Brand:

ABB ACS580-01-039A-4 AC Drive 18.5 kW 38 A

Description

ACS580-01-039A-4 at a glance

Looking for a 18.5 kW ACS580 on a 400 V network? ACS580-01-039A-4 is the catalogue type: 38 A nominal output, frame R3, wall mounting and a base of 203 x 229 mm. An 18.5 kW motor is a regular size for centrifugal pumps and fans on utility skids, and this type has 38 A of nominal current inside the R3 housing.

It belongs to the ACS580-01 line that ABB describes as a drive for compressors, conveyors, pumps, extruders, centrifuges, mixers and fans. Choke, EMC filter, Modbus RTU and Safe Torque Off are built in, and the assistant control panel is delivered with the unit. Other ratings sit in the AC drives category, and the series overview is on the ABB ACS580 drive page.

Technical specifications

Parameter Specification
Type designation ACS580-01-039A-4
Series / construction ACS580 / 01 = wall-mounted
Supply voltage 3-phase, 380 to 480 V (code 4)
Frame size R3
Nominal rating (no overload) 18.5 kW, 38 A at 400 V
Light-duty use at 400 V 36.1 A, 18.5 kW (110% for 1 min every 10 min)
Heavy-duty use at 400 V 31.6 A, 15 kW (150% for 1 min every 10 min)
Maximum output current 56.9 A for 2 s at start
Ratings at 480 V Light duty 34 A / 25 hp, heavy duty 27 A / 20 hp, maximum 48.6 A
Recommended input fuse IEC 50 A gG; UL 60 A Class T
Typical heat dissipation 528 W
Cooling air flow 179 m3/h (105 ft3/min), max. noise 76 dBA
Maximum recommended motor cable 300 m
Dimensions, IP21 standard 490 mm with glandbox x 203 x 229 mm
Weight, IP21 standard 11.8 kg
Standard enclosure IP21 / UL Type 1

Overload, fuse and cooling data for the ACS580-01-039A-4

The catalogue splits the rating into two duty classes. Light duty is 36.1 A (18.5 kW) with a 110% overload for 60 seconds, roughly 39.7 A. Heavy duty is 31.6 A (15 kW) with 150% for 60 seconds, roughly 47.4 A. The maximum output current of 56.9 A is available for 2 seconds at start. Check the load profile against these figures.

Cabinet designers should allow 528 W and 179 m3/h of air flow. Maximum recommended motor cable is 300 m, and the catalogue fuse is 50 A gG (60 A UL Class T). If the load turns out to be 15 kW or less, ACS580-01-033A-4 may fit (32 A); above 22 kW the next type is ACS580-01-046A-4 at 45 A.

How to read the type code

An order for this drive starts with ACS580-01-039A-4. In that string 01 is wall-mounted, 039A is the catalogue rating and 4 the voltage class. ABB prints these plus codes: +B056 IP55 / UL Type 12, +B063 IP66 / UL Type 4X, +F278 main switch (R1 to R5), +E223 C1 filter (R1 to R5), +C135 flange mounting, +P944 conduit box removal (R5 to R9).

Wet or dusty site? ABB lists +B056 for IP55, and frame R3 then measures 490 (733 with options +F287, +F316 or +E223) x 206 x 237 mm. IP66 / UL Type 4X (+B063) measures 647 x 277 x 260 mm, 26.4 kg. Network adapters such as FPBA-01, FSCA-01, FEIP-21 and FMBT-21 plug in with codes +K454, +K458, +K490 and +K491.

Key features of the ACS580-01-039A-4

  • Built-in DC choke for reduced input harmonics, so no separate line reactor is normally needed.
  • Integrated EMC filter and embedded Modbus RTU on the control board, with optional fieldbus adapters for other networks.
  • Safe Torque Off as standard for machine safety functions.
  • Assistant control panel with set-up wizards and a Bluetooth panel option for commissioning from a phone.
  • Energy optimizer and energy calculators that show savings against direct-on-line operation.
  • Coated circuit boards as standard, which help in humid or dusty environments.

Choosing the duty class

Centrifugal pumps and fans have a load torque that rises with speed, so the light-duty rating of 36.1 A (18.5 kW) is normally the right comparison for these machines. Positive displacement pumps, loaded conveyors, mixers and crushers can demand high torque at low speed and during starting, and for those the heavy-duty current of 31.6 A (15 kW) should be compared with the motor current. If an 18.5 kW motor drives a constant-torque load, the next larger ACS580 rating is often the better choice. The decision should always be based on the motor nameplate current and the expected overload profile rather than on the power figure alone.

