Servomex S1200922 CW Boss Scrubber H2O/CO2 for SpectraExact 2500
Description
What Servomex S1200922 does inside the 2500
Servomex S1200922 is the detector and cell boss scrubber marked CW, listed in Table 6.6 of the SpectraExact 2500 series manual with the description H2O/CO2. In a 2500 the sample cell is supported between the two end castings by short bosses, which may be scrubbed or purged. Gases that sit in those boss volumes, water vapour and carbon dioxide above all, can absorb in the same infrared bands as the measured component and so cause cross interference. A scrubber is a small metal housing packed with chemically active material that removes the troublesome gas.
This page helps buyers choose between three markings. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
The chemistry behind the CW scrubber
The manual states that a number of materials are available: molecular sieve to absorb water vapour, soda lime for carbon dioxide and Hopcalite for carbon monoxide. The CW marking denotes the water and carbon dioxide mix. When a 2500 is specified, the right scrubber is stipulated and the analyser is delivered with scrubbers fitted, so a replacement must always be of the correct type.
| Parameter | Value |
|---|---|
| Part number | S1200922 |
| Marking | CW |
| Absorbs | H2O and CO2 |
| Table | 6.6 Scrubber Spares |
| Sibling W | S1200921, H2O |
| Sibling H | S1200924, H2O/CO2/CO |
| Sachet kits | S2000510 H2O mix; S2000511 H2O/CO2 mix; S2000512 H2O/CO2/CO mix |
| Recommended stock | 2 per 1 to 3 analysers, 4 per 4 to 9 analysers, for 2 years |
| Storage | Unopened packing, airtight container or desiccator |
| Use order | First in, first out |
How S1200922 differs from related parts
- S1200921 (W): water only, for gases where CO2 is part of the measurement and must not be removed.
- S1200922 (CW): water and carbon dioxide, for analyses where neither gas is the target.
- S1200924 (H): water, carbon dioxide and carbon monoxide.
- S2000511: the loose sachet material of the same mix for refilling.
Handling instructions in the manual
When the analyser is dismantled the scrubbers must not be left exposed to normal atmosphere for more than a few minutes or they will be exhausted. After long-term use they may need replacement. When refitting a cell, the end bosses should be briefly flushed with clean dry nitrogen after the cell is mounted, then the new absorbent scrubbers are quickly screwed in. Scrubbers should be used as soon as received, otherwise stored sealed, in an airtight container or desiccator.
When to change the scrubber
Signs include drifting zero or reference signals that move with the plant atmosphere. Also change the scrubbers whenever the cell is removed for cleaning. The recommended spares table lists chopper box scrubbers and detector and cell boss scrubbers separately, each as refer to application.
Purges, vents and flammable samples
A scrubber is not a safety device. For flammable, severely corrosive or toxic samples the manual describes end boss vents and special window and O ring inserts that vent the sample to atmosphere if a window fails, and states that sealing the end bosses with scrubbers when measuring a flammable sample would be wrong. If your analyser is such a version, confirm that the scrubber is allowed before ordering.
Ordering notes for S1200922
State the marking printed on the old scrubber, the analyser serial number and the quantity. Pair with a cell seals kit if the cell is being opened.
To judge the stock needed, use the manual recommendation for two years: two chopper box scrubbers and two detector and cell boss scrubbers for one to three analysers, and four of each for four to nine analysers. The note attached warns that scrubbers should be used as soon as received, or stored in their sealed unopened packaging in an airtight container, preferably a desiccator, and used on a first in, first out basis.
Mounting position matters: scrubbers screw into the bosses at each end of the cell, and the manual describes the sequence of flushing with clean dry nitrogen, then quickly fitting the new scrubbers, then tightening the screws holding the source end casting to the chassis if they were loosened. Take care when working near the heated cell, whose surface temperature can reach or exceed 100 degrees Celsius.
A practical tip from the table of fault messages: if the zero drifts only after the cell has been serviced, the scrubbers or the nitrogen flush of the bosses are the first things to review, before replacing electronics. The recommended routine of flushing with dry nitrogen is intended to remove the ambient water and carbon dioxide that would otherwise load the new CW material at once.
Seven Star LLC can quote the loose sachet kit S2000511 together with this scrubber housing if the site refills its own scrubbers.
For purchasing, quote S1200922 together with its CW marking, state how many scrubbers are required at each end of the cell, and confirm whether the chopper box scrubbers are also due. Each S1200922 should be installed immediately after opening, and the old unit labelled and discarded since its absorbent is spent. If S1200922 is being fitted to an analyser for the first time after a process change, ask the engineering team to verify that CW is still the right marking for the new background gas.
Documents and quotation
The Servomex SpectraExact 2500 series manual, part number 02500005D, is the document we attach for Servomex S1200922; its section 6 spares tables are the source of the part number and description. Please state the scrubber marking on your existing unit (W, CW or H) so we can confirm the exact part. To request a quotation, send S1200922, the quantity, the analyser serial number and the Final Specification Sheet reference if you have it, and your delivery location in Oman or the GCC. Each RFQ is answered with availability and lead time.
