Brand: SERVOMEX
Servomex S2501911A Power Control PCB for SpectraExact 2500
Description
Servomex S2501911A: the power control board of the 2500
Servomex S2501911A is the Power Control PCB listed in the General Spares table of the SpectraExact 2500 series manual. It is the board that handles the high-current duties: the infrared source supply, the cell heater control and the relays that switch auto calibration valves. The manual identifies it by name and number in the wiring section, calling it the 2500 Power Control PCB 02501911A, and the spares table gives the orderable number with the S prefix, S2501911A. Operators meet the board through fault messages: several of the general faults are annotated with the words possible Power Control PCB fault.
We describe the part so that buyers can see what it covers. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
What the board connects to
- Sample flow failure input, terminals TB36-1 and TB36-2, by contact closure; the alarm only clears when the contacts open again.
- Auto calibration solenoid valve relays, rated 240 VAC at 1.0 A or 30 VDC at 1.0 A, with an R-C snubber of 100 R and 47 nF.
- Internal 24 VDC at 12 VA solenoid supply, which must not be overloaded.
- Source supply and cell heater control, as implied by the source and cell temperature fault entries.
| Parameter | Value |
|---|---|
| Part number | S2501911A |
| Description | Power Control PCB, General Spares list |
| Flow fail input | TB36-1 to TB36-2 |
| Relay rating | 240 VAC / 1.0 A, 30 VDC / 1.0 A |
| Snubber | 100 R plus 47 nF |
| Internal valve supply | 24 VDC, 12 VA |
| Heated cell supply | 300 VA with heated cell; 120 VA without |
| Supply voltage | 115/230 V or 100/200 V AC plus or minus 15 percent |
| Ambient range | 0 to 55 C |
| Certified versions | Only boards listed in the spares table may be used |
Fault messages that point to S2501911A
SOURCE VOLTAGE HIGH and SOURCE VOLTAGE LOW, logged as SOURCE HIGH and SOURCE LOW, and CELL TEMP HIGH and CELL TEMP LOW, logged as CELL T HIGH and CELL T LOW, are all annotated possible Power Control PCB fault in the manual. Contrast these with CELL TEMP SENSOR FAILURE, which points to the sensor or its wiring, and BAD REFERENCE VOLTAGE, which points to the Transmitter PCB S2500904A. Use this list before ordering.
How S2501911A differs from other boards
- S2500904A transmitter PCB: measurement electronics, not high-current switching.
- 02000934 sensor interface PCB: sensor signals.
- S2500906 motor connection PCB: chopper motor wiring.
- S2501911A: source, heater and valve power switching.
Solenoid valve considerations
Valves may use an external power source or the internal 24 VDC supply. Choose DC valves with built-in suppression diodes across the coil, and avoid very low power AC valves. In a hazardous area use certified valves. These notes guide whether a faulty valve, not the board, caused a calibration fault.
Replacement notes
Isolate the mains. The Power Control PCB sits within the analyser electronics; the Ethernet option PCB 02500913 is fitted vertically above it, so disconnect and set aside option boards in order. Fit the new board, restore cable screens and glands to the nearest earth stud, and test with the diagnostics.
Spares planning
The recommended spares table advises one sensor interface PCB and one power supply per four to nine analysers; add S2501911A where heated cells and automatic calibration make the analyser critical.
Typical analysers
The board is part of the SpectraExact 2500 range used in oil and gas, petrochemical and power plants in the GCC.
Remember the structure of the 2500: two cast end assemblies, with hinged or removable covers, joined by a rigid mounting beam. The detector end on the left holds the main circuit boards and the display panel in the hinged lid, while the source end on the right holds the source and chopper box. Boards listed in Table 6.1 include the transmitter PCB S2500904A, the sensor interface PCB 02000934, the option PCB 02000916, the motor connection PCB S2500906 and the power control PCB S2501911A, so use the part number exactly to avoid confusion.
The recommended spares list does not require a power control board for every site; however, plants with heated cells and automatic calibration valves should keep one because a failed board stops both the source supply and the heater control, leading to shutdown on a serious fault.
Before fitting, photograph the connector positions on the old board and check the cable screens, because the manual stresses screened cables with the screens attached to the nearest earth stud at minimum length. If the analyser is certified for a hazardous area, record the replacement in the certification file, since the manual restricts certified versions to the listed spare boards only.
For purchasing, quote S2501911A exactly, give the analyser serial number and note whether the version is certified. Keep the removed S2501911A until the new one has been proven in service, and log the source voltage and cell temperature readings afterwards. Because S2501911A switches heater and valve loads, check external wiring for shorts before power-up to avoid damaging the replacement.
Documents and quotation
The Servomex SpectraExact 2500 series manual, part number 02500005D, is the document we attach for Servomex S2501911A; its section 6 spares tables are the source of the part number and description. Please note whether the analyser is a certified version (EU1, EU2, DU1, EX1, EX2, DX1, FM2, DM2) when you request a quote. To request a quotation, send S2501911A, the quantity, the analyser serial number and the Final Specification Sheet reference if you have it, and your delivery location in Oman or the GCC. Each RFQ is answered with availability and lead time.
