Iskra IE14MD Single-Phase Energy Meter 40 A, MID, Modbus
Description
IE14MD is the top variant of the Iskra IE14xx series of single-phase meters: a 17.5 mm wide, DIN-rail meter for currents up to 40 A with MID class B approval, RS485 Modbus, an IR port, NFC and a 70 C ambient rating. It is a compact choice for sub-metering single-phase loads.
One DIN module, full communication
The IE14MD measures energy directly in two-wire networks and calculates power (active, reactive, apparent), voltage, current, frequency, power factor, power angle and THD of voltage and current. Energy is bidirectional, with class 2 reactive energy and up to four tariffs managed over communication.
The manual lists five types in the series. The IE14-S has an S0 output and no MID approval; the IE14MS adds MID and a touch button; the IE14MN adds IR and NFC; the IE14MM adds M-Bus; and the IE14MD swaps the pulse output for Modbus, with the 70 C display rating that is unique to the IE14MD. A limit control function can send an alarm and trigger a BICOM bistable switch through the side IR port.
Features stated in the data sheet
- Single-phase direct connection, Imax 40 A, basic current 5 A, 230 V rated voltage.
- Class 1 active energy (EN 62053-21) with MID class B (EN 50470-3); class 2 reactive energy.
- Custom LCD with seven digits at 100 Wh resolution, backlight, capacitive touch button.
- IR, RS485 Modbus RTU and NFC for set-up and read-out.
- 1 DIN module width; sealable terminal cover.
Technical specification
Electrical data
| Parameter | Specification |
|---|---|
| Rated voltage | 230 V (-20 % to +15 %); 50 and 60 Hz |
| Current | Iref 5 A; Imax 40 A; Imin 0.25 A; Itr 0.5 A; starting 20 mA |
| Active energy accuracy | Class 1; class B: ±1.5 % Imin to Itr, ±1 % Itr to Imax |
| Reactive and apparent energy | Class 2: ±2.5 % Imin to Itr, ±2 % Itr to Imax |
| Voltage / frequency accuracy | ±1 % of measured value / ±0.1 % |
| Power consumption | below 10 VA at Un; below 0.1 VA at Iref |
| LED | red, 1000 imp/kWh; indicates no load |
Interfaces, mechanics and environment
| Parameter | Specification |
|---|---|
| RS485 | Modbus RTU, 1200 – 115200 bit/s, galvanically isolated |
| IR port | Modbus RTU via USB adapter, 19200 bit/s, 8N2, address 33, fixed settings |
| NFC | ISO/IEC 14443, 13.56 MHz, 106 kbps, up to 15 mm from the LCD |
| Size / weight | 17.5 x 90.7 x 68.2 mm; 150 g (170 g packed); 35 mm DIN rail |
| Terminals | 1.5 to 10 mm2, M3.5 screws, 0.8 to 0.9 Nm; auxiliary 0.25 to 1 (2.5) mm2 |
| Ambient range | -25 to +70 C for IE14MD (+55 C for other types); storage -30 to +70 C; IP50 |
| Safety | Protection class II; 300 V CAT III; pollution degree 2 |
Ordering codes in the series
The data sheet gives five article numbers: 022433925000 IE14-S, 022433925100 IE14MS (S0, MID), 022433925200 IE14MN (S0, IR, NFC, MID), 022433925300 IE14MM (M-Bus, IR, NFC, MID) and 022433925400 IE14MD (RS485 Modbus, IR, NFC, 70 C range, MID).
For a PLC or gateway network choose IE14MD. For utility-style M-Bus readers choose IE14MM. Where only a pulse is needed, the MN or MS types are simpler.
Installation notes
The manual allows DIN-rail mounting only. Switch off at the main fuse or breaker, check that no voltage is present and prevent accidental switch-on. A 40 A fuse is recommended for line protection, and the neutral must be connected. Stranded wire needs 12 mm ferrules with 14 mm stripped insulation.
Fit plastic security seals only, as the manual specifies. At power-up the capacitive touch sensor calibrates itself, so keep the front free of contact for a moment. After a minute without touch, the display returns to automatic cycling; the hold page function can keep one screen visible even after a power-down.
