- Industrial Communications
- AC Drives
- Vibration Monitoring
- PLC & I/O Cards
- Automation Accessories
- Controllers & Data Acquisition
- CCTV & Security
- Encoders
- Industrial Computers
- Safety Switches & Guard Locking
- HMI Displays
- Motor Soft Starters
- Isolator & Barrier
- Pneumatic Cylinders
- Servo Drives
- Automation Software
- Robotics
- Machine Vision
Brand: Rheonik
Rheonik RHE21 Ex d Field Mount Mass Flow Transmitter
Description
An explosion-proof brain for Rheonik Coriolis sensors
The Rheonik RHE21 is a multifunction mass flow transmitter in a flameproof stainless steel housing, intended for general and critical process flows, feed stock transfers, custody transfer, well head production and offshore work. It converts the signals of any Rheonik Coriolis sensor into mass flow, volume, density and temperature, with positive, negative and net totalizers for both mass and volume. A backlit colour display and three behind-glass buttons give local access without opening the housing.
Because the enclosure is Ex d, the transmitter can be mounted in the hazardous area itself, which shortens the sensor cable to 3 m or 10 m, or runs to an intrinsically safe terminal box for a custom cable length.
Features from the datasheet
- Wall or pipe bracket mounting; SS316 corrosion-resistant housing available.
- Advanced functions: Net Oil, Baume/Brix, percent solids, standard density and standard volume to API MPMS Chapter 11.
- Assurance View diagnostics with the Assurance Factor value and colour-changing display.
- Password-protected setup and upload/download of configuration files.
- USB connection for a PC running RHECom software (Free, Pro and Pro+ versions).
Technical specification
| Parameter | Specification |
|---|---|
| Enclosure | Stainless steel, optionally all 316L; IP66 / NEMA 4X |
| Ambient temperature | -40 to +60 C (display visibility reduced below -20 C) |
| Size and weight | About 255 x 200 x 100 mm; 8 kg (17.5 lb) |
| Display | Backlit colour LCD that changes colour on warning or error; 3 capacitive buttons |
| Sensor connection | Integral cable of 3 m or 10 m, or optional IS terminal box for custom length |
| Analog outputs | Up to 2 x 4-20 mA, active or passive; uncertainty +/-0.1% of reading +/-10 uA; NAMUR NE43 |
| Pulse / frequency / status | Up to 2 configurable outputs, maximum 10 kHz |
| Digital outputs and inputs | Up to 2 status outputs and up to 2 control inputs (IEC 60946) |
| Analog input (optional) | 1 x 4-20 mA active, for two-wire pressure or density sensor |
| Communications | Modbus RTU (RS485), HART over analog output, USB to PC |
| Power supply | 100-240 VAC (48 to 62 Hz), 5 W and/or 12-24 VDC +/-10%, 4 W; typical consumption 3 to 4 W |
| Cable entries | Type E: two M16 x 1.5 with Ex e glands; H types: two 1/2 in NPT; options 1/2, 3/4 in NPT, M20, M25 |
Choosing the software package
Five packages build on each other. SO provides mass flow, temperature, fixed and calculated density, batch control and diagnostics. DO adds live density, volume from measured density and Brix/Baume units. AF adds the Assurance Factor, a PID controller for the analog output and partly filled pipe management. GV brings API standard density and volume, Net Oil and concentration calculations. CT adds the hardware lock switch for sealing. The Fluid Transfer package also offers Precision Flow Analysis, which raises the update time to 4 ms for fast-fill measurements as short as 0.5 s.
Ordering and housing codes
Housing codes are E3 and E4 (SS 316L Ex d(e), wall or hook, with 3 m or 10 m cable), EP (panel mount, 10 m cable), E5 (two terminal boxes) and H1 to H3 (stainless Ex d with 1/2 in NPT entries). Power codes are D1, A1 and U1. I/O codes include S1, S2, P1, P2, SH, PH and CH, where H adds HART and CH also adds the analog input. Approval codes are AS, A2, A1, CS, C2 and C1, printed with their Ex markings in the datasheet. Cable entries can be changed to NPT or M20 variants.
