen (zirconium oxide cell) and carbon monoxide / combustibles COe (thick film catalytic sensor) |
|---|---|
| Process temperature | Up to 1750 C (3182 F) |
| Sensor head mounting | 4 inch flange, 8 holes of 19 mm at 45 degree intervals on 190.5 mm pitch circle, at least four M16 or 5/8 inch bolts |
| Weld-on flange | Part 02750409, square 250 x 250 mm, 8 threaded M16 holes; cut a 102 to 127 mm hole in the duct wall |
| Adaptor flange kits | Include 3 inch ANSI 150 and DIN 65 PN16 patterns, and Model 700B pattern |
| Sensor head ambient | -20 to +70 C operating; -30 to +80 C storage |
| Sensor head ingress | IP66 and NEMA 4X |
| Control unit ambient | -10 to +55 C operating; -20 to +55 C storage |
| Control unit ingress | IP66 and NEMA 4X |
| AC supply | Factory set 100-120 V or 220-240 V, 50/60 Hz (minus 15 percent, plus 10 percent) |
| Altitude / humidity | Up to 2000 m; 0 to 80 percent RH |
| Installation category | Category II, pollution degree 2 for the electronics |
| Anti-seize compound | Part number 1761-3211, supplied in the installation kit |
Typical applications in Oman and the GCC
The manufacturer names process heaters, utility boilers, thermal crackers, incinerators and furnaces in hydrocarbon processing and power generation. In Oman and the GCC these correspond to refinery and petrochemical fired heaters, steam boilers at power and desalination plants, waste incineration units and reformer furnaces, where tight excess oxygen control cuts fuel bills and reduces emissions.
How FluegasExact 2700 differs from other Servomex combustion analyzers
- SERVOMEX FluegasExact 2700 measures both oxygen and combustibles and is rated to 1750 C process temperature; the Oxy 1900 and 1810 family measure oxygen only.
- It uses a heated extractive head on a 4 inch flange, unlike in-situ zirconia probes without a sample system.
- Compared with Laser 3 Plus combustion analyzers, which use tunable diode laser technology, the 2700 uses zirconia and catalytic sensors.
Why measure combustibles as well as oxygen with the SERVOMEX FluegasExact 2700
Oxygen alone shows how much excess air is present, but it cannot show whether combustion is complete at that level. A burner with poor mixing can show healthy oxygen while still producing carbon monoxide, which is wasted fuel and a safety concern. The catalytic sensor in this analyzer reports CO and combustibles (COe), so the operator can trim air down until combustibles just begin to rise, then hold a margin. Operating close to that point is where the quoted fuel savings come from, and it also lowers SOx and SO3 formation, which reduces fouling and acid corrosion in cold-end equipment.
The analyzer is also useful as a safety watch on furnaces, because a sudden rise in combustibles flags flame instability before a trip. Process engineers can wire the relays into burner management systems as an alarm, not as a safety-rated trip, and use the analog outputs for the combustion trim controller.
Reading the specification tables
The manufacturer publishes environmental data separately for the two enclosures. The sensor head tolerates -20 to +70 C ambient and has a pollution degree 4 probe tip protruding into the flue, while the control unit is limited to -10 to +55 C and should be installed in a shaded place away from the flue if the site is hot. Both are IP66 and NEMA 4X, so hose-down and rain are acceptable provided the covers remain fitted.
Installation steps
Choose the flange method first: a 4 inch ANSI 150 flange can take the head directly, a weld-on flange can be fitted if there is none, and adaptor kits cover other patterns. Use the anti-seize compound on mounting bolts and studs; the installation manual warns that other release compounds may permanently damage the combustibles sensor. Do not lift the sensor head by the compressed air pipe that runs from the solenoid valve. Mount the control unit within the environmental limits and wire power, analog outputs and relays following the installation manual tables for oxygen only, combustibles only or dual sensor wiring.
Maintenance
Service work follows the dedicated service manual (part 02700002C), and the QuickStart manual (02700003C) covers day-to-day operation. The head has a low-flow extractive design intended for minimal maintenance. Spare parts such as the control unit PCBs, display and fuse kits are available as separate items.
Related products and ordering notes
For a quotation on SERVOMEX FluegasExact 2700, state whether oxygen only, combustibles only or both sensors are needed, the flange pattern, the supply voltage and the probe length.
Related items you may also need: Servomex S2710913A Control Unit PCB COe Only for FluegasExact 2700 | Servomex S1804989B High-Flow O2 Transducer for Oxy 1800 | Servomex S4000988 Internal Filter Elements 6M Pack, SERVOPRO 4000 | All SERVOMEX products.
Before you order the SERVOMEX FluegasExact 2700
- To avoid a wrong delivery, compare the code on the nameplate of the installed unit with the SERVOMEX FluegasExact 2700 code on this page.
- The quotation for the SERVOMEX FluegasExact 2700 states the confirmed code and the lead time to site.
Configuring the SERVOMEX FluegasExact 2700 for your process
The SERVOMEX FluegasExact 2700 is a model family that Servomex builds to a configuration, so the orderable unit is fixed by the options below and not by the model name alone.
- Measuring range and the gas or sample the SERVOMEX FluegasExact 2700 will analyse.
