Brand: Magnetrol
Magnetrol Z30-9166-004 Fieldbus Wiring Board for Pulsar R86,
Description
Magnetrol Z30-9166-004 overview: wiring board for the Pulsar Model R86
The Magnetrol Z30-9166-004 is the replacement fieldbus wiring PC board for the Pulsar Model R86 with non-sparking classification. The manual lists it for FOUNDATION fieldbus or PROFIBUS PA units (5th digit 2 or 3) whose 8th digit is C (non-sparking, ATEX). Maintenance planners search for this exact number because the Pulsar Model R86 is built in many variants, and a board or module for the wrong variant can leave a level or flow loop out of service during a shutdown window.
The picture on this page is the manufacturer product image for the Pulsar Model R86 26 GHz non-contact radar level transmitter, which is the family that uses the Z30-9166-004. It is not a close-up of the wiring board itself. Every value below comes from the manufacturer manual 58-603 and catalog pages for that family, and where a value is not published for this specific part we have left it out instead of guessing.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list Z30-9166-004 so that buyers can quote the number exactly as printed in the manual, and we confirm availability against your quotation request.
Key features of Z30-9166-004
- Exact manufacturer part number Z30-9166-004, shown in the replacement parts section of manual 58-603.
- Function: wiring PC board for the Pulsar Model R86, selected by the model number digits printed on the transmitter nameplate.
- Fits the Pulsar Model R86 26 GHz non-contact radar level transmitter, which the manufacturer describes as follows: The R86 is a through-air pulse burst radar transmitter that works at 26 GHz. It measures level from the time of flight of the radar pulse reflected by the product surface, and the manufacturer publishes a span of 0.5 to 130 feet (0.2 to 40 meters).
- Replacing a plug-in or board-level part can restore a loop without replacing the whole instrument, which keeps process piping, flanges and the probe or antenna untouched.
- The manual advises that the nameplate model and serial number should always be quoted when spare parts are ordered.
Z30-9166-004 technical specifications
| Parameter | Value |
|---|---|
| Manufacturer | Magnetrol (AMETEK) |
| Part number | Z30-9166-004 |
| Part type | Wiring PC board |
| Used in | Pulsar Model R86 26 GHz non-contact radar level transmitter |
| Measurement principle | Pulse burst radar, 26 GHz |
| Span | 0.5 to 130 ft (0.2 to 40 m) |
| Output options | 4 to 20 mA with HART (3.8 to 20.5 mA usable per NAMUR NE 43), FOUNDATION fieldbus H1, PROFIBUS PA |
| Loop resistance, HART | 591 ohms (general purpose and IS) or 500 ohms (explosion-proof and flameproof) at 24 VDC and 22 mA |
| Accuracy | 0.1 in (3 mm) or 0.1 percent of tank height, whichever is greater |
| Safety option | SIL 2 hardware, HART only, safe failure fraction 93.2 percent |
| Ambient temperature | -40 to +175 F (-40 to +80 C) general purpose; -40 to +158 F (-40 to +70 C) agency approved |
| Housing | IP67 die-cast aluminum, stainless steel optional |
| Cable entry | 1/2 inch NPT or M20 |
The family values in the table describe the instrument that the Z30-9166-004 belongs to and are quoted from manual 58-603. The Z30-9166-004 itself is a replacement part and carries the model-code rules summarized in the selection section below.
Typical applications for the Pulsar Model R86 and Z30-9166-004 in Oman and the GCC
Instruments of this family are used in storage tanks and day tanks in refineries and tank farms, sumps and wet wells in water and wastewater plants, chemical dosing vessels, process vessels in manufacturing and utility boiler make-up water tanks. In Oman and across the GCC these duties appear in oil and gas production and processing, petrochemical and fertilizer plants, power and desalination stations, municipal water and wastewater works, and general manufacturing.
Typical reasons to buy a spare such as the Z30-9166-004 are a failed board after a lightning surge or moisture ingress, a unit that has reached the end of service life, or a plant that wants a spare on the shelf for critical tags instead of waiting for a long lead time during an outage.
