Servomex S2500931A Long Wave ZnSe Source Unit for SpectraExact 2500

Description

Servomex S2500931A and the 2500 source end

Servomex S2500931A is the long wave source unit with a zinc selenide window, listed in Table 6.3 of the SpectraExact 2500 series manual. In the 2500 construction the source end, the right-hand side, holds the soft ultraviolet or infrared source and generates a broad beam across the needed spectrum. The source is mounted on the chopper box assembly, which carries the interference filters on a rotating wheel; the filters pick out one measurement and one reference wavelength per measured component. S2500931A is the long wave ZnSe member of the family.

We describe it for buyers who must pick between several near-identical source numbers. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Parameter Value
Part number S2500931A
Type Long wave source, ZnSe
Table 6.3 Source Unit Spares
Located in Source end, right side, on the chopper box
Potted equivalent S2501961A, Long Wave ZnSe (Q-SIL potted)
Short wave option 2552-2204, 10 W halogen lamp
Soft UV option S2520933A, CaF2, 2520 only
Chopper motor S2500986
Chopper thermal fuse 2536-0329, 98 C
Serious fault INFRARED SOURCE FAILURE, SOURCE FAIL

Differences within the source family

  • S2500931A ZnSe, S2500931B BaF2, S2500931C CaF2: three long wave windows in the standard source.
  • S2501961A, B, C: the same three window materials in a Q-SIL potted construction.
  • 2552-2204: replacement short wave 10 W halogen lamp, not a long wave unit.
  • S2520933A: soft ultraviolet CaF2 source for the 2520 only.

The numbers differ in one letter, so a wrong suffix means a wrong optical window. Quote S2500931A exactly.

What a failing source looks like

Diagnostics help find the cause. SOURCE VOLTAGE HIGH and SOURCE VOLTAGE LOW appear in the general fault list with the comment possible Power Control PCB fault, so check S2501911A before blaming the source. INFRARED SOURCE FAILURE is a serious fault and causes shutdown. The chopper motor out of lock fault points instead to the motor or timing, and the thermal fuse 2536-0329 protects the chopper box at 98 degrees Celsius.

Working on the source end safely

Isolate the mains first and, because the 2500 is often in hazardous areas, follow the certified-version rules: the manual notes that for certified versions only the boards listed may be used as spares. Open the right-hand cover on its hinges. A heated cell may exceed 100 degrees Celsius in surface temperature, so allow cooling before touching adjacent parts. Replace the source as a unit, restore the cabling and close the cover.

After fitting S2500931A

Allow the typical two to ten hour warm-up, check the source voltage and the detector signals in the diagnostics, and run a zero and span. If the reference detector signals are less than 50 percent of the initial values after the change, clean the cell.

Related stock

Common companions are the chopper motor S2500986, the fuse kit 02501996 and the power supply S2000925.

Where this unit is used

Long wave sources suit infrared gas measurements in petrochemical, refining and power applications in Oman and the GCC; the application data sheet fixes the optical combination.

Performance facts of the instrument for reference: intrinsic error below plus or minus 1 percent fsd, noise below 1 percent fsd peak to peak at minimum T90, obscuration error below plus or minus 3 percent fsd for 50 percent broadband obscuration of the cell windows, and short term zero drift below plus or minus 1 percent fsd per week for the 2500 model, but below plus or minus 2 percent for the 2520 and 2550. Source intensity indirectly affects all of these.

The recommended spares table lists the source as refer to application, with one for one to three analysers and two for four to nine analysers over two years, and the chopper motor S2500986 as one for any fleet size. Use that guidance as a minimum when planning a shutdown kit.

Optical hygiene matters at the source end too. Keep new parts in their packing until the moment of fitting, avoid touching optical surfaces and make sure the interference filters on the chopper wheel are free from dust. The chopper box has its own scrubbers, listed separately from boss scrubbers, which must not be exposed to ambient air for more than a few minutes.

If you operate several 2500 analysers on a site, standardising on the source window type can simplify stocking, but only the Final Specification Sheet can confirm that it is permissible to change the window material, because the filters, source and detector are designed together. Do not substitute S2500931B or S2500931C for S2500931A without written confirmation of the application data.

The through-beam design needs no alignment after replacing the source, which is one of the advantages the manual highlights for the 2500: the single optical axis means that a source swap is a plug-in task rather than an optical alignment job.

For purchasing, quote S2500931A with its full suffix, confirm ZnSe against the data sheet, and add the analyser serial number. A source swap with S2500931A is normally followed by a short stability check; log the source voltage reading in the diagnostics before and after so you can compare. If the reading is outside the usual range, review the Power Control PCB S2501911A before concluding that S2500931A is faulty. Keep the removed unit tagged until the new S2500931A has run through a warm-up cycle.

Documents and quotation

The Servomex SpectraExact 2500 series manual, part number 02500005D, is the document we attach for Servomex S2500931A; its section 6 spares tables are the source of the part number and description. Please state whether your source is the standard type or the Q-SIL potted type, because the part numbers differ. To request a quotation, send S2500931A, the quantity, the analyser serial number and the Final Specification Sheet reference if you have it, and your delivery location in Oman or the GCC. Each RFQ is answered with availability and lead time.