Other Models in the Servomex 2500 Range
Seven Star LLC supplies models from the Servomex 2500 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Servomex S2500931A Long Wave ZnSe Source Unit for SpectraExact 2500 | Gas Analyzer Systems | View details |
| Servomex S2501905C CVDFET Detector Unit for SpectraExact 2500 | Gas Analyzer Systems | View details |
| Servomex S2500980B BaF2 Window for SpectraExact 2500 | Gas Analyzer Systems | View details |
| Servomex S1200922 CW Boss Scrubber H2O/CO2 for SpectraExact 2500 | Gas Analyzer Systems | View details |
| Servomex S2501911A Power Control PCB for SpectraExact 2500 | Gas Analyzer Systems | You are viewing this model |
Datasheets & Documents
- Datasheet Servomex S2501911A Power Control PCB for SpectraExact 2500 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Servomex is a British specialist in gas analysis, founded in 1952 by Richard Steel, John Crockett and Ronald Mudie; the name comes from servomechanism. It first made electronic products, then built its first paramagnetic oxygen analyser in 1961 after work with Charles Munday on a paramagnetic sensor. Servomex is based in Crowborough, East Sussex, and is part of Spectris.
Seven Star LLC lists Servomex process, combustion, emissions and portable gas analyzers, plus accessories, and sources them for refineries, petrochemical plants and industrial gas producers in Oman.
SERVOMEX company profile
| Founded | 1952, United Kingdom |
|---|---|
| Founders | Richard Steel, John Crockett and Ronald Mudie |
| Headquarters | Jarvis Brook, Crowborough, East Sussex |
| Ownership | Spectris plc, since 1999 |
| Key technologies | Paramagnetic oxygen sensing (1961), infrared analysis (1969), zirconia oxygen sensors (1981) |
| Product families | MultiExact and SERVOPRO MultiExact analysers, SERVOTOUGH OxyExact and Oxy 1800 oxygen analysers, SERVOTOUGH Laser 3 Plus TDL analysers, SERVOFLEX portable analysers, zirconia combustion analysers |
Milestones
- 1952: Servomex is founded.
- 1961: The first Servomex paramagnetic oxygen analyser is introduced.
- 1981: Servomex introduces zirconia oxygen sensors.
- 1999: Spectris acquires Servomex.
Servomex analyzer families listed
Servomex groups its analyzers under family names that indicate where they can be used. SERVOTOUGH covers analyzers built for hazardous areas and field mounting, SERVOPRO covers units for general purpose areas and analyzer houses, and SERVOFLEX is the portable line. On this page:
- SERVOTOUGH OxyExact 2200: paramagnetic oxygen analyzer for process control and safety
- SERVOTOUGH SpectraExact 2500: photometric analyzer for process gas components
- SERVOTOUGH Laser 3 Plus: compact tunable diode laser analyzer for combustion
- SERVOPRO 4900 Multigas: multi-component analyzer for emissions monitoring
- SERVOPRO NanoTrace DF-550E: ultra-trace oxygen analyzer for high purity gases
- SERVOFLEX Micro i.s. 5100: intrinsically safe portable oxygen analyzer
A flow alarm relay box for the 2700 flue gas analyzer is also listed.
Where Servomex gas analyzers are used
Typical duties are oxygen measurement for inerting and blanketing, vapor recovery and flare header safety, combustion control on fired heaters and reformers, purity control in air separation and electronic gases, and continuous emissions monitoring. In the GCC the main users are refining, petrochemicals, fertilizer, LNG and industrial gas plants.
SERVOMEX products we list
Ordering Servomex analyzers and spares: what we need
A Servomex gas analyzer is built to an order code that fixes the measured gas, range, sample wetted materials, outputs and hazardous area approval. For replacements and spare parts, send the model, the serial number and the order code from the data plate. For a new Servomex oxygen analyzer or multigas unit, send the full stream composition, the component and range to be measured, sample pressure and temperature, the area classification, power supply and communication needs. We check the configuration against Servomex documentation before quoting.
Facts checked against Servomex's own 70-year history and company profiles, October 2026.
Browse SERVOMEX products by category: Gas Analyzer Systems, Gas Analyzer Accessories, Portable Test & Measurement.
FAQ
Questions about the Servomex S2501911A Power Control PCB for
Answers from our engineering team on installation, compatibility and integration.
01What does Servomex S2501911A do?
It is the Power Control PCB of the SpectraExact 2500; the manual ties source voltage and cell temperature faults to it and uses its relays to switch the auto calibration solenoid valves.
02Which terminals carry the loss of flow input?
The loss of flow diagnostic is triggered by contact closure between TB36-1 and TB36-2 on the 2500 Power Control PCB.
03What are the auto calibration relay ratings?
240 VAC at 1.0 A or 30 VDC at 1.0 A, with an R-C snubber of 100 R plus 47 nF.
04Can low power solenoid valves be used?
220/240 Vac valves below about 6 VA are not recommended because snubber leakage may keep them from de-energising.
05Can I use any board in a certified version?
No, the manual states that for certified versions only the listed boards may be used as spares.