- Output signals and communication needed by your control system, for example 4-20 mA, relays or a digital protocol.
- Supply voltage and the mounting style required on site.
- Hazardous area classification of the installation location, if any.
- Sample handling and process connection details, including pressure, temperature and any sampling system or accessories.
Send these details, or the full code from the nameplate of an existing unit, and the quotation will confirm the exact configuration before order.
Documents and quotation
The installation manual for the SERVOMEX FluegasExact 2700 (part 02700005C) is attached on this page and covers environment, mounting, wiring and gas requirements. To check availability, send an RFQ to Seven Star LLC with the model SERVOMEX FluegasExact 2700, the quantity and your destination in Oman or the GCC.
Datasheets & Documents
- Datasheet SERVOMEX FluegasExact 2700 Oxygen and Combustibles Analyzer Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Servomex is a British specialist in gas analysis, founded in 1952 by Richard Steel, John Crockett and Ronald Mudie; the name comes from servomechanism. It first made electronic products, then built its first paramagnetic oxygen analyser in 1961 after work with Charles Munday on a paramagnetic sensor. Servomex is based in Crowborough, East Sussex, and is part of Spectris.
Seven Star LLC lists Servomex process, combustion, emissions and portable gas analyzers, plus accessories, and sources them for refineries, petrochemical plants and industrial gas producers in Oman.
SERVOMEX company profile
| Founded | 1952, United Kingdom |
|---|---|
| Founders | Richard Steel, John Crockett and Ronald Mudie |
| Headquarters | Jarvis Brook, Crowborough, East Sussex |
| Ownership | Spectris plc, since 1999 |
| Key technologies | Paramagnetic oxygen sensing (1961), infrared analysis (1969), zirconia oxygen sensors (1981) |
| Product families | MultiExact and SERVOPRO MultiExact analysers, SERVOTOUGH OxyExact and Oxy 1800 oxygen analysers, SERVOTOUGH Laser 3 Plus TDL analysers, SERVOFLEX portable analysers, zirconia combustion analysers |
Milestones
- 1952: Servomex is founded.
- 1961: The first Servomex paramagnetic oxygen analyser is introduced.
- 1981: Servomex introduces zirconia oxygen sensors.
- 1999: Spectris acquires Servomex.
Servomex analyzer families listed
Servomex groups its analyzers under family names that indicate where they can be used. SERVOTOUGH covers analyzers built for hazardous areas and field mounting, SERVOPRO covers units for general purpose areas and analyzer houses, and SERVOFLEX is the portable line. On this page:
- SERVOTOUGH OxyExact 2200: paramagnetic oxygen analyzer for process control and safety
- SERVOTOUGH SpectraExact 2500: photometric analyzer for process gas components
- SERVOTOUGH Laser 3 Plus: compact tunable diode laser analyzer for combustion
- SERVOPRO 4900 Multigas: multi-component analyzer for emissions monitoring
- SERVOPRO NanoTrace DF-550E: ultra-trace oxygen analyzer for high purity gases
- SERVOFLEX Micro i.s. 5100: intrinsically safe portable oxygen analyzer
A flow alarm relay box for the 2700 flue gas analyzer is also listed.
Where Servomex gas analyzers are used
Typical duties are oxygen measurement for inerting and blanketing, vapor recovery and flare header safety, combustion control on fired heaters and reformers, purity control in air separation and electronic gases, and continuous emissions monitoring. In the GCC the main users are refining, petrochemicals, fertilizer, LNG and industrial gas plants.
SERVOMEX products we list
Ordering Servomex analyzers and spares: what we need
A Servomex gas analyzer is built to an order code that fixes the measured gas, range, sample wetted materials, outputs and hazardous area approval. For replacements and spare parts, send the model, the serial number and the order code from the data plate. For a new Servomex oxygen analyzer or multigas unit, send the full stream composition, the component and range to be measured, sample pressure and temperature, the area classification, power supply and communication needs. We check the configuration against Servomex documentation before quoting.
Facts checked against Servomex's own 70-year history and company profiles, October 2026.
Browse SERVOMEX products by category: Gas Analyzer Systems, Gas Analyzer Accessories, Portable Test & Measurement.
FAQ
Questions about the SERVOMEX FluegasExact 2700 Oxygen and Combustibles
Answers from our engineering team on installation, compatibility and integration.
01What does the FluegasExact 2700 measure?
It measures oxygen with a zirconium oxide cell and carbon monoxide and combustibles (COe) with a thick film catalytic sensor in a heated extractive sensor head.
02What process temperature can the FluegasExact 2700 handle?
It is designed for high temperature processes up to 1750 C (3182 F), with high temperature and flow sensor options for extreme environments.
03How is the FluegasExact 2700 mounted?
The sensor head has a 4 inch flange with 8 holes of 19 mm on a 190.5 mm pitch circle, fitting 4 inch ANSI 150 flanges or a weld-on or adaptor flange.
04What ingress protection does the FluegasExact 2700 have?
Both the sensor head and the control unit are rated IP66 and NEMA 4X, with the head operating from -20 to +70 C.
05What fuel saving is claimed for the FluegasExact 2700?
Servomex states that combined oxygen and combustibles control has been proven to save up to four percent of fuel costs per year.