Brand: Micro Motion
Micro Motion H-Series Hygienic Coriolis Flow and Density Meters
Description
Hygienic Coriolis meters with polished 316L wetted parts
The Micro Motion H-Series is a hygienic Coriolis family for sanitary process control. Wetted parts are 316L stainless steel with a 30 Ra (0.76 µm) finish on the S models or a 15 Ra (0.38 µm) finish on the F models, in a compact, self-draining design for CIP and SIP. The datasheet quotes up to ±0.05 percent liquid mass flow accuracy and ±0.5 kg/m3 density accuracy and lists ASME BPE, EHEDG and 3-A hygienic standards.
Technical specifications
| Parameter | Specification |
|---|---|
| Datasheet | PS-00599, Rev U, June 2025 |
| Sensor models | H025, H050, H100, H150, H200, H300, H400; suffix S = 30 Ra, F = 15 Ra finish |
| Liquid mass and volume flow accuracy | ±0.05% premium; ±0.1% enhanced; ±0.15% basic |
| Liquid repeatability | 0.025% / 0.05% / 0.075% |
| Liquid density accuracy | ±0.5 / ±1 / ±2 kg/m3; density range up to 3,000 kg/m3 |
| Gas mass flow accuracy | ±0.35% of rate or ±0.5% of rate depending on level; repeatability ±0.25% |
| Maximum flow rate | H025 2,720 kg/h; H050 8,160; H100 32,650; H150 54,431; H200F 63,960 and H200S 87,100; H300 277,601; H400 436,000 kg/h |
| Nominal line size | H025 0.25 to 0.5 in; H050 0.5 to 1 in; H100 1 to 2 in; H150 1.5 in; H200 2 to 3 in; H300 3 to 4 in; H400 4 to 6 in |
| Maximum working pressure | 1,015 psig (70 barg) for all S and F models |
| Sensor weight | H025 6 kg; H050 7; H100 10; H150 12; H200 19; H300 48; H400 82 kg (CL150 flange, without electronics) |
| Hazardous area | CSA, ATEX Ex ib and Ex nA, IECEx, NEPSI; sensor and transmitter IP66/67 |
| Standards | ASME BPE, EHEDG, 3-A, ASME B31.3, PED, Dual Seal, SIL2 and SIL3 |
| Manufacturer warranty | 18 months as standard |
Choosing between sizes and finishes
Each model covers a band of line sizes, so the usual route is to pick the sensor by flow and pressure drop and then choose the hygienic fitting. The 15 Ra F models suit the most demanding hygiene specifications, while the 30 Ra S models cover general sanitary duty. The sensor can be fitted with the same MVD transmitter options as other Micro Motion sensors, including 2200S, 2400S, 1700/2700 and 3700 housings with IP66 to IP69K ratings depending on the model. Smart Meter Verification is included as standard, and flow range detection and other health diagnostics are licensed options. For a straight-tube alternative see the Micro Motion G-Series for compact duty or the Micro Motion T-Series datasheet for titanium straight-tube designs.
The case is a separate pressure boundary. The datasheet lists maximum case working pressure with a safety factor of four on burst: H025 471 psig (32 barg), H050 383 psig (26 barg), H100 320 psig (22 barg), H150 201 psig (14 barg), H200 190 psig (13 barg), H300 417 psig (29 barg) and H400 241 psig (17 barg). If process pressure is far above the case rating, consider a rupture disk, and note that fitting one means the case can no longer act as secondary containment.
What to confirm before ordering
- Product, flow range, viscosity and CIP or SIP conditions
- Sensor size and finish (S or F) and the hygienic fitting type and size
- Transmitter, outputs and hazardous area approval
- The hygienic documentation needed (3-A, EHEDG or ASME BPE), since not every option meets all listings
- Material and corrosion compatibility with cleaning chemicals
How the Micro Motion H-Series works
A Coriolis meter has tubes that vibrate. When liquid flows through them, the tubes twist slightly, and sensors measure the twist. The twist is proportional to the mass flow. The vibration frequency also changes with the density of the liquid, so one meter reports both mass flow and density. The H-Series is built with smooth, self-draining tubes for sanitary lines.