Other Models in the Servomex 2500 Range

Seven Star LLC supplies models from the Servomex 2500 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Servomex S2500931A Long Wave ZnSe Source Unit for SpectraExact 2500Gas Analyzer SystemsYou are viewing this model
Servomex S2501905C CVDFET Detector Unit for SpectraExact 2500Gas Analyzer SystemsView details
Servomex S2500980B BaF2 Window for SpectraExact 2500Gas Analyzer SystemsView details
Servomex S1200922 CW Boss Scrubber H2O/CO2 for SpectraExact 2500Gas Analyzer SystemsView details
Datasheets & Documents
  • PDF Datasheet Servomex S2500931A Long Wave ZnSe Source Unit for SpectraExact 2500 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Servomex is a British specialist in gas analysis, founded in 1952 by Richard Steel, John Crockett and Ronald Mudie; the name comes from servomechanism. It first made electronic products, then built its first paramagnetic oxygen analyser in 1961 after work with Charles Munday on a paramagnetic sensor. Servomex is based in Crowborough, East Sussex, and is part of Spectris.

Seven Star LLC lists Servomex process, combustion, emissions and portable gas analyzers, plus accessories, and sources them for refineries, petrochemical plants and industrial gas producers in Oman.

SERVOMEX company profile

Founded 1952, United Kingdom
Founders Richard Steel, John Crockett and Ronald Mudie
Headquarters Jarvis Brook, Crowborough, East Sussex
Ownership Spectris plc, since 1999
Key technologies Paramagnetic oxygen sensing (1961), infrared analysis (1969), zirconia oxygen sensors (1981)
Product families MultiExact and SERVOPRO MultiExact analysers, SERVOTOUGH OxyExact and Oxy 1800 oxygen analysers, SERVOTOUGH Laser 3 Plus TDL analysers, SERVOFLEX portable analysers, zirconia combustion analysers

Milestones

  • 1952: Servomex is founded.
  • 1961: The first Servomex paramagnetic oxygen analyser is introduced.
  • 1981: Servomex introduces zirconia oxygen sensors.
  • 1999: Spectris acquires Servomex.

Servomex analyzer families listed

Servomex groups its analyzers under family names that indicate where they can be used. SERVOTOUGH covers analyzers built for hazardous areas and field mounting, SERVOPRO covers units for general purpose areas and analyzer houses, and SERVOFLEX is the portable line. On this page:

  • SERVOTOUGH OxyExact 2200: paramagnetic oxygen analyzer for process control and safety
  • SERVOTOUGH SpectraExact 2500: photometric analyzer for process gas components
  • SERVOTOUGH Laser 3 Plus: compact tunable diode laser analyzer for combustion
  • SERVOPRO 4900 Multigas: multi-component analyzer for emissions monitoring
  • SERVOPRO NanoTrace DF-550E: ultra-trace oxygen analyzer for high purity gases
  • SERVOFLEX Micro i.s. 5100: intrinsically safe portable oxygen analyzer

A flow alarm relay box for the 2700 flue gas analyzer is also listed.

Where Servomex gas analyzers are used

Typical duties are oxygen measurement for inerting and blanketing, vapor recovery and flare header safety, combustion control on fired heaters and reformers, purity control in air separation and electronic gases, and continuous emissions monitoring. In the GCC the main users are refining, petrochemicals, fertilizer, LNG and industrial gas plants.

SERVOMEX products we list

Family Examples
Gas Analyzer Systems SERVOPRO 4900 Multigas Analyzer, SERVOPRO NanoTrace DF-550E Ultra-Trace O…, SERVOTOUGH Laser 3 Plus Combustion TDL G…, SERVOTOUGH OxyExact 2200 Oxygen Analyzer, ServoTough SpectraExact 2500 Gas Analyzer
Portable Test & Measurement Micro i.s. 5100 Portable Oxygen Analyzer
Gas Analyzer Accessories Tough Flue Gas 2700 Flow Alarm Relay Box

Ordering Servomex analyzers and spares: what we need

A Servomex gas analyzer is built to an order code that fixes the measured gas, range, sample wetted materials, outputs and hazardous area approval. For replacements and spare parts, send the model, the serial number and the order code from the data plate. For a new Servomex oxygen analyzer or multigas unit, send the full stream composition, the component and range to be measured, sample pressure and temperature, the area classification, power supply and communication needs. We check the configuration against Servomex documentation before quoting.

Facts checked against Servomex's own 70-year history and company profiles, October 2026.

FAQ

Questions about the Servomex S2500931A Long Wave ZnSe Source Unit for

Answers from our engineering team on installation, compatibility and integration.

01What is Servomex S2500931A?
S2500931A is the long wave ZnSe source unit listed in Table 6.3 Source Unit Spares of the SpectraExact 2500 series manual.
02Where is the source unit located?
In the source end, the right side of the analyser, mounted on the chopper box assembly with the interference filters on a rotating wheel.
03What are the sibling long wave sources?
S2500931C CaF2 and S2500931B BaF2, plus potted Q-SIL versions S2501961A, B and C.
04What fault shows a failed source?
INFRARED SOURCE FAILURE, with log entry SOURCE FAIL, is a serious fault that causes a shutdown.
05Do sources need matching windows?
The Final Specification Sheet defines the source, windows and detector chosen for each analyser.