Brand

Met One Instruments

Met One Instruments is an American maker of ambient air quality and meteorological instruments, best known for its BAM beta attenuation mass monitors and its laser-scattering particle counters and profilers. The company was founded in 1989 in Grants Pass, Oregon, with the stated aim of simplifying and improving the user’s experience, and it grew by adding products, services and acquisitions until it became a global supplier. Since 2021 Met One Instruments has operated as part of the Acoem Group, with its head office still in Grants Pass.

Read the full brand profile
  • 2 products
  • 1 category

2 products

Brand profile

About Met One Instruments

All brands →
Founded
1989
Headquarters
Grants Pass, Oregon, USA
Speciality
Ambient air quality and meteorological instruments
Listed with us
2 products

Met One Instruments products by category

Met One Instruments is an American maker of ambient air quality and meteorological instruments, best known for its BAM beta attenuation mass monitors and its laser-scattering particle counters and profilers. The company was founded in 1989 in Grants Pass, Oregon, with the stated aim of simplifying and improving the user’s experience, and it grew by adding products, services and acquisitions until it became a global supplier. Since 2021 Met One Instruments has operated as part of the Acoem Group, with its head office still in Grants Pass.

Met One Instruments company profile

Founded 1989
Headquarters Grants Pass, Oregon, USA
Ownership Part of the Acoem Group since 2021
Core technology Beta attenuation mass monitoring and laser light-scatter particle counting and profiling, plus meteorological sensors
Typical applications Ambient air quality networks, fenceline and dust monitoring, cleanrooms and indoor air quality, emergency response, weather stations
Standards Registered ISO 9001:2015 company; BAM-1020 holds US-EPA equivalent method designations for PM10, PM2.5 and PM10-2.5

Milestones

  • 1989: Met One Instruments, Inc. is founded with a focus on ease of use and customer service.
  • Mid-1990s: The company develops its Beta Attenuation Mass (BAM) monitor technology, widening its focus to air particle monitoring.
  • BAM-1020 designations: The BAM-1020 becomes the first instrument to receive a US-EPA Federal Equivalent Method designation for continuous PM2.5 monitoring, alongside its PM10 designation.
  • 2021: Met One Instruments joins the Acoem Group, gaining access to gas analysers, noise and vibration monitors and emission monitoring technology.
  • Today: BAM monitors are installed at US Embassies and Consulates around the world, and thousands of BAM 1020 units are deployed worldwide.

How a Met One Instruments beta attenuation monitor works

A BAM monitor draws ambient air through a strip of glass fibre filter tape at a controlled flow, typically 16.7 litres per minute. Particles collect on the tape while a small carbon-14 source sends beta rays through it to a scintillator and photomultiplier detector. The more mass sits in the beam, the more the rays are attenuated, and that attenuation is converted into a concentration in micrograms per cubic metre. Because attenuation depends on mass rather than on colour, shape or chemistry, the method treats diesel soot, road dust and sea salt alike, and it is accepted for regulatory use. The tape advances automatically, and a controlled inlet heater limits the effect of humidity on the sample. When a faster view is enough, Met One Instruments uses laser light scatter instead, which gives size-resolved particle data in seconds. Choose beta attenuation for compliance and reference work, and optical sensors for coverage, profiling and screening.

Where Met One Instruments products are used in Oman and the GCC

Air quality stations near ports, cement plants and refineries, fenceline dust monitoring at construction and mining sites, indoor air and cleanroom checks in hospitals and laboratories, and weather masts at industrial facilities all use this type of equipment. The humid coast and dust-laden interior make continuous, well-heated sampling and reliable calibration particularly important in the region.

Met One Instruments models we list

Family Examples
Beta attenuation mass monitors BAM-1020, BAM-1022
Particulate profilers and dust monitors ES-405, ES-642
Handheld particle counters and mass monitors 804, Aerocet 831
Meteorological sensors 034E

Ordering Met One Instruments products: what we need

Send the exact model, for example BAM-1020 or ES-642, with the quantity and delivery location. For monitors, also tell us the size fraction or designation you need (PM10, PM2.5 or PM10-2.5), the supply voltage, and any inlets, cyclones, filter tape, cables or software. For replacement and spare parts, include the instrument serial number. Seven Star LLC is an independent supplier serving Oman and the GCC, and we reply to each RFQ with availability and lead time.

Facts checked against the Met One Instruments company page and published Met One datasheets, November 2026.

Request a Quote for Met One Instruments Products

Looking for Met One Instruments parts not listed here, or pricing for a project? Send us the part numbers and quantities. Seven Star LLC sources genuine Met One Instruments products for customers across Oman and the GCC and replies with a formal quotation.

Free, no-obligation quotation · takes about 1 minute

Other enquiries: [email protected] · WhatsApp

FAQ

Questions about Met One Instruments

Common questions about Met One Instruments equipment, part numbers and supply to Oman and the GCC.

01What is a BAM monitor and why is it used for regulatory air quality work?
A BAM (beta attenuation mass) monitor measures particulate mass by comparing how much beta radiation from a carbon-14 source is absorbed by a clean and a dust-loaded spot of filter tape. The BAM-1020 holds US-EPA equivalent method designations for PM10, PM2.5 and PM10-2.5.
02Which Met One Instruments model suits portable PM2.5 monitoring?
The BAM-1022 is a real-time portable beta attenuation monitor with US-EPA Class III FEM designation EQPM-1013-209 for PM2.5. It has an integrated weatherproof enclosure and works from minus 30 to plus 50 C.
03How do the ES-405 and the Aerocet 831 differ?
Both report PM1, PM2.5, PM4, PM10 and TSP together. The ES-405 is a weatherproof fixed profiler with active flow control, a sheath air stream and RS-485, RS-232 and USB outputs, while the Aerocet 831 is a 0.79 kg battery-powered handheld with a 0 to 1,000 microgram range.
04What outputs does the ES-642 remote dust monitor provide?
The ES-642 provides 4-20 mA and 0-10 VDC analog outputs, RS-485 and RS-232 with MODBUS RTU or ASCII, and a relay alarm. It measures 0 to 100 mg per cubic metre and runs from 15 to 40 VDC.
05Which Met One Instruments product counts particles for cleanroom checks?
The 804 handheld counter has four selectable channels from 0.3 to 10 microns, reports in as little as 3 seconds and stores 2,500 records. It ships with a NIST traceable calibration certificate.