Other Models in the Servomex 2500 Range
Seven Star LLC supplies models from the Servomex 2500 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Servomex S2500931A Long Wave ZnSe Source Unit for SpectraExact 2500 | Gas Analyzer Systems | View details |
| Servomex S2501905C CVDFET Detector Unit for SpectraExact 2500 | Gas Analyzer Systems | View details |
| Servomex S2500980B BaF2 Window for SpectraExact 2500 | Gas Analyzer Systems | View details |
| Servomex S1200922 CW Boss Scrubber H2O/CO2 for SpectraExact 2500 | Gas Analyzer Systems | You are viewing this model |
Datasheets & Documents
- Datasheet Servomex S1200922 CW Boss Scrubber H2O/CO2 for SpectraExact 2500 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Servomex is a British specialist in gas analysis, founded in 1952 by Richard Steel, John Crockett and Ronald Mudie; the name comes from servomechanism. It first made electronic products, then built its first paramagnetic oxygen analyser in 1961 after work with Charles Munday on a paramagnetic sensor. Servomex is based in Crowborough, East Sussex, and is part of Spectris.
Seven Star LLC lists Servomex process, combustion, emissions and portable gas analyzers, plus accessories, and sources them for refineries, petrochemical plants and industrial gas producers in Oman.
SERVOMEX company profile
| Founded | 1952, United Kingdom |
|---|---|
| Founders | Richard Steel, John Crockett and Ronald Mudie |
| Headquarters | Jarvis Brook, Crowborough, East Sussex |
| Ownership | Spectris plc, since 1999 |
| Key technologies | Paramagnetic oxygen sensing (1961), infrared analysis (1969), zirconia oxygen sensors (1981) |
| Product families | MultiExact and SERVOPRO MultiExact analysers, SERVOTOUGH OxyExact and Oxy 1800 oxygen analysers, SERVOTOUGH Laser 3 Plus TDL analysers, SERVOFLEX portable analysers, zirconia combustion analysers |
Milestones
- 1952: Servomex is founded.
- 1961: The first Servomex paramagnetic oxygen analyser is introduced.
- 1981: Servomex introduces zirconia oxygen sensors.
- 1999: Spectris acquires Servomex.
Servomex analyzer families listed
Servomex groups its analyzers under family names that indicate where they can be used. SERVOTOUGH covers analyzers built for hazardous areas and field mounting, SERVOPRO covers units for general purpose areas and analyzer houses, and SERVOFLEX is the portable line. On this page:
- SERVOTOUGH OxyExact 2200: paramagnetic oxygen analyzer for process control and safety
- SERVOTOUGH SpectraExact 2500: photometric analyzer for process gas components
- SERVOTOUGH Laser 3 Plus: compact tunable diode laser analyzer for combustion
- SERVOPRO 4900 Multigas: multi-component analyzer for emissions monitoring
- SERVOPRO NanoTrace DF-550E: ultra-trace oxygen analyzer for high purity gases
- SERVOFLEX Micro i.s. 5100: intrinsically safe portable oxygen analyzer
A flow alarm relay box for the 2700 flue gas analyzer is also listed.
Where Servomex gas analyzers are used
Typical duties are oxygen measurement for inerting and blanketing, vapor recovery and flare header safety, combustion control on fired heaters and reformers, purity control in air separation and electronic gases, and continuous emissions monitoring. In the GCC the main users are refining, petrochemicals, fertilizer, LNG and industrial gas plants.
SERVOMEX products we list
Ordering Servomex analyzers and spares: what we need
A Servomex gas analyzer is built to an order code that fixes the measured gas, range, sample wetted materials, outputs and hazardous area approval. For replacements and spare parts, send the model, the serial number and the order code from the data plate. For a new Servomex oxygen analyzer or multigas unit, send the full stream composition, the component and range to be measured, sample pressure and temperature, the area classification, power supply and communication needs. We check the configuration against Servomex documentation before quoting.
Facts checked against Servomex's own 70-year history and company profiles, October 2026.
Browse SERVOMEX products by category: Gas Analyzer Systems, Gas Analyzer Accessories, Portable Test & Measurement.
FAQ
Questions about the Servomex S1200922 CW Boss Scrubber H2O/CO2 for
Answers from our engineering team on installation, compatibility and integration.
01What does Servomex S1200922 remove?
It is the detector and cell boss scrubber marked CW, intended for water vapour and carbon dioxide (H2O/CO2).
02How does it differ from S1200921 and S1200924?
S1200921, marked W, handles H2O; S1200924, marked H, handles H2O, CO2 and CO.
03How long may a scrubber stay exposed to air?
The manual says not more than a few minutes during dismantling or the material will be exhausted.
04How should scrubbers be stored?
In unopened sealed packaging in an airtight container, preferably a desiccator, used first in first out.
05What materials are used in scrubbers?
The manual lists molecular sieve for water vapour, soda lime for carbon dioxide and Hopcalite for carbon monoxide.