Typical applications
General engineering note: this class of meter is used to record consumption of single-phase loads such as air-conditioning units, lighting boards, small workshops, rented units and site cabins. Modbus read-out allows the energy data to be collected by a building or plant energy system.
A current rating of 40 A applies; larger loads need a CT-connected meter.
Related Iskra items
The WM1-6 is a 65 A single-phase meter with optional modules, and the IE38MD is the 80 A three-phase counterpart. Browse the power meters category for other models.
Sub-metering in Oman and the GCC
Single-phase DIN-rail meters are used in the region for metering apartments, shops and offices in mixed-use buildings, for sub-metering lighting, small pumps and air conditioning units, and for small solar or charging circuits. The 17.5 mm width helps when distribution boards are already full. The Modbus output allows a building management system to read energy and power without separate transducers. Check the panel’s internal temperature in summer, and where readings are used to bill tenants, confirm which approvals the local authority requires.
Information to send with an enquiry
- Variant needed in the IE14 series
- Number of meters and the communication network
- Whether MID approval is required
Frequently asked questions
How does IE14MD differ from IE14MM?
The IE14MM uses M-Bus; the IE14MD uses RS485 Modbus and is the only type with the 70 C range. Both are MID approved with IR and NFC.
What is the maximum current?
40 A with 5 A reference current; minimum current is 0.25 A.
Is the IE14MD suitable for 70 C ambient?
The data sheet states a 70 C ambient operating range valid only for the IE14MD; other types are rated to 55 C.
How wide is the meter?
It is one DIN module, 17.5 mm wide, 90.7 mm high and 68.2 mm deep.
Does Seven Star LLC act as an Iskra distributor?
No, we are an independent supplier in Muscat and supply Iskra items on request rather than acting as a Iskra channel partner.
Documents and quotation
Need IE14MD? The Iskra datasheet and user manual are attached to this listing. Seven Star LLC (independent supplier, Muscat) can quote the item and arrange supply on request; list quantity and site location in your enquiry. Verify the order code and electrical options in the documents before ordering. Other products are in the category page.
Datasheets & Documents
- Datasheet Iskra IE14xx single-phase energy meters data sheet, version 1.10, EN P22.433.925 (PDF) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Iskra is a Slovenian electrical and electronics company from Kranj, whose name, meaning spark, was given to the former Kranj machine works in 1946. Its measurement range covers power quality analysers, multifunction meters and MID energy meters. After Yugoslavia broke up, Iskra's businesses were split into separate companies; the utility electricity meter maker Iskraemeco is one of them.
Iskra company profile
| Name given | 1946, Kranj, Slovenia |
|---|---|
| Origin | Kranj, Slovenia |
| Related company | Iskraemeco (utility electricity meters) |
| Product families | iMC Class A power quality analysers, iMC multifunction meters and network recorders, MID three-phase energy meters with Modbus, EV charging meters, current transformers, multimeters |
Milestones
- 1946: The Kranj works is renamed Iskra.
- 1990s: Iskra's businesses become separate companies.
Energy meters and power monitoring devices
The Iskra measuring range includes iMC multifunction meters, network recorders and Class A power quality analyzers for panel mounting, single-phase and three-phase DIN-rail energy meters of the IE and WM series with MID approval, analogue panel meters, portable multimeters and hour meters. Each data sheet lists accuracy classes, communication options, dimensions and ordering codes.
Supply through Seven Star LLC
Seven Star LLC is an independent supplier in Muscat that quotes Iskra products for projects in Oman and the GCC, with the official Iskra data sheet attached to each product page.
Iskra products we list
Facts checked against published Iskra company histories and registry entries, October 2026.
Related products
Frequently Asked Questions
The IE14MM uses M-Bus; the IE14MD uses RS485 Modbus and is the only type with the 70 C range. Both are MID approved with IR and NFC.
40 A with 5 A reference current; minimum current is 0.25 A.
The data sheet states a 70 C ambient operating range valid only for the IE14MD; other types are rated to 55 C.
It is one DIN module, 17.5 mm wide, 90.7 mm high and 68.2 mm deep.
No, we are an independent supplier in Muscat and supply Iskra items on request rather than acting as a Iskra channel partner.

Reviews
There are no reviews yet.