Brand: SERVOMEX
Servomex S1802989B Solvent Resistant O2 Transducer Oxy 1800
Description
Choosing Servomex S1802989B for solvent-laden samples
Servomex S1802989B is the solvent resistant oxygen transducer assembly for the SERVOTOUGH Oxy 1800 analyser. The quick start manual places it in a separate table titled sample option – solvent resistant / high-flow cell, beside the Hastelloy C-276 tubes kit S1802966 and two high-flow assemblies. The reason it exists is chemical: a paramagnetic cell is a small glass and metal structure with elastomer seals, and some process vapours attack the standard elastomer. S1802989B replaces it with Chemraz, the perfluoroelastomer named in the manual for the solvent tolerant transducer.
Written for maintenance planners and buyers matching a nameplate to a spare. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Materials and what they mean for S1802989B
| Parameter | Value |
|---|---|
| Part number | S1802989B |
| Manual description | Solvent resistant O2 Transducer Assy., 1 off |
| Seal material in contact with sample | Chemraz (solvent tolerant cell); the standard cell uses Viton |
| Other wetted materials | Borosilicate glass, nickel, platinum, platinum/iridium alloy, 316 stainless steel |
| Matching tube kit | S1802966, Hastelloy C-276 inlet and outlet |
| Measurement range | 0.0 – 100.0 percent O2 |
| Repeatability | Less than 0.1 percent of reading or 0.05 percent O2 |
| Linearity error | Less than 0.05 percent O2, inherently linear |
| Span drift | Less than 0.1 percent of reading or 0.05 percent O2 per week |
| Power supply of analyser | 100 to 240 Vac plus or minus 10 percent, 50/60 Hz, 50 VA maximum |
| Ingress protection | IP66 and NEMA 4X |
| Mass | 26 kg |
Note that the analyser model name changes with this option: the older manual states that the xendos 1802 variant is the one to use if the sample is corrosive, and it carries Hastelloy tubes and the 1802 transducer. S1802989B is that transducer family under the newer quick start numbering.
Typical duties for the solvent resistant cell
Think of oxygen monitoring in solvent recovery loops, nitrogen-inerted reactors and storage tank blankets in petrochemical and chemical plants around Sohar, Salalah and the wider GCC, vapour-containing exhaust checks, and packaging lines that flush with inert gas where solvent-based inks are used. In each case the oxygen reading matters for safety or quality, while the carrier gas contains something that would shorten the life of a standard cell.
Do not assume the analyser can be installed in a classified area because the cell is solvent resistant. The manual says plainly that the Oxy 1800 is for a safe non-hazardous area and for non-flammable samples.
How S1802989B differs from S1800989B, S1804989B and S1806989B
- S1800989B uses Viton and is the standard assembly for clean samples.
- S1802989B uses Chemraz and is paired with Hastelloy tubes S1802966; flow window as the base analyser, 50 to 250 ml/min.
- S1804989B is the high-flow cell with a T90 under 5 seconds and a 50 to 70 litres per hour flow window.
- S1806989B is the solvent resistant high-flow cell, so choose it when you need both properties.
Sample handling with S1802989B in service
Because the analyser is chosen for a harsh sample, sample conditioning matters more than usual. Keep particulates below 3 micrometres, hold the sample non-condensing at ambient temperature, and never restrict the vent, which must stay between 11.5 and 18 psia. The manual also recommends the enclosure purge option when the sample is toxic or corrosive, supplied with air or inert gas at 100 to 200 ml per minute and vented freely, and the purge must be running before any cover is opened.
Replacement and recalibration
Swapping the transducer assembly is a workshop-grade service operation covered by service manual 01800002B. Afterwards give the analyser four hours of warm-up before sample gas, zero with nitrogen of 99.9 percent minimum purity, and span with instrument air at 20.9 percent O2. The calibration should be checked weekly, monthly or every three months depending on the application. If the oxygen content of the sample is above 21 percent, use a certified calibration gas, not air.
Keeping S1802989B and related spares on the shelf
A solvent-exposed transducer is a consumable in practice, so sites often hold one S1802989B per critical analyser together with a tube kit S1802966 and the common fuse and seal kits. Ask us to quote the full set if you are preparing a turnaround.
Electrical and output behaviour of an analyser carrying S1802989B
The transducer feeds the housekeeping board, which drives two linear outputs at once: an isolated 4-20 mA signal, never above 22 mA, into a load of up to 600 ohms, and a non-isolated 0-1 Vdc signal with a typical output impedance of 470 ohms. Both follow the range chosen by the front panel push button or the link settings, selectable from 0-2.5, 5, 10, 25 and 100 percent O2. If the sample flow alarm option detects a low flow, the failure mode link decides whether the current output goes to 0 mA or above 20 mA; with the solvent resistant cell this is a useful way to flag a blocked line before contaminated gas lingers in the cell.
Two concentration alarms, configurable as high or low, and a flow-fail relay are rated 250 Vac at 3 A or 28 Vdc at 1 A, non-inductive, with a 5 V and 10 mA minimum. Relays are drawn in the de-energised position and also change state on power failure, so a failed supply is visible in the control room.
Questions procurement should settle before ordering S1802989B
- Is the analyser serial number the Oxy 1800 type with a Chemraz cell, or a standard Viton cell?
- Is the sample flow in the 50 to 250 ml/min range, or does it belong to the high-flow family?
- Are Hastelloy tubes already fitted, meaning S1802966 is not required?
- Is the oxygen level above 21 percent, requiring a certified span gas for later calibration?