Selection and compatibility notes for Z30-9166-004
The manual lists it for FOUNDATION fieldbus or PROFIBUS PA units (5th digit 2 or 3) whose 8th digit is C (non-sparking, ATEX). Always compare the full model number on the nameplate with the manual before ordering, because boards for different outputs, approvals and housings are not interchangeable.
- Read the 5th and 6th digits of the model number first. They set the output and safety option and decide which electronics are fitted.
- Read the classification digit next. Explosion-proof, flameproof, intrinsically safe and non-sparking versions can use different boards.
- Confirm the display and housing digits if the part is a display, cover or housing-related item.
- Send the serial number with the RFQ so the part can be checked against the configuration of the instrument.
If you are unsure whether Z30-9166-004 is right for your tag, send us the nameplate photo and we will compare it with the parts list before quoting. The manual also names related spares for this family, including Z31-2864-001 electronic module, Z31-2864-002 electronic module for fieldbus, Z31-2873-001 electronic module for PROFIBUS PA, Z30-9180-001 and Z30-9180-002 HART wiring boards, Z31-2865-001 HART wiring board, Z30-9166-003 and Z30-9166-004 fieldbus wiring boards, and heat extension 032-6922-001.
Installation and commissioning with Z30-9166-004
The radar antenna looks straight down, so the nozzle height, antenna extension and any internal obstructions should be checked against the manufacturer guidance before a replacement board is fitted. Make the loop safe and remove power, open the correct compartment cover, and note the existing configuration because the transmitter holds echo and tank parameters in its own electronics.
Follow the safety instructions of the manufacturer manual 58-603 for the hazardous area classification of the installation. In classified areas do not open housings while the circuit is live unless the area is known to be non-hazardous, and re-fit all covers and O-rings fully before power is restored. After fitting the Z30-9166-004, record the date, the tag and the part number in the maintenance log.
Maintenance and spare strategy
Keep the antenna face clean and dry, inspect the O-ring (manufacturer part 012-2601-237) every time a cover is opened, and keep a record of the echo curve captured at commissioning so that later drift or buildup can be compared against a known good reference.
For critical level and flow measurements many plants keep one wiring board such as the Z30-9166-004 per instrument family on site. This shortens repair time because the technician only has to swap the part and reload the configuration instead of waiting for a complete replacement transmitter.
Related products and ordering notes for Z30-9166-004
Other spares in the same family that buyers often request together with Z30-9166-004 include Z31-2864-001 electronic module, Z31-2864-002 electronic module for fieldbus, Z31-2873-001 electronic module for PROFIBUS PA, Z30-9180-001 and Z30-9180-002 HART wiring boards, Z31-2865-001 HART wiring board, Z30-9166-003 and Z30-9166-004 fieldbus wiring boards, and heat extension 032-6922-001. These are listed in the manufacturer manual under replacement parts, and we can quote them in the same RFQ.
For each line please state the part number, the quantity, the tag number and the delivery location in Oman or the GCC. We will confirm availability and lead time and return a written quotation.
FAQ summary
- What is the Magnetrol Z30-9166-004? The Z30-9166-004 is the replacement fieldbus wiring PC board for the Pulsar Model R86 with non-sparking classification. It is listed in the replacement parts section of the manufacturer manual 58-603.
- Which instrument uses the Z30-9166-004? It is listed for the Pulsar Model R86 26 GHz non-contact radar level transmitter. The manual lists it for FOUNDATION fieldbus or PROFIBUS PA units (5th digit 2 or 3) whose 8th digit is C (non-sparking, ATEX).
- How do I confirm that Z30-9166-004 matches my instrument? Compare the model number digits on the nameplate with the parts list in manual 58-603 and send us the model and serial number with your RFQ so we can confirm the part number before quoting.
- Can Seven Star LLC supply Z30-9166-004 in Oman? Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with Z30-9166-004, the quantity and the delivery location and we will confirm availability.
- Is documentation available for Z30-9166-004? Yes. The manufacturer manual 58-603 with the replacement parts list is available from this page as a datasheet download, and the nameplate data of your unit should always be checked against it.
Documents and quotation
The manufacturer manual 58-603 for the Pulsar Model R86 is attached to this page as the datasheet for Z30-9166-004. It contains the replacement parts list, model number tables, wiring diagrams and specifications referred to above. To request a quotation, send the RFQ with the part number Z30-9166-004, the quantity, the instrument tag and the nameplate model and serial number. Seven Star LLC will reply with availability and lead time for Oman and the GCC.