Where the Micro Motion H-Series is used
- Food and beverage lines
- Dairy and sanitary process lines
- Pharmaceutical and biotech processes
- Clean-in-place and steam-in-place systems
- Batching and filling
Selection checklist for the Micro Motion H-Series
- Model size from H025 to H400
- Finish: 30 Ra (S) or 15 Ra (F)
- Flow range and line size
- Accuracy level: premium, enhanced or basic
- Density range
- Working pressure up to 70 barg
- Hygienic fitting type
- Transmitter housing and hazardous area rating
Installation, commissioning and maintenance notes for the Micro Motion H-Series
Mount the sensor so that it drains fully and that the process can fill it without air pockets. Support the pipe so the sensor carries no pipe load. Connect the transmitter and set the flow range. Zero the meter with the line full and the flow stopped. Use Smart Meter Verification to check the health of the meter at intervals.
Requesting a quotation for the Micro Motion H-Series
Please send the model, the finish, the fittings, the transmitter and the quantity. Seven Star LLC serves industrial customers in Oman and the GCC and replies with a quotation based on the information provided.
Micro Motion H-Series wetted parts
The wetted parts are 316L stainless steel with a polished finish.
Micro Motion H-Series flow accuracy
Liquid mass flow accuracy is plus or minus 0.05 percent for premium, 0.1 percent for enhanced and 0.15 percent for basic.
Micro Motion H-Series density accuracy
Density accuracy is plus or minus 0.5, 1 or 2 kg/m3, depending on the level.
Micro Motion H-Series maximum flow
The H025 handles 2,720 kg/h and the H400 handles 436,000 kg/h.
Micro Motion H-Series weight
The sensor weight ranges from 6 kg for the H025 to 82 kg for the H400.
Micro Motion H-Series hygienic standards
The data sheet lists ASME BPE, EHEDG and 3-A standards.
Meter records for the Micro Motion H-Series
Record the zero value, the verification results and the date of each check.
Choosing the right Micro Motion H-Series size
Choose the sensor by flow and pressure drop, then pick the hygienic fitting.
Documents and quotation
The Micro Motion H-Series datasheet (PS-00599 Rev U, June 2025) is available from the product documents on this page. Seven Star LLC is an independent supplier in Muscat; send the complete order code from the nameplate or your specification and we will check it against the manufacturer documentation before quoting. Browse more flowmeters in the catalogue.
Datasheets & Documents
- Datasheet Micro Motion H-Series datasheet PS-00599 Rev U (June 2025) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Coriolis flow and density meters have carried the Micro Motion name since 1977, when the company started in Boulder, USA. A Coriolis meter measures mass flow directly and reads density from the same tubes. Seven Star LLC, an independent supplier in Oman, lists the Micro Motion ELITE CMF400 Coriolis flow and density meter and the compact G-Series, and sources Micro Motion flow meters by complete model code.
Micro Motion meter families
ELITE is the manufacturer's top performance family for flow and density, and the CMF400 is one of its larger line sizes. The G-Series is a newer, very compact family for general duty. Each sensor is paired with a Coriolis transmitter, and the range also includes density and viscosity meters. Liquids, gases and slurries can all be measured, which is why these meters appear in oil and gas, refining, chemical, food and marine service.
Ordering Micro Motion meters: what we need
A Micro Motion sensor and its transmitter each have their own model code and serial number; send both. For a new meter we need the fluid, flow range, density, viscosity, operating pressure and temperature, line size, process connection and rating, wetted material, hazardous area approval, outputs and protocol. Custody transfer duty in the GCC should be stated up front because it changes the approvals and calibration options requested.
Browse Micro Motion products by category: Flowmeters.
Related products
Frequently Asked Questions
S is 316L stainless steel with a 30 Ra (0.76 µm) finish and F is 316L with a 15 Ra (0.38 µm) finish, for example H100S or H100F.
The datasheet lists ASME BPE, EHEDG and 3-A, plus design for CIP and SIP; confirm which apply to the selected fitting.
All H-Series S and F sensors have a maximum working pressure of 1,015 psig (70 barg).
Up to ±0.05% mass and volume flow and ±0.5 kg/m3 density at the premium level, with ±0.1% and ±0.15% levels below it.
Smart Meter Verification is included as standard, with licensed options such as flow range detection; the check takes under 90 seconds.