Documents and quotation
The Servomex SERVOTOUGH Oxy 1800 quick start manual, part number 01800003B revision 4, is the document we attach for Servomex S1802989B; it carries the spares table, the sample condition table and the performance figures quoted on this page. Tell us the solvent species in your sample so we can confirm that you need the solvent resistant assembly rather than the standard one. To request a quotation, send the part number S1802989B, the quantity, the analyser serial number if you have it, and the delivery location in Oman or elsewhere in the GCC. We reply to each RFQ with availability and lead time.
Other Models in the Servomex Oxy1800 Range
Seven Star LLC supplies models from the Servomex Oxy1800 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Servomex S1806989B Solvent Resistant High-Flow O2 Transducer | Gas Analyzer Systems | View details |
| Servomex S1802989B Solvent Resistant O2 Transducer Oxy 1800 | Gas Analyzer Systems | You are viewing this model |
| Servomex S1800989B Standard O2 Transducer for Oxy 1800 | Gas Analyzer Systems | View details |
| Servomex S1804989B High-Flow O2 Transducer for Oxy 1800 | Gas Analyzer Systems | View details |
| Servomex S1800912A 4.5 Digit Display PCB for Oxy 1800 | Gas Analyzer Systems | View details |
| Servomex S1802966 Hastelloy C-276 Sample Tubes Kit Oxy 1800 | Gas Analyzer Systems | View details |
Datasheets & Documents
- Datasheet Servomex S1802989B Solvent Resistant O2 Transducer Oxy 1800 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Servomex is a British specialist in gas analysis, founded in 1952 by Richard Steel, John Crockett and Ronald Mudie; the name comes from servomechanism. It first made electronic products, then built its first paramagnetic oxygen analyser in 1961 after work with Charles Munday on a paramagnetic sensor. Servomex is based in Crowborough, East Sussex, and is part of Spectris.
Seven Star LLC lists Servomex process, combustion, emissions and portable gas analyzers, plus accessories, and sources them for refineries, petrochemical plants and industrial gas producers in Oman.
SERVOMEX company profile
| Founded | 1952, United Kingdom |
|---|---|
| Founders | Richard Steel, John Crockett and Ronald Mudie |
| Headquarters | Jarvis Brook, Crowborough, East Sussex |
| Ownership | Spectris plc, since 1999 |
| Key technologies | Paramagnetic oxygen sensing (1961), infrared analysis (1969), zirconia oxygen sensors (1981) |
| Product families | MultiExact and SERVOPRO MultiExact analysers, SERVOTOUGH OxyExact and Oxy 1800 oxygen analysers, SERVOTOUGH Laser 3 Plus TDL analysers, SERVOFLEX portable analysers, zirconia combustion analysers |
Milestones
- 1952: Servomex is founded.
- 1961: The first Servomex paramagnetic oxygen analyser is introduced.
- 1981: Servomex introduces zirconia oxygen sensors.
- 1999: Spectris acquires Servomex.
Servomex analyzer families listed
Servomex groups its analyzers under family names that indicate where they can be used. SERVOTOUGH covers analyzers built for hazardous areas and field mounting, SERVOPRO covers units for general purpose areas and analyzer houses, and SERVOFLEX is the portable line. On this page:
- SERVOTOUGH OxyExact 2200: paramagnetic oxygen analyzer for process control and safety
- SERVOTOUGH SpectraExact 2500: photometric analyzer for process gas components
- SERVOTOUGH Laser 3 Plus: compact tunable diode laser analyzer for combustion
- SERVOPRO 4900 Multigas: multi-component analyzer for emissions monitoring
- SERVOPRO NanoTrace DF-550E: ultra-trace oxygen analyzer for high purity gases
- SERVOFLEX Micro i.s. 5100: intrinsically safe portable oxygen analyzer
A flow alarm relay box for the 2700 flue gas analyzer is also listed.
Where Servomex gas analyzers are used
Typical duties are oxygen measurement for inerting and blanketing, vapor recovery and flare header safety, combustion control on fired heaters and reformers, purity control in air separation and electronic gases, and continuous emissions monitoring. In the GCC the main users are refining, petrochemicals, fertilizer, LNG and industrial gas plants.
SERVOMEX products we list
Ordering Servomex analyzers and spares: what we need
A Servomex gas analyzer is built to an order code that fixes the measured gas, range, sample wetted materials, outputs and hazardous area approval. For replacements and spare parts, send the model, the serial number and the order code from the data plate. For a new Servomex oxygen analyzer or multigas unit, send the full stream composition, the component and range to be measured, sample pressure and temperature, the area classification, power supply and communication needs. We check the configuration against Servomex documentation before quoting.
Facts checked against Servomex's own 70-year history and company profiles, October 2026.
Browse SERVOMEX products by category: Gas Analyzer Systems, Gas Analyzer Accessories, Portable Test & Measurement.
FAQ
Questions about the Servomex S1802989B Solvent Resistant O2 Transducer
Answers from our engineering team on installation, compatibility and integration.
01What does Servomex S1802989B replace?
S1802989B is the solvent resistant O2 transducer assembly in the xendos 1800 sample option for solvent resistant and high-flow cells, for analysers built with the Chemraz-sealed measuring cell.
02Why is S1802989B different from the standard transducer?
The manual lists Chemraz in contact with the sample for the solvent tolerant transducer, where the standard S1800989B uses Viton, so S1802989B tolerates solvent vapours that would swell Viton.
03Which tube kit goes with S1802989B?
The manual lists S1802966, the Hastelloy C-276 sample inlet and outlet tubes kit, in the same solvent resistant table, for corrosive samples.
04Is S1802989B suited to hazardous areas?
No. The Oxy 1800 is for safe areas and non-flammable samples; flammable or hazardous duties are directed to the 1900 series.
05What flow range does the base analyser with this cell accept?
The performance table gives 50 to 250 ml/min for the base analyser, with a flow effect of less than 0.1 percent O2; the high-flow cells are specified separately.