Approval markings as printed
The datasheet prints the labelling for each code. A1 (Zone 1, 2) carries ATEX II 2(1)G Ex db eb [ia Ga] IIC T4 Gb and the matching IECEx marking; A2 (Zone 2) carries II 3(1)G Ex db ec [ia Ga] IIC T4 Gc; AS is the safe-area associated equipment code [Ex ia Ga] IIC. For North America, C1 is Class I, Div. 1, 2 (Zone 1, 2) with Ex db [ia Ga] IIC T4 Gb, C2 is Class I, Div. 2 (Zone 2) and CS is the safe-area associated equipment code. Where a sensor and the transmitter are installed in different zones the intrinsically safe sensor circuit is what links them, so verify both labels for your exact configuration.
Practical notes
Sensor and transmitter must carry matching approvals for the installation zone. The dual supply option lets the transmitter run from AC when present and from DC, including a battery, if AC fails. The datasheet notes that tamper-proof seals can be applied once the lock switch is set. RHECom Free allows full setup and data logging at no cost; Pro and Pro+ add trending and a simulator.
Use in oil and gas
Wellhead, production manifolds, offshore decks and loading terminals in the Gulf are typical locations for an explosion-proof flow computer with built-in API volume corrections.
Selection and installation notes
A mass flow transmitter must match the sensor it is connected to, so confirm the sensor model, the cable length, the supply voltage, the output types and the area classification before ordering. Keep the signal cable away from power cables, ground the shield as described in the manual, protect the housing from direct heat and water ingress and record the calibration factors and zero values at commissioning. Use the correct cable glands and seals, particularly in hazardous areas.
Information needed for a quotation
Send the full model code, the quantity, the delivery location in Oman or the GCC, the intended use and any accessories needed, so that the complete package can be quoted together.
Documents and supply information
The manufacturer data sheet is attached to this page and should be read together with the project specification and the site risk assessment before a purchase is confirmed. Ratings, standards and dimensions are quoted as printed on that sheet. Lead time, stock position and certificates available with the shipment are confirmed in the quotation, and we supply to Oman and the wider GCC region for industrial, utility and building services projects.
Related items
Compatible sensors are the Rheonik RHM series; see flow and process measurement for related equipment. Send the sensor model, zone and signal needs and we will quote; confirm the full part number before ordering.
Datasheets & Documents
- Datasheet Rheonik RHE21 Ex d field mount transmitter datasheet (version 1.6, May 2026) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Rheonik designs and manufactures Coriolis mass flow meters and the transmitters that drive them, with its head office in Odelzhausen, Germany, where it was founded in 1986. Its meters measure mass flow, density and temperature directly, independent of fluid properties.
Seven Star LLC is an independent supplier in Muscat. We list Rheonik sensors and transmitters with their official datasheets for oil and gas, petrochemical, chemical and filling applications in Oman and the GCC.
Rheonik product series
RHM sensors on this site cover a wide range of sizes: the RHM06 for about 36 kg/min, the RHM20 for 480 kg/min, the RHM40 for 1500 kg/min, the RHM100 for 12,000 kg/min and the RHM160 for 30,000 kg/min. Tube materials, pressure ratings and process connections are chosen through the order code.
RHE transmitters include the RHE21 Ex d field mount transmitter, the RHE42 all-digital field transmitter, the RHE28 universal mount transmitter and the compact RHE26 and RHE46 units for panel or DIN rail mounting.
Where Rheonik meters are used
Custody transfer and loading of hydrocarbons, chemical injection and dosing, high-pressure gas and hydrogen measurement, batching and filling, and measurement of viscous or hot fluids.
Ordering Rheonik meters: what we need
Give the fluid, flow range, line pressure and temperature, process connection and hazardous area class. Sensor and transmitter approvals must match, so we confirm the full order code for both before ordering.
Browse Rheonik products by category: Flowmeters.
Related products
Frequently Asked Questions
A stainless steel Ex d enclosure (optionally all 316L) rated IP66 / NEMA 4X for ambient temperatures from -40 to +60 C.
Up to two 4-20 mA outputs, two pulse/frequency/status outputs to 10 kHz, two status outputs, Modbus RTU, HART over the analog output and USB for the RHECom software.
100-240 VAC (A1), 12-24 VDC (D1) or a dual supply (U1) that switches to DC if AC fails.
The CT package adds a hardware lock switch and seal point; Fluid Transfer or Custody Transfer functions include Precision Flow Analysis for fast fills.
Approval codes AS, A2, A1, CS, C2 and C1 cover ATEX/IECEx and cCSAus options; the transmitter and sensor approvals must match.

Reviews
There are no reviews yet.