Other Models in the Magnetrol R86 Range
Seven Star LLC supplies models from the Magnetrol R86 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Magnetrol Z31-2864-001 Electronic Module for Pulsar R86 Radar | Radar & Guided Wave Radar Level | View details |
| Magnetrol 032-6922-001 Heat Extension for Pulsar R86 Antenna | Radar & Guided Wave Radar Level | View details |
| Magnetrol Z31-2864-002 Electronic Module for Pulsar R86 Fieldbus | Radar & Guided Wave Radar Level | View details |
| Magnetrol Z31-2873-001 Electronic Module for Pulsar R86 PROFIBUS PA | Radar & Guided Wave Radar Level | View details |
| Magnetrol Z31-2865-001 HART Wiring Board for Pulsar R86, XP/Flameproof | Radar & Guided Wave Radar Level | View details |
| Magnetrol Z30-9180-002 HART Wiring Board for Pulsar R86, Non-Sparking | Radar & Guided Wave Radar Level | View details |
| Magnetrol Z30-9166-003 Fieldbus Wiring Board for Pulsar R86 and R96 | Radar & Guided Wave Radar Level | View details |
| Magnetrol Z30-9166-004 Fieldbus Wiring Board for Pulsar R86, | Radar & Guided Wave Radar Level | You are viewing this model |
Datasheets & Documents
- Manual Magnetrol Z30-9166-004 Fieldbus Wiring Board for Pulsar R86, Manual with Parts List Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.
Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.
Magnetrol company profile
| Established | 1932, USA; headquarters in Aurora, Illinois |
|---|---|
| Ownership | Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group |
| Product families | Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand) |
| Applications | Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection |
Milestones
- 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
- 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
- 2021: AMETEK acquires Magnetrol on 29 March.
Magnetrol products we list
| Model | Principle | Typical use |
|---|---|---|
| Eclipse 706 | Guided wave radar | Level and interface in separators, chambers and boiler drums, unaffected by changing density |
| Pulsar R80 | 80 GHz FMCW radar | Narrow-beam non-contact level in tanks with internals and in solids |
| Pulsar R86 | 26 GHz radar | Non-contact level in process and storage vessels |
| Pulsar R96 | 6 GHz radar | Non-contact level where vapour, foam or condensation are present |
| E4 Modulevel | Displacer | Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units |
| Echotel 961/962 | Ultrasonic gap switch | High and low level alarms and pump protection |
| Thermatel TD1/TD2 | Thermal dispersion switch | Flow and no-flow detection and level switching for liquids and gases |
Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don't affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.
Where Magnetrol instruments are used
In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.
Ordering Magnetrol instruments: what we need
Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.
Facts checked against Magnetrol and AMETEK company information, October 2026.
Browse Magnetrol products by category: Level Transmitter.
FAQ
Questions about the Magnetrol Z30-9166-004 Fieldbus Wiring Board for
Answers from our engineering team on installation, compatibility and integration.
01What is the Magnetrol Z30-9166-004?
The Z30-9166-004 is the replacement fieldbus wiring PC board for the Pulsar Model R86 with non-sparking classification. It is listed in the replacement parts section of the manufacturer manual 58-603.
02Which instrument uses the Z30-9166-004?
It is listed for the Pulsar Model R86 26 GHz non-contact radar level transmitter. The manual lists it for FOUNDATION fieldbus or PROFIBUS PA units (5th digit 2 or 3) whose 8th digit is C (non-sparking, ATEX).
03How do I confirm that Z30-9166-004 matches my instrument?
Compare the model number digits on the nameplate with the parts list in manual 58-603 and send us the model and serial number with your RFQ so we can confirm the part number before quoting.
04Can Seven Star LLC supply Z30-9166-004 in Oman?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with Z30-9166-004, the quantity and the delivery location and we will confirm availability.
05Is documentation available for Z30-9166-004?
Yes. The manufacturer manual 58-603 with the replacement parts list is available from this page as a datasheet download, and the nameplate data of your unit should always be checked against it.