Installation and maintenance

  • Mount the drive vertically with the free space above and below that ABB specifies for frame R3, so cooling air can reach the 179 m³/h fan.
  • Use symmetrical shielded motor cable and 360° earthing of the shield at the glandbox for EMC compliance.
  • Protect the supply with the recommended 50 A gG fuses (IEC) or the UL fuse equivalent.
  • Replace the cooling fan and check capacitors according to the maintenance intervals in the hardware manual.
  • Back up drive parameters to the control panel or a PC before any service work.

Applications in Oman and GCC facilities

An 18.5 kW drive of this type often controls booster pumps in building water systems, cooling tower fans, chilled water pumps in district cooling and transfer pumps in water treatment. In these duties the variable speed control saves energy compared with throttling valves or dampers, which is significant where air conditioning loads dominate summer electricity use. The IP21 enclosure is intended for clean electrical rooms; for outdoor or dusty pump houses, the drive should be installed inside a suitably rated, ventilated or cooled cabinet. The 528 W typical heat dissipation is the figure to use when sizing panel cooling, and high ambient temperatures may require derating according to the hardware manual.

What to include in your RFQ

  • Type code ACS580-01-039A-4 and quantity, plus any option codes such as a higher enclosure class.
  • Motor nameplate data and the type of load (pump, fan, conveyor).
  • Fieldbus requirement, if not Modbus RTU.
  • Accessories such as a Bluetooth control panel, door mounting kit or output filters.
  • Delivery site and project documentation needs.

Datasheet and quotation

The linked catalogue, ABB document 3AUA0000145061, is the reference for every rating on this page. Seven Star LLC supplies the ACS580-01-039A-4 to project and maintenance buyers on request; a quotation lists availability and lead time once we have your duty details.

Always check the type code, options, motor current and ambient conditions against your own documents before ordering, since catalogue ratings apply at 40 degrees C and altitudes up to 1000 m.

Datasheets & Documents
  • PDF Catalog ABB ACS580 General Purpose Drives Catalog (3AUA0000145061) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

ABB, formed in 1988 and headquartered in Zurich, covers an unusually long stretch of a plant's equipment list, from the flowmeter and analyzer in the field to the drive, breaker and protection relay in the electrical room.

Seven Star LLC is an independent supplier serving Oman and the GCC. Our ABB listing concentrates on measurement and analytics: ABB flowmeters, liquid analysis sensors and systems, level and pressure instruments. It also includes valve actuators, low voltage circuit breakers, ABB drives, soft starters and protection relays.

ABB product families on this page

Flow measurement includes ABB electromagnetic, Coriolis, vortex and swirl meters, sold under names such as ProcessMaster, AquaMaster, CoriolisMaster and SwirlMaster. Liquid analysis covers pH, conductivity and dissolved oxygen sensors with their transmitters. SensyTemp TSP sensors handle temperature. On the electrical side the listing has ACS355 machinery drives, the ACS550 general purpose drive, the ACQ580 for water and wastewater and the ACS880-01 industrial drive, with fieldbus adapters such as the FPBA-01 for PROFIBUS DP. Protection and switching products include SACE Tmax XT molded case breakers, SACE Emax 2 air circuit breakers, PSR soft starters and the REM615 and RET615 relays.

Where ABB instruments and drives are used

Water and wastewater plants use the electromagnetic flowmeters, analyzers and ACQ580 drives together. Oil and gas, power and chemical plants specify the Coriolis and vortex meters, pressure and level transmitters and the 615 series relays for motor and transformer feeders. The drives run pumps, fans, conveyors and compressors in almost every industry.

Ordering ABB parts: what we need

For drives send the full type code from the rating label, for example ACS355-03E-05A6-4, plus the serial number if it is a replacement. For instruments send the complete order code, measuring span, process connection, wetted materials, output or protocol and the hazardous area approval. For breakers give frame size, rated current, breaking capacity, number of poles, trip unit and fixed or withdrawable version.

Frequently Asked Questions

What nominal current does the ACS580-01-039A-4 have?
The catalogue lists 38 A at 400 V in no-overload use for 18.5 kW, with 36.1 A light duty and 31.6 A heavy duty.
What fuse does ABB recommend for the ACS580-01-039A-4?
The catalogue recommends 50 A gG fuses for IEC installations and 60 A UL Class T fuses.
How much heat and cooling air does the ACS580-01-039A-4 need?
The catalogue gives a typical heat dissipation of 528 W and 179 m3/h (105 ft3/min) of cooling air, with a maximum noise level of 76 dBA.
Which frame size and weight is the ACS580-01-039A-4?
It is frame R3, 490 mm with glandbox x 203 x 229 mm in IP21 form, weighing 11.8 kg.
How is the IP55 version of the ACS580-01-039A-4 ordered?
Add the option code +B056 to the type designation. The catalogue lists +B056 as the IP55 / UL Type 12 unit for frames